The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Open accessAbstract
Rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques. Fluorescence was monitored by (i) the double-strand-specific dye SYBR Green I, (ii) a decrease in fluorescein quenching by rhodamine after exonuclease cleavage of a dual-labeled hydrolysis probe and (iii) resonance energy transfer of fluorescein to Cy5 by adjacent hybridization probes. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy number. The sensitivity of SYBR Green I detection is limited by nonspecific product formation. Use of a single exonuclease hydrolysis probe or two adjacent hybridization probes offers increasing levels of specificity. In contrast to fluorescence measurement once per cycle, continuous monitoring throughout each cycle monitors the temperature dependence of fluorescence. The cumulative, irreversible signal of hydrolysis probes can be distinguished easily from the temperature-dependent, reversible signal of hybridization probes. By using SYBR Green I, product denaturation, annealing and extension can be followed within each cycle. Substantial product-to-product annealing occurs during later amplification cycles, suggesting that product annealing is a major cause of the plateau effect. Continuous within-cycle monitoring allows rapid optimization of amplification conditions and should be particularly useful in developing new, standardized clinical assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Livak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Resonance Energy Transfer: Methods and Applications
Wu, P. G., & Brand, L. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1134 · Cited by 1,277
Simultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G., Walsh, P. S., & Griffith, R. (1992) · Bio/Technology · doi:10.1038/nbt0492-413 · Cited by 1,130
Barnes, W. M. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.6.2216 · Cited by 1,034
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Self-citationAllelic discrimination by nick-translation PCR with fluorgenic probes
Lee, L. G., Connell, C. R., & Bloch, W. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.16.3761 · Cited by 749
Minimizing the time required for DNA amplification by efficient heat transfer to small samples
Wittwer, C. T., Fillmore, G. C., & Garling, D. J. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90090-v · Cited by 203
Self-citationAutomated polymerase chain reaction in capillary tubes with hot air
Wittwer, C. T., Fillmore, G. C., & Hillyard, D. R. (1989) · Nucleic Acids Research · doi:10.1093/nar/17.11.4353 · Cited by 170
Self-citation[4] Large- and small-scale phenol extractions
Wallace, D. M. (1987) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(87)52007-9 · Cited by 126
Development of a sensitive reverse transcriptase PCR assay, RT-RPCR, utilizing rapid cycle times.Preprint
Tan, S. S., & Weis, J. H. (1992) · Genome Research · doi:10.1101/gr.2.2.137 · Cited by 71
Wittwer, C. T., Reed, G. B., & Ririe, K. M. (1994) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-0257-8_15 · Cited by 67
Self-citationRapid cycle allele-specific amplification: studies with the cystic fibrosis delta F508 locus
Wittwer, C. T., Marshall, B. C., Reed, G. H., & Cherry, J. L. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.5.804 · Cited by 47
Self-citationEffect of heat denaturation of target DNA on the PCR amplification
Gustafson, C. E., Alm, R. A., & Trevor J. TRUST (1993) · Gene · doi:10.1016/0378-1119(93)90130-u · Cited by 34
A method for accurate amplification of polymorphic CA-repeat sequences.Preprint
Odelberg, S. J., & White, R. L. (1993) · Genome Research · doi:10.1101/gr.3.1.7 · Cited by 31
Nuclear texture analysis: A new prognostic tool in metastatic prostate cancer
J�rgensen, T., Kanagasingam, Y., Tveter, K. J., Skj�rten, F., & Danielsen, H. E. (1996) · Cytometry · doi:10.1002/(sici)1097-0320(19960701)24:3<191::aid-cyto1>3.0.co;2-l · Cited by 27
Cited by
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationBustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
RNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Winer, J., Jung, C. K. S., Shackel, I., & Williams, P. M. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4085 · Cited by 1,387
Metadata
- Authors
- Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P.
- Venue
- BioTechniques
- Publisher
- Informa UK Limited
- Published
- 2013-06
- Volume
- 54
- Issue
- 6
- Pages
- 314-320
- ISSN
- 0736-6205 (ISSN-L)
- 1940-9818
- OpenAlex
- W1594653092
- Cited by
- 1,274
- References
- 19
- FWCI
- 20.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.