Linear mRNA Amplification from as Little as 5 ng Total RNA for Global gene Expression Analysis
Open accessThe DOI matches its Crossref record.
Abstract
Gene expression analysis has become an invaluable tool for understanding gene function and regulation. However, global expression analysis requires large RNA quantities or RNA preamplification. We describe an isothermal messenger RNA (mRNA) amplification method, Ribo-SPIA, which generates micrograms of labeled cDNA from 5 ng of total RNA in 1 day for analysis on arrays or by PCR quantification. Highly reproducible GeneChip array performance (R2 > 0.95) was achieved with independent reactions starting with 5-100 ng Universal Human Reference total RNA. Targets prepared by the Ribo-SPIA procedure (20 ng total RNA input) or the Affymetrix Standard Protocol (10 microg total RNA) perform similarly, as indicated by gene call concordance (86%) and good correlation of differential gene expression determination (R2 = 0.82). Accuracy of transcript representation in cDNA generated by the Ribo-SPIA procedure was also demonstrated by PCR quantification of 33 transcripts, comparing differential expression in amplified and nonamplified cDNA (R2 = 0.97 over a range of nearly 10(6) infold change). Thus Ribo-SPIA amplification of mRNA is rapid, robust, highly accurate and reproducible, and sensitive enough to allow quantification of very low abundance transcripts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
RNA sequencing: advances, challenges and opportunities
Ozsolak, F., & Milos, P. M. (2011) · Nature Reviews Genetics · doi:10.1038/nrg2934 · Cited by 2,135
Solovei, I., Wang, A. S., Thanisch, K., Schmidt, C. S., Krebs, S., Zwerger, M., Cohen, T. V., Devys, D., Foisner, R., Peichl, L., et al. (2013) · Cell · doi:10.1016/j.cell.2013.01.009 · Cited by 809
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766
Regulation of Cell Cycle to Stimulate Adult Cardiomyocyte Proliferation and Cardiac Regeneration
Mohamed, T. M. A., Ang, Y.-S., Radzinsky, E., Zhou, P., Huang, Y., Elfenbein, A., Foley, A., Magnitsky, S., & Srivastava, D. (2018) · Cell · doi:10.1016/j.cell.2018.02.014 · Cited by 576
Nucleic Acid Isothermal Amplification Technologies—A Review
Gill, P., & Ghaemi, A. (2008) · Nucleosides, Nucleotides and Nucleic Acids · doi:10.1080/15257770701845204 · Cited by 534
Transcriptomics: Advances and approaches
Dong, Z., & Chen, Y. (2013) · Science China Life Sciences · doi:10.1007/s11427-013-4557-2 · Cited by 231
Bioanalytical applications of isothermal nucleic acid amplification techniques
Deng, H., & Gao, Z. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.09.037 · Cited by 213
Measurable impact of RNA quality on gene expression results from quantitative PCR
Vermeulen, J., De Preter, K., Lefever, S., Nuytens, J., De Vloed, F., Derveaux, S., Hellemans, J., Speleman, F., & Vandesompele, J. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr065 · Cited by 207
Novel Isothermal, Linear Nucleic Acid Amplification Systems for Highly Multiplexed Applications
Kurn, N., Chen, P., Heath, J. D., Kopf-Sill, A., Stephens, K. M., & Wang, S. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.053694 · Cited by 202
Self-citationIsothermal DNA Amplification in Bioanalysis: Strategies and Applications
Kim, J., & Easley, C. J. (2011) · Bioanalysis · doi:10.4155/bio.10.172 · Cited by 168
Chan, J. P., Cordeira, J., Calderon, G. A., Iyer, L. K., & Rios, M. (2008) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2008.07.017 · Cited by 161
“Others showed that RNA amplification does not result in a misrepresentation of the transcript composition of the original sample (Dafforn et al., 2004;Stoyanova et al., 2004).”
Yang, C., Guo, R., Jie, F., Nettleton, D., Peng, J., Carr, T., Yeakley, J. M., Fan, J.-B., & Whitham, S. A. (2007) · Molecular Plant-Microbe Interactions® · doi:10.1094/mpmi-20-4-0358 · Cited by 158
“The RNA samples (50 ng) then were amplified and labeled with the Ovation Biotin RNA Amplification and Labeling System (NuGEN Technologies, Inc. San Carlos, CA, U.S.A.) (Dafforn et al. 2004).”
Vartanian, K., Slottke, R., Johnstone, T., Casale, A., Planck, S. R., Choi, D., Smith, J. R., Rosenbaum, J. T., & Harrington, C. A. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-2 · Cited by 70
Metadata
- Authors
- Dafforn, A., Chen, P., Deng, G., Herrler, M., Iglehart, D., Koritala, S., Lato, S., Pillarisetty, S., Purohit, R., Wang, M., Wang, S., & Kurn, N.
- Venue
- BioTechniques
- Publisher
- Informa UK Limited
- Published
- 2004-11
- Volume
- 37
- Issue
- 5
- Pages
- 854-857
- ISSN
- 0736-6205 (ISSN-L)
- 1940-9818
- OpenAlex
- W1546953955
- Cited by
- 125
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.