The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Using bar-code technology and medication observation methodology for safer medication administration
Abstract
PURPOSE: The implementation of a multidisciplinary approach to systematically decrease medication errors through the use of observation methodology and the deployment of electronic medication administration records (EMARs) and bar-coded-medication administration (BCMA) is described. SUMMARY: For a consistent and reliable approach to data collection, a direct-observation technique was used. The measurement of medication errors using the observation process occurred in two phases-preimplementation and postimplementation. Three inpatient nursing units participated. The control group was a 20-bed cardiac telemetry unit. Intervention group 1 was also a 20-bed cardiac telemetry unit. Intervention group 2 was a 36-bed medical-surgical unit. During the first phase of the study, all three study groups participated in evaluating the medication administration process associated with a manual five-day medication administration record (MAR). A total of 188 errors were reported. The pharmacy, nursing, and information services departments collaborated on the design and deployment of the EMAR and BCMA systems. The systems were implemented in one nursing unit in August 2003, with full implementation on all inpatient units by July 2004. During the second phase of the study, the control group continued to use the manual five-day MAR without a change in the process. Intervention groups 1 and 2 were measured to evaluate the medication administration process using EMAR and BCMA technology. The direct-observation accuracy rate before BCMA was 86.5%; after BCMA, the rate rose to 97%. CONCLUSION: The direct-observation methodology was used to monitor medication administration before and after the deployment of the EMAR and BCMA systems. A 54% reduction of medication administration errors was observed following implementation of a multidisciplinary, collaborative approach to medication safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Comparison of methods for detecting medication errors in 36 hospitals and skilled-nursing facilities
Flynn, E. A., Barker, K. N., Pepper, G. A., Bates, D. W., & Mikeal, R. L. (2002) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/59.5.436 · Cited by 449
Cited by
Effect of Bar-Code Technology on the Safety of Medication Administration
Poon, E. G., Keohane, C. A., Yoon, C. S., Ditmore, M., Bane, A., Levtzion-Korach, O., Moniz, T., Rothschild, J. M., Kachalia, A. B., Hayes, J., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmsa0907115 · Cited by 588
Keers, R. N., Williams, S. D., Cooke, J., & Ashcroft, D. M. (2013) · Annals of Pharmacotherapy · doi:10.1345/aph.1r147 · Cited by 354
Ahtiainen, H. K., Kallio, M. M., Airaksinen, M., & Holmström, A.-R. (2020) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2018-001791 · Cited by 78
Oldland, A. R., Golightly, L. K., May, S. K., Barber, G. R., & Stolpman, N. M. (2015) · Hospital Pharmacy · doi:10.1310/hpj5001-34 · Cited by 25
Metadata
- Authors
- Paoletti, R. D., Suess, T. M., Lesko, M. G., Feroli, A. A., Kennel, J. A., Mahler, J. M., & Sauders, T.
- Venue
- American Journal of Health-System Pharmacy
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-03-01
- Volume
- 64
- Issue
- 5
- Pages
- 536-543
- ISSN
- 1079-2082 (ISSN-L)
- 1535-2900
- OpenAlex
- W2066218012
- Cited by
- 166
- References
- 2
- FWCI
- 16.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using bar-code technology and medication observation methodology for safer medication administration. https://app.cochat.ai/papers/10.2146/ajhp060140
- The paper
- Paoletti, R. D., Suess, T. M., Lesko, M. G., Feroli, A. A., Kennel, J. A., Mahler, J. M., & Sauders, T. (2007). Using bar-code technology and medication observation methodology for safer medication administration. American Journal of Health-System Pharmacy. https://doi.org/10.2146/ajhp060140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.