Using bar-code technology and medication observation methodology for safer medication administration

Paoletti, Richard D., Suess, Tina M., Lesko, Michael G., Feroli, Alfred A., Kennel, James A., Mahler, Joye M., Sauders, Timothy·2007·American Journal of Health-System Pharmacy

Abstract

PURPOSE: The implementation of a multidisciplinary approach to systematically decrease medication errors through the use of observation methodology and the deployment of electronic medication administration records (EMARs) and bar-coded-medication administration (BCMA) is described. SUMMARY: For a consistent and reliable approach to data collection, a direct-observation technique was used. The measurement of medication errors using the observation process occurred in two phases-preimplementation and postimplementation. Three inpatient nursing units participated. The control group was a 20-bed cardiac telemetry unit. Intervention group 1 was also a 20-bed cardiac telemetry unit. Intervention group 2 was a 36-bed medical-surgical unit. During the first phase of the study, all three study groups participated in evaluating the medication administration process associated with a manual five-day medication administration record (MAR). A total of 188 errors were reported. The pharmacy, nursing, and information services departments collaborated on the design and deployment of the EMAR and BCMA systems. The systems were implemented in one nursing unit in August 2003, with full implementation on all inpatient units by July 2004. During the second phase of the study, the control group continued to use the manual five-day MAR without a change in the process. Intervention groups 1 and 2 were measured to evaluate the medication administration process using EMAR and BCMA technology. The direct-observation accuracy rate before BCMA was 86.5%; after BCMA, the rate rose to 97%. CONCLUSION: The direct-observation methodology was used to monitor medication administration before and after the deployment of the EMAR and BCMA systems. A 54% reduction of medication administration errors was observed following implementation of a multidisciplinary, collaborative approach to medication safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2146/ajhp060140

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 166

Metadata

Authors
Paoletti, R. D., Suess, T. M., Lesko, M. G., Feroli, A. A., Kennel, J. A., Mahler, J. M., & Sauders, T.
Venue
American Journal of Health-System Pharmacy
Published
2007-03-01
Volume
64
Issue
5
Pages
536-543
ISSN
  • 1079-2082 (ISSN-L)
  • 1535-2900
OpenAlex
W2066218012
Cited by
166
References
2
FWCI
16.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using bar-code technology and medication observation methodology for safer medication administration. https://app.cochat.ai/papers/10.2146/ajhp060140
The paper
Paoletti, R. D., Suess, T. M., Lesko, M. G., Feroli, A. A., Kennel, J. A., Mahler, J. M., & Sauders, T. (2007). Using bar-code technology and medication observation methodology for safer medication administration. American Journal of Health-System Pharmacy. https://doi.org/10.2146/ajhp060140

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.