Developing and implementing clinical decision support for use in a computerized prescriber-order-entry system
The DOI matches its Crossref record; 27 of the 30 references it cites were found in a registry or an index.
Abstract
PURPOSE: The development and implementation of clinical decision support (CDS) in a computerized prescriber-order-entry (CPOE) system in a large, tertiary care, academic health care system are described. SUMMARY: CDS is generally considered to be a key factor in promoting successful system adoption, patient safety, and positive patient outcomes for CPOE implementation. The impact of CDS depends on the methods used by the institution to implement CPOE using both passive and active system design features. At the University of Michigan Health System, interdisciplinary project teams were assembled to plan, build, and implement the CDS component of CPOE using several underlying fundamental principles to ensure the usability and safety of the system, including standardization of system configuration, workflow design, and prioritization of the number and types of interruptive alerts that would be deployed. Passive CDS rules were established for nomenclature, links to information, relevant results, and order sets. Active CDS rules were developed for noninterruptive alerts (patient list alert flags and form-called medical logic modules) and interruptive alerts, including alerts for allergies, dose checks, drug-drug interactions, drug-food interactions, and drug-disease interactions. The institution provided sufficient staffing and institutional governance to implement and sustain CDS. CONCLUSION: Through an interdisciplinary collaboration, an academic health care system planned, designed, and implemented institution-specific, CPOE-integrated CDS to improve clinical efficiency and facilitate the compliance with regulatory policies and guidelines.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This is a common approach used in high-stakes decision support systems to increase the safety, speed and accuracy of the decision-making [21].”
From Explainable recommendation: when design meets trust calibration (2021) · cites this paper as [21]
In the citing paper
“In HCI literature, visual cues have been used to reduce overlooking specific part of the interface for high critical tasks [21, 62].”
From Explainable recommendation: when design meets trust calibration (2021) · cites this paper as [21]
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Schwartz, G. J., Haycock, G. B., Edelmann, C. M., & Spitzer, A. (1976) · Pediatrics · doi:10.1542/peds.58.2.259 · Cited by 2,379
Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Institute for Safe Medication Practices
Cohen, M. R. (2002) · Encyclopedia of Clinical Pharmacy · doi:10.3109/9780824706081.079 · Cited by 1,205
Poissant, L. (2005) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1700 · Cited by 901
Types of Unintended Consequences Related to Computerized Provider Order Entry
Campbell, E. M., Sittig, D. F., Ash, J. S., Guappone, K. P., & Dykstra, R. H. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2042 · Cited by 823
Computerized Physician Order Entry and Medication Errors in a Pediatric Critical Care Unit
Potts, A. L., Barr, F. E., Gregory, D. F., Wright, L., & Patel, N. R. (2004) · Pediatrics · doi:10.1542/peds.113.1.59 · Cited by 410
Research works printed but not linked: 1
- Thompson, 2005, Computerized physician order entry, a factor in medication errors: descriptive analysis of events in the intensive care unit safety reporting system, J Clin Outcomes Manage, 12, 404
Cited by
Horsky, J., Schiff, G. D., Johnston, D., Mercincavage, L., Bell, D., & Middleton, B. (2012) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.09.002 · Cited by 289
“, annual tests) or to increase regulatory compliance, quality assurance and administrative initiatives [20].”
Kohli, R., Devaraj, S., & Ow, T. T. (2012) · MIS Quarterly · doi:10.2307/41703502 · Cited by 174
“Some examples are computerized physician order entry (CPOE) systems (Chaffee and Zimmerman 2010), or adverse drug event (ADE) tracking systems and physician profiling systems (Piontek, et al.”
BackgroundDesign of decision support interventions for medication prescribing
Horsky, J., Phansalkar, S., Desai, A. A., Bell, D. S., & Middleton, B. (2013) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2013.02.003 · Cited by 119
“For example, generic drug names may always be rinted in lowercase letters while brand name equivalents ay have the first letter capitalized, giving a distinctive visual ue to items in each group [42].”
BackgroundInfluentialClinical Decision Support Systems for Drug Allergy Checking: Systematic Review
Légat, L., Van Laere, S., Nyssen, M., Steurbaut, S., Dupont, A. G., & Cornu, P. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.8206 · Cited by 94
Devine, E. B., Lee, C.-J., Overby, C. L., Abernethy, N. F., McCune, J. S., Smith, J. W., & Tarczy-Hornoch, P. Z. (2014) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2014.04.008 · Cited by 86
“Participants agreed with the idea of providing additional resources to guide drug dosing, and made use of the clinical knowledge resources behind the Infobutton and EVIDENCE icons to achieve this end (domain 2) [29].”
BackgroundMethod
Metadata
- Authors
- Chaffee, B. W., & Zimmerman, C. R.
- Affiliations
- Informatics and Outcomes, Department of Pharmacy Services
- Michigan Medicine (US)
- Corresponding author
- Chaffee, Bruce W.
- Venue
- American Journal of Health-System Pharmacy
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-03-01
- Volume
- 67
- Issue
- 5
- Pages
- 391-400
- ISSN
- 1079-2082 (ISSN-L)
- 1535-2900
- OpenAlex
- W2170730304
- Cited by
- 44
- References
- 30
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 2 · 2021: 2 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 4 · 2015: 4 · 2014: 8 · 2013: 6 · 2012: 6
- FWCI
- 10.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Health-System Pharmacy (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Technology and Human Factors in Education and Health
- Keywords
- clinical decision support, computerized physician order entry, interruptive alerts, drug-drug interactions, drug-disease interactions, food-drug interactions, order sets, workflow design, patient safety, system adoption, interdisciplinary collaboration
- MeSH terms
- Academic Medical Centers, Humans, Medication Errors, Quality Assurance, Health Care, Program Development, Decision Support Systems, Clinical, Medical Order Entry Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.