Recommendations for Improved Data Processing from Expired Gas Analysis Indirect Calorimetry
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
There is currently no universally recommended and accepted method of data processing within the science of indirect calorimetry for either mixing chamber or breath-by-breath systems of expired gas analysis. Exercise physiologists were first surveyed to determine methods used to process oxygen consumption ((.)VO2) data, and current attitudes to data processing within the science of indirect calorimetry. Breath-by-breath datasets obtained from indirect calorimetry during incremental exercise were then used to demonstrate the consequences of commonly used time, breath and digital filter post-acquisition data processing strategies. Assessment of the variability in breath-by-breath data was determined using multiple regression based on the independent variables ventilation (VE), and the expired gas fractions for oxygen and carbon dioxide, FEO2 and FECO2, respectively. Based on the results of explanation of variance of the breath-by-breath (.)VO2 data, methods of processing to remove variability were proposed for time-averaged, breath-averaged and digital filter applications. Among exercise physiologists, the strategy used to remove the variability in (.)VO2 measurements varied widely, and consisted of time averages (30 sec [38%], 60 sec [18%], 20 sec [11%], 15 sec [8%]), a moving average of five to 11 breaths (10%), and the middle five of seven breaths (7%). Most respondents indicated that they used multiple criteria to establish maximum ((.)VO2 ((.)VO2max) including: the attainme…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since Costill et al . [ 12 ] reported the improvement of physical performance after intake of caffeine, many studies have reported the same and claimed that ergogenic effect of caffeine was seen in people who had at least more than 2.5 mg/kg -1 . dose of caffeine intake [ 13 , 14 ].”
From Effect of energy drink dose on exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise (2014) · cites this paper as [14]
Citations
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Limiting factors for maximum oxygen uptake and determinants of endurance performance
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00012 · Cited by 2,410
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Maximal Oxygen Intake as an Objective Measure of Cardio-Respiratory Performance
Taylor, H. L., Buskirk, E., & Henschel, A. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.1.73 · Cited by 1,342
Muscular Exercise, Lactic Acid, and the Supply and Utilization of Oxygen
Hill, A. V., & Lupton, H. (1923) · QJM · doi:10.1093/qjmed/os-16.62.135 · Cited by 997
Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics
Lamarra, N., Whipp, B. J., Ward, S. A., & Wasserman, K. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.5.2003 · Cited by 569
THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1
Mitchell, J. H., Sproule, B. J., & Chapman, C. B. (1958) · Journal of Clinical Investigation · doi:10.1172/jci103636 · Cited by 516
The Elements of the Science of Nutrition.
(1911) · Archives of Internal Medicine · doi:10.1001/archinte.1911.00060040141010 · Cited by 477
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Research works printed but not linked: 7
- Noakes, 1998, Med Sci Sports Exerc, 30, 1381
- Robergs, 2001, JEPonline, 4, 1
- Cumming, 1972, Med Sci Sports Exerc, 4, 18
- Dwyer, 2004, JEPonline, 7, 1
- Myers, 1989, Med Sci Sports Exerc, 96, 1312
- Astorino, 2000, JEPonline, 3, 1
- Weir, 2004, JEPonline, 7, 55
Cited by
Items 201–300 of 358
Comparisons of the Metabolic Intensities at Heart Rate, Gas Exchange, and Ventilatory Thresholds
Succi, P. J., Dinyer, T. K., Byrd, M. T., & Bergstrom, H. C. (2020) · International journal of exercise science · doi:10.70252/ibrc8606 · Cited by 10
Lathouwers, E., Dons, E., Ampe, T., Panis, L. I., Verstraelen, M., & de Geus, B. (2021) · Journal of Transport & Health · doi:10.1016/j.jth.2021.101132 · Cited by 7
Possamai, L. T., Guglielmo, L. G. A., Salvador, A. F., Denadai, B. S., & Salvador, P. C. D. N. (2024) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2364425 · Cited by 7
“The VO 2 max was defined as the highest 15 seconds average VO 2 value reached during the test (Robergs et al., 2010).”
Rivadulla, A. R., Chen, X., Cazzola, D., Trewartha, G., & Preatoni, E. (2024) · Sports Biomechanics · doi:10.1080/14763141.2024.2372608 · Cited by 12
“Additionally, _ VO 2 data were smoothed using a 15-breath rolling average and the highest smoothed _ VO 2 during the test was identified and normalised to body mass ( _ VO 2 peak ) (Robergs et al., 2010).”
Brochhagen, J., & Hoppe, M. (2025) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2025.1583313 · Cited by 8
“For data processing, a moving average of ten breaths was applied, as reported before (45, 46).”
Fonseca, A. A., Figueiredo, P. H. S., Costa, H. S., Mota, L. T. C., de Deus, F. Â., Cardoso, R. F., da Fonseca, S. F., Janaudis‐Ferreira, T., Lacerda, A. C. R., & Lima, V. P. (2021) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2021.09.018 · Cited by 7
Predicting resting energy expenditure in people with chronic spinal cord injury
Ma, Y., de Groot, S., Hoevenaars, D., Achterberg, W. P., Adriaansen, J. J. E., Weijs, P. J. M., & Janssen, T. W. J. (2022) · Spinal Cord · doi:10.1038/s41393-022-00827-5 · Cited by 6
“A 30 s moving average filter was used to smooth the VO2 and VCO2 data before calculation [27, 28].”
MethodComplexity of Running and Its Relationship with Joint Kinematics during a Prolonged Run
Panday, S. B., Pathak, P., Moon, J., & Koo, D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19159656 · Cited by 9
“04 Hz was applied with custom Matlab Script to attenuate the variability in the data acquired using a breath-by-breath protocol [61].”
MethodRosoł, M., Petelczyc, M., Gąsior, J. S., & Młyńczak, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0291706 · Cited by 9
“Furthermore, the obtained data was visually evaluated in order to discard measurements during which there were visible artefacts in HR acquisition (e.g., sudden drop of over 30 bpm or lack of continuity of HR time-series during CPET probably due to electrode detachment); ultimately 369 recordings…”
MethodHeydenreich, J., Schütz, Y., Melzer, K., & Kayser, B. (2019) · Current Issues in Sport Science (CISS) · doi:10.15203/ciss_2019.003 · Cited by 7
Anthropometric Characteristics of Female and Male Athletes Bear A Different Effect on Fitness
Carter-Thuillier, B. I., Ramírez‐Campillo, R., Serra-Olivares, J., Gallardo-Fuentes, F., Cresp, M., Nahuelcura, R. O., Álvarez, C., Martínez‐Salazar, C., & Cañas-Jamett, R. (2019) · Asian Journal of Sports Medicine · doi:10.5812/asjsm.66164 · Cited by 8
Schaun, G. Z., Alberton, C. L., Gomes, M. L. B., Santos, L. P., Bamman, M. M., Mendes, G. F., HÄFELE, M. S., Andrade, L. S., Alves, L., de Ataides, V. A., et al. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002598 · Cited by 8
“2 values were time-averaged every 20 s and the average from the last two 20-s intervals in both GXT and VER were considered as phase-specific 2max (13, 27).”
MethodMaximal and Submaximal Cardiorespiratory Responses to a Novel Graded Karate Test
Hausen, M., Freire, R., Machado, A. B., Pereira, G. R., Millet, G. P., & Itaborahy, A. D. S. (2021) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2021.310 · Cited by 12
Kleinnibbelink, G., van Dijk, A. P. J., Fornasiero, A., Speretta, G. F. F., Johnson, C., Sculthorpe, N. F., George, K., Somauroo, J. D., Thijssen, D. H. J., & Oxborough, D. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01075.2020 · Cited by 9
“VO2max was defined as the highest 140 value of a 30-s average(31), and attainment was verified according to previous recommend 141 criteria.”
MethodComparison of Vo 2peak and Vo 2max at Different Sampling Intervals in Collegiate Wrestlers
Sell, K. M., Ghigiarelli, J. J., Prendergast, J. M., Ciani, G. J., Martin, J., & Gonzalez, A. M. (2021) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003887 · Cited by 6
“V̇O2maxdetermined throughanaverage sampling frequencybetween 5-s and 30-s (2,6,19); however, the differences between BbB values and V̇O2max from3-b or 7-b averaging have not beenwidely used or discussed in published research (11,18).”
BackgroundInfluentialEager to set a record in a vertical race? Test your VO 2max first!
Fornasiero, A., Savoldelli, A., Zignoli, A., Callovini, A., Decet, M., Bortolan, L., Schena, F. F., & Pellegrini, B. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2172801 · Cited by 7
“VO2max was defined as the highest values of a 20-s average (Robergs et al., 2010) whilst VT2 was defined by experienced exercise physiologists according to wellestablished methods (Wasserman et al., 1999).”
MethodSousa, F. A. D. B., Manchado-Gobatto, F. D. B., Rodrigues, N. D. A., & Gobatto, C. A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0266012 · Cited by 5
“_ VO2, VCO2, and VE were filtered using a rolling average of 30 seconds [41].”
MethodValidity of submaximal aerobic capacity and strength tests in firefighters
Hart, W., Taylor, D., & Bishop, D. C. (2024) · Occupational Medicine · doi:10.1093/occmed/kqae004 · Cited by 7
“Heart rate was recorded throughout (Polar H10, Polar, Finland), with HR peak calculated as the highest 30-second average value recorded during the test [6,22].”
MethodAktitiz, S., Koşar, Ş. N., & Turnagöl, H. H. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05434-1 · Cited by 5
“The highest value achieved over a 30-s sampling period was used as the ̇ V O 2 peak value (Robergs et al. 2010).”
MethodPhysical Capacities and Combat Performance Characteristics of Male and Female Olympic Boxers
Hausen, M., Taylor, L. K., Bachini, F., Freire, R., Pereira, G. R., & Itaborahy, A. D. S. (2024) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2024.2325683 · Cited by 13
“Cardiorespiratory data were processed using a smoothing of 15 data points (Robergs et al., 2010) alongside a fixed 20s time-average to avoid respiratory frequency bias for ventilatory thresholds (VT) determination.”
de Santana, J. L., Enzner, T., Blunderfield, B., Mendelson, A. A., & Villar, R. (2025) · Experimental Physiology · doi:10.1113/ep092337 · Cited by 5
Influence of Trail Running Footwear Foam on Running Economy and Perceptual Metrics
Muzeau, M. A., Flood, A., Tam, N., Abel, B., Saunders, P. U., Staiano, W., & Rattray, B. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.70059 · Cited by 7
“Data processing is reported in line with Nolte et al. (2023) recommendations and adhered to Robergs et al. (2010) guidance, implemented using custom Python code.”
Hanson, N., Reid, C., Cornwell, K. M., Lee, T. L., & Scheadler, C. M. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3656-3 · Cited by 5
Wang, Z., ATAKAN, M. M., Yan, X., Turnagöl, H. H., Duan, H., & Peng, L. (2021) · PLoS ONE · doi:10.1371/journal.pone.0246303 · Cited by 5
Succi, P. J., Dinyer, T. K., Voskuil, C. C., Abel, M. G., Clasey, J. L., & Bergstrom, H. C. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004547 · Cited by 6
Moderate intensity active recovery improves performance in a second wingate test in cyclists
Gervasi, M., Fernández-Peña, E., Patti, A., Benelli, P., Sisti, D., Padulo, J., & Boullosa, D. A. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e18168 · Cited by 7
“Heart rate (HR) was continuously recorded with the Polar RS-800 heart rate monitor (POLAR, Kempele, Finland) [23].”
MethodFreire, R., Hausen, M., Sanders, G. J., & Itaborahy, A. D. S. (2023) · Journal of Science in Sport and Exercise · doi:10.1007/s42978-023-00249-6 · Cited by 8
“Breath-by-breath data points were subjected to a smoothing process of 15 data points [22] and then averaged over 20-s intervals to avoid respiratory frequency bias for ventilatory thresholds (VTs) determination.”
O’Malley, B., Robergs, R. A., & Astorino, T. A. (2024) · Sports Medicine and Health Science · doi:10.1016/j.smhs.2024.02.002 · Cited by 5
Self-citationProfessional long distance runners achieve high efficiency at the cost of weak orbital stability
Panday, S. B., Pathak, P., & Ahn, J. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e34707 · Cited by 4
“Considering that we obtained the indirect calorimetry data through the breath-by-breath method, we filtered the raw data using a zero-lag 4th order low-pass Butterworth filter with the cut-off frequency of 0.04 Hz [49].”
MethodInfluentialThomson, A. C., Ramos, J. S., Fassett, R. G., Coombes, J. S., & Dalleck, L. C. (2015) · Research in Sports Medicine · doi:10.1080/15438627.2015.1076411 · Cited by 5
“Robergs, Dwyer, and Astorino (2010) reported that despite potential variability in the data caused by natural breathing irregularities, the accuracy of breath-by-breath analysis has been associated with minimal data loss and negligible trend distortion.”
BackgroundBaumgart, J. K., Skovereng, K., & Sandbakk, Ø. B. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00857 · Cited by 5
“(R2016a; Mathworks Inc., Natick, MA) The single highest 30-s average value was then identified as VO2peak as recommended by Robergs et al. (2010) and used in the further analyses.”
MethodFleckenstein, D., Ueberschär, O., Wüstenfeld, J. C., Rüdrich, P., & Wolfarth, B. (2021) · Sports · doi:10.3390/sports9040051 · Cited by 8
“According to current research, VO2max was determined as the highest value averaged over 30 s [21].”
MethodAlrashidi, A., Nightingale, T. E., Bhangu, G. S., Bissonnette-Blais, V., & Krassioukov, A. V. (2022) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2022.11.015 · Cited by 8
Arabatzi, F., Tziagkalou, E., Kannas, T., Giagkazoglou, P., Kofotolis, N. D., & Kellis, E. (2018) · Asian Journal of Sports Medicine · doi:10.5812/asjsm.60796 · Cited by 8
Hutchinson, M. J., Valentino, S. E., de Zepetnek, J. O. T., MacDonald, M. J., & Goosey-Tolfrey, V. L. (2019) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0062 · Cited by 5
“140 Data collection and processing 141 ventilation (V̇E) were computed as rolling 15-breath averages throughout the tests with the 143 greatest single value taken as the peak response (Robergs et al. 2010).”
MethodHanson, N., Carriveau, D. M., Morgan, H. E., Smith, A. R., Michael, T. J., & Miller, M. G. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001933 · Cited by 5
“The data were analyzed breath-bybreath and the 15-breath moving averages were used to determine the maximal value (21).”
MethodHemodynamic and metabolic responses to self-paced and ramp-graded exercise testing protocols
Beltz, N. M., Amorim, F. T., Gibson, A. L., Janot, J. M., Kravitz, L. R., Mermier, C. M., Cole, N. H., Moriarty, T. A., Nuñez, T. P., Trigg, S., et al. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0608 · Cited by 9
Disproportional ventilatory response to incremental exercise in individuals with cerebral palsy
Corell, L., Hjalmarsson, E., Fernandez‐Gonzalo, R., Kruse, A., Edman, S., Kizyte, A., Wang, R., Bos, A. M. M. E., Sörensson, P., Pontén, E., et al. (2026) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.70164 · Cited by 5
Muscle Synergy of Collegiate Rowers During 6 Min Maximal Rowing on Fixed and Slides Ergometer
Shaharudin, S., & Agrawal, S. K. (2015) · Journal of Medical and Bioengineering · doi:10.12720/jomb.4.4.263-269 · Cited by 6
Estimation of the metabolic rate in the occupational field: a regression model using accelerometers
Falcone, T., Ferraro, S. D., Molinaro, V., Zollo, L., & Lenzuni, P. (2023) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2023.103454 · Cited by 5
Absolute and relative intensities of solo, free-form dancing in adults: A pilot study
McCullough, A. K. (2024) · PLoS ONE · doi:10.1371/journal.pone.0313144 · Cited by 5
The prevalence of gas exchange data processing methods: a semi-automated scoping review
Hesse, A. S., White, M., & Lundstrom, C. J. (2025) · International Journal of Sports Medicine · doi:10.1055/a-2495-5364 · Cited by 5
A Metabolic Profile of Peripheral Heart Action Training
Mang, Z. A., Moriarty, T. A., Realzola, R. A., Millender, D. J., Wells, A. D., Houck, J. M., Bellissimo, G. F., Fennel, Z. J., Beam, J. R., Mermier, C. M., et al. (2021) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2020.1856315 · Cited by 5
“For the VO2max trial, the highest 11- breath averaged datapoint was recorded as VO2max (Robergs et al., 2010).”
MethodFacemask Use During High Intensity Interval Exercise in Temperate and Hot Environments
Wells, A. D., Fennel, Z. J., Ducharme, J. B., Masoud, A. A., Houck, J. M., Bellovary, B. N., Deyhle, M. R., Hsiao, Y., Amorim, F. T., & Mermier, C. M. (2021) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000002461 · Cited by 4
“, TrueOne 2400, Salt Lake City, UT) and data were analyzed using an 11-breath rolling average.(20) Primary criteria for a VO2max was categorized as an observed plateau that varied by less than 150mLO2/min.”
MethodMethodological considerations for the determination of VO2max in healthy men
Succi, P. J., Benitez, B., Kwak, M., & Bergstrom, H. C. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-05033-y · Cited by 4
spiro: An R package for analyzing data from cardiopulmonary exercise testing
Nolte, S. (2023) · The Journal of Open Source Software · doi:10.21105/joss.05089 · Cited by 4
Succi, P. J., Benitez, B., Kwak, M., & Bergstrom, H. C. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003127 · Cited by 4
Precisión de las ecuaciones para estimar la frecuencia cardíaca máxima en cicloergómetro
Marins, J. C. B., Delgado‐Fernández, M., & Peinado, P. J. B. (2013) · Archivos de medicina del deporte: revista de la Federación Española de Medicina del Deporte y de la Confederación Iberoamericana de Medicina del Deporte · Cited by 17
Cochrane, K. C., Housh, T. J., Hill, E. C., Smith, C. M., Jenkins, N. D. M., Cramer, J. T., Johnson, G., & Schmidt, R. J. (2015) · Sports · doi:10.3390/sports3040369 · Cited by 7
“The O2, CO2, and ventilatory parameters were expressed as 20 s averages [22] and the participants were fitted with a Polar Heart Watch system (Polar Electro Inc.”
MethodGordon, D. A., Swain, P., Keiller, D. R., Merzbach, V., Gernigon, M., & Chung, H. C. (2020) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.19.09912-2 · Cited by 6
Patrício, S. C., Sarnaglia, A. J. Q., Molinares, F. A. F., & de Azevedo, P. H. S. M. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069458 · Cited by 5
Competitive Demands and Performance-Determining Variables in Olympic Ski Mountaineering
Fornasiero, A., Savoldelli, A., Mattivi, M., Forrer, T., Todesco, B., Cuniberti, G. C., Callovini, A., Schena, F. F., Holmberg, H., Pellegrini, B., et al. (2025) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2024-0451 · Cited by 4
Similar Time Near VO2max Regardless of Work Rate Manipulation in Cycling Interval Training
Wommer, D., Turnes, T., de Souza, K. M., & Guglielmo, L. G. A. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1550-9977 · Cited by 4
“During the maximal ramp incremental test, V̇O2max was taken as the highest 15-second mean value achieved [12] and maximal heart rate (HRmax) as the highest 5-second mean value attained.”
MethodBaumgartner, N., Kranzinger, C., Kranzinger, S., Snyder, C., STÖGGL, T. L., & Resch, B. (2023) · Int. J. Comput. Sci. Sport · doi:10.2478/ijcss-2023-0005 · Cited by 3
Zdzieblik, D., Waldvogel, T., Zierke, A., Gollhofer, A., & König, D. (2024) · Nutrition and Metabolic Insights · doi:10.1177/11786388241299896 · Cited by 4
Jumping on the moon as a potential exercise countermeasure
Swain, P., Santos, F. C., Hughes, L., Gordon, D. A., & Caplan, N. (2025) · Experimental Physiology · doi:10.1113/ep092155 · Cited by 3
“(Robergs et al., 2010).”
Astorino, T. A., Bogdanis, G. C., & Costa, E. C. (2025) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph22070999 · Cited by 4
“In addition, ˙VO 2 was recorded breath by breath, which augments the ˙VO 2 response compared to longer time-averaging intervals [31].”
Self-citationSplinter, Z. T., & Wilson, P. B. (2019) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.18.09115-6 · Cited by 3
Falcone, T., Ferraro, S. D., Molinaro, V., Zollo, L., & Lenzuni, P. (2022) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot54413.2022.9831532 · Cited by 3
Zignoli, A., Fornasiero, A., Gilli, F., Pellegrini, B., & Schena, F. F. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104836 · Cited by 3
Oxygen uptake and heart rate responses to 4 weeks of RPE-guided handcycle training
Hutchinson, M. J., Paulson, T. A. W., Leicht, C. A., Bennett, H., Eston, R. G., & Goosey-Tolfrey, V. L. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05210-7 · Cited by 4
“V̇O2 , HR and PO were collected throughout tests, then subjected to 30 s rolling averages, with the greatest single value taken as the peak response (Robergs et al. 2010).”
MethodFeedback control of oxygen uptake during robotics-assisted end-effector-based stair climbing
Riedo, J., & Hunt, K. J. (2017) · Systems Science & Control Engineering · doi:10.1080/21642583.2017.1297261 · Cited by 4
Nutrition and Indirect Calorimetry
Ahmad, D., Joseph, K., & Halpin, C. (2016) · InTech eBooks · doi:10.5772/64385 · Cited by 2
“If the range is noted to be too low then many data points that are valid can be excluded from the analysis and thus providing distorted data values [8].”
InfluentialPanassollo, T. R. B., Rashid, U., Lord, S., Taylor, D., & Mawston, G. A. (2025) · Applied Sciences · doi:10.3390/app15052433 · Cited by 2
Dreismickenbecker, E., Stephan, H., WIESE, J., Anders, M., Kreuzer, M., Fleckenstein, J., Henkemeier, U., Faber, J., Hilberg, T., & Tomschi, F. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003781 · Cited by 2
“The maximum oxygen consumption ( ˙ VO 2max ) was recorded as the highest value during the measurement (48).”
Zang, W., Wu, J., Wu, J., Zhang, Z., Wang, S., & Zhang, Q. (2026) · Bioengineering · doi:10.3390/bioengineering13070774 · Cited by 2
“Conventional indirect calorimetry based on gas exchange has limited temporal resolution and is affected by physiological response delays, making it difficult to estimate metabolic changes within windows lasting only a few seconds [14].”
Forte, L. D. M., Manchado-Gobatto, F. D. B., Rodrigues, R. C. M., Gallani, M. C. B. J., & Gobatto, C. A. (2017) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2017.02.001 · Cited by 2
Schaun, G. Z., Alberton, C. L., Gomes, M. L. B., Mendes, G. F., Häfele, M. S., Andrade, L. S., Campelo, P., Ferreira, H. K., Oppelt, L. D. L., Galliano, L. M., et al. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2081403 · Cited by 3
“VO2 values were time-averaged every 20s, and the average from the last two 20-s intervals in both GXT and VER was considered as phase-specific VO2max (Astorino, 2009; Robergs et al., 2010).”
MethodDunston, E. R., & Taylor, K. (2023) · International journal of exercise science · doi:10.70252/fqav8949 · Cited by 7
Metabolic and Perceptual Responses to Constant Heart Rate Exercise at Vigorous Intensities in Women
Gustave, D., Mitchinson, C. J., Succi, P. J., Benitez, B., Kwak, M., Lanphere, K. R., Clasey, J. L., & Bergstrom, H. C. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003381 · Cited by 3
“This increase in the oxygen cost per W reflects a decrease in metabolic efficiency, which is consistent with fatiguing exercise at a constant power output above the VT (16,17,22,30).”
BackgroundMethodVigorous intensity heart rate-clamp exercise does not elicit recommended oxygen consumption rates
Mitchinson, C. J., Gustave, D., Succi, P. J., Benitez, B., Kwak, M., & Bergstrom, H. C. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05665-2 · Cited by 4
“The oxygen (O 2 ) and carbon dioxide (CO 2 ) parameters were expressed as 20-s averages (Robergs et al. 2010).”
McCullough, A. K. (2025) · Journal of Alzheimer s Disease · doi:10.1177/13872877251336482 · Cited by 5
VO2 Kinetics during Different Forms of Cycling Exercise on Land and in Water
Fenzl, M., Karner-Rezek, K., Schlegel, C., Gredig, J., & Villiger, B. (2015) · Sports and Exercise Medicine - Open Journal · doi:10.17140/semoj-1-110 · Cited by 2
Vilarinho, R., Mendes, A. R., Gomes, M., Ferreira, R. C., Costa, F., Machado, M., Neves, M., Caneiras, C. S. G., & Montes, A. M. (2021) · Healthcare · doi:10.3390/healthcare9030308 · Cited by 2
“To the best of our knowledge, this was the first study to observe the maximal effort attainment in an adapted step test by using the cluster of measures HR, blood lactate, and Borg rating [3,14,15].”
BackgroundMethodATPase Inhibitory Factor 1—A Novel Marker of Cellular Fitness and Exercise Capacity?
Domin, R., Pytka, M., Niziński, J., Żołyński, M., Zybek‐Kocik, A., Wrotkowska, E., Zieliński, J., Guzik, P., & Ruchała, M. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232315303 · Cited by 5
“For this investigation, we used averaged CPET values from the last 15 s of the rest and warm-up phases, and preceding VT1, VT2, and peak exercise [65].”
MethodKim, J., Park, J., Yang, J., Kim, Y., In-Hyung, K., Shim, H., Jang, C., Kim, M., Kim, M., & Lee, B. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20010299 · Cited by 2
“XR: muscles on the right, XL: muscles on the left 177 Here, the SI values ranged from the lowest (0%) to the highest (200%), with values 178 closer to 0% indicating a higher level of symmetry [37].”
BackgroundInfluentialTime Spent Near V˙O2max During Different Cycling Self-Paced Interval Training Protocols
Agnol, C. D., Turnes, T., & de Lucas, R. D. (2021) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2020-0314 · Cited by 6
Dubé, P.-A. (2014) · PolyPublie (École Polytechnique de Montréal) · Cited by 2
Feter, N., Häfele, C. A., Cassuriaga, J., Smith, E. C., Häfele, V., Rosseto, L., Coombes, J. S., Rombaldi, A. J., & da Silva, M. C. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2021.108086 · Cited by 1
Evaluating Airflow Sensor Methods: Precision in Indirect Calorimetry
Titheradge, P. J., & Robergs, R. A. (2024) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14674 · Cited by 1
“Using the 15-breath average method of ̇ V O 2 data collected from the ramp test [59] the ventilatory threshold (VT) of each subject was determined visually by the excess carbon dioxide method [60], using a custom-designed computer program (LabVIEW, National Instruments, Austin, TX, USA).”
BackgroundMethodSelf-citationSucci, P. J., Benitez, B., Kwak, M., Mitchinson, C. J., Butterfield, T. A., Samaan, M. A., Clasey, J. L., & Bergstrom, H. C. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05698-7 · Cited by 2
“The oxygen ( ̇ VO 2 ) and carbon dioxide ( ̇ V CO 2 ) parameters were expressed as 20-s averages (Robergs et al. 2010).”
A case report of the female world record holder from 1,500 m to the marathon in the 75+ age category
Hooren, B. V., Balamouti, Z., & Zanini, M. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00974.2024 · Cited by 2
A resting-state fMRI cross-sectional study of cardiorespiratory fitness decline after stroke
Qu, Q., Zhang, K., Wang, H., Zhu, J., Lin, Y., & Jia, J. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1465467 · Cited by 1
McCullough, A. K., Lawless, S., & Martins-Klein, B. (2025) · Journal of Alzheimer s Disease · doi:10.1177/13872877251315054 · Cited by 1
“All breath-by-breath ˙ V O 2 data were smoothed using a 15-breath moving average fi lter, 40 and total energy expenditure (kilocalories, kcal) for each participant was calculated as kcal × min − 1 = ˙ V O 2 L × min − 1 × 5.”
Lanzarini, L. D. V., Wommer, D., Ventura, T. P., dos Santos, J. D. S., Lana, I. D., Marafon, Â. M., Guglielmo, L. G. A., & Turnes, T. (2026) · German Journal of Exercise and Sport Research · doi:10.1007/s12662-025-01087-0 · Cited by 1
Fohrmann, D., Schaffarczyk, M., Menge, C., Willwacher, S., Sanchez-Alvarado, A., Gronwald, T., & Hollander, K. (2026) · Sports Medicine - Open · doi:10.1186/s40798-026-01005-0 · Cited by 4
“To confirm a steady rate of oxygen consumption, we fitted a linear regression over these 3-minute periods and verified that the slope was below the recommended threshold of 150 mL·min ⁻ ¹, indicating minimal drift in VO₂ and thus steady-state conditions, as previously reported [20, 31].”
The PhasED Framework: A Measurement Theory-Based Approach to Algorithm Development and Evaluation
Keadle, S. K., Strath, S. J., Giurgiu, M., Fuller, D., Martinez, J., Doherty, A., Ahmadi, M., Hyde, E. T., Troiano, R. P., & Matthews, C. E. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2025-0074 · Cited by 3
Physiological responses at the critical heart rate during treadmill running
Bergstrom, H. C. (2014) · Lincoln (University of Nebraska) · Cited by 2
McGarty, A. M., Penpraze, V., & Melville, C. A. (2015) · Pilot and Feasibility Studies · doi:10.1186/s40814-015-0014-2 · Cited by 2
“However, there is currently no universally accepted method for processing breath-by-breath _ VO2 data, which is impacting on the validity of data processing and interpretation [21].”
MethodThe Effectiveness of Standing on a Balance Board for Increasing Energy Expenditure
Nelson, M. C., Casanova, M. P., & Vella, C. A. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001595 · Cited by 2
“The last 20 min of data was used for analysis, and each metabolic variable was processed using a 15-breath-moving average (28).”
MethodRelationship between aerobic fitness, antioxidant capacity and the anti-aging hormone, Klotho
Nava, R. C., Zuhl, M., Bourbeau, K., Moriarty, T. A., Welch, A. M., & Mermier, C. M. (2020) · Gazzetta Medica Italiana Archivio per le Scienze Mediche · doi:10.23736/s0393-3660.18.03972-4 · Cited by 2
Application of V̇o 2 to the Critical Power Model to Derive the Critical V̇o 2
Succi, P. J., Dinyer, T. K., Byrd, M. T., Voskuil, C. C., & Bergstrom, H. C. (2021) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004134 · Cited by 1
“The oxygen (O2) and carbon dioxide (CO2) parameters were expressed as 20-s averages (35).”
MethodSucci, P. J., Benitez, B., Kwak, M., & Bergstrom, H. C. (2023) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk8030124 · Cited by 6
“VCO 2 ) parameters were expressed as 20 s averages [31].”
MethodVentura, T. P., Borszcz, F. K., Antunes, D., Caputo, F., & Turnes, T. (2023) · Journal of Human Kinetics · doi:10.5114/jhk/170101 · Cited by 1
“V ̇ O 2peak during the constant work rate trials was defined for each test as the highest average V ̇ O 2 over a 15-s period (Robergs et al., 2010).”
MethodPrior acute exercise restores postprandial fat oxidation in active cannabis users
Schubert, M. M., Terauds, S., Plant, M., Handler, G., Atkins, C., & Mendez, C. (2024) · Physiological Reports · doi:10.14814/phy2.15968
“VO 2 peak was confirmed with at least two of the following criteria: rate of perceived exertion (RPE) ≥ 17; heart rate ± 10 of age-predicted maximum; respiratory exchange ratio (RER) ≥ 1.10; and/or a plateau in VO 2 < 2 mL ⋅ kg −1 ⋅ min −1 (Robergs et al., 2010).”
InfluentialBellissimo, G. F., Bailly, A. R., Bourbeau, K., Mermier, C. M., Campitelli, A., Berkemeier, Q., Specht, J. W., Smith, J. M., Ducharme, J. B., Stork, M., et al. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1527171 · Cited by 3
Lopes, A. L. D. C., Sarro, K. J., Rodrigues, I. M., Bernardina, G. R. D., Sousa, F. A. D. B., Rodrigues, N. D. A., Massaroni, C., Schena, E., Silvestri, S., Cerveri, P., et al. (2025) · Sports Biomechanics · doi:10.1080/14763141.2025.2513474 · Cited by 2
“The V O 2 max was defined by the plateau of VO 2 (an increase in VO 2 150 mL/min, followed by its variant increasing 2 ml/kg/min) or, when this value was not achieved, by values of respiratory exchange ratio (RER) overcoming 1.1 (Robergs et al., 2010).”
InfluentialBaumgartner, N., Kranzinger, C., Kranzinger, S., Snyder, C., STÖGGL, T. L., & Resch, B. (2023) · Advances in intelligent systems and computing · doi:10.1007/978-3-031-31772-9_12 · Cited by 1
West, C. R. (2011) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 1
Muscle synergies in different physiological demands during rowing
Shaharudin, S. (2014) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/4v35-sm20 · Cited by 2
Metadata
- Authors
- Robergs, R. A., Dwyer, D., & Astorino, T.
- Affiliations
- University of New Mexico (US)
- University of Newcastle Australia (AU)
- California State University System (US)
- Corresponding author
- Robergs, Robert A.
- Venue
- Sports Medicine
- Published
- 2010-02
- Volume
- 40
- Issue
- 2
- Pages
- 95-111
- ISSN
- 0112-1642 (ISSN-L)
- OpenAlex
- W2011094458
- Cited by
- 356
- References
- 40
- Citations by year
- 2026: 24 · 2025: 28 · 2024: 21 · 2023: 28 · 2022: 35 · 2021: 27 · 2020: 26 · 2019: 34 · 2018: 22 · 2017: 26 · 2016: 13 · 2015: 28 · 2014: 14 · 2013: 13 · 2012: 6
- FWCI
- 25.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- NOVA (University of Newcastle Australia) (submittedVersion)
- Faculty of Health; Institute of Health and Biomedical Innovation
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- indirect calorimetry, expired gas analysis, oxygen consumption, time averaging, digital filtering, incremental exercise, steady-state exercise, ventilation, respiratory exchange ratio, data variability, rating of perceived exertion
- MeSH terms
- Electronic Data Processing, Calorimetry, Indirect, Humans, Oxygen Consumption, Exercise, Exhalation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.