Recommendations for Improved Data Processing from Expired Gas Analysis Indirect Calorimetry
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
There is currently no universally recommended and accepted method of data processing within the science of indirect calorimetry for either mixing chamber or breath-by-breath systems of expired gas analysis. Exercise physiologists were first surveyed to determine methods used to process oxygen consumption ((.)VO2) data, and current attitudes to data processing within the science of indirect calorimetry. Breath-by-breath datasets obtained from indirect calorimetry during incremental exercise were then used to demonstrate the consequences of commonly used time, breath and digital filter post-acquisition data processing strategies. Assessment of the variability in breath-by-breath data was determined using multiple regression based on the independent variables ventilation (VE), and the expired gas fractions for oxygen and carbon dioxide, FEO2 and FECO2, respectively. Based on the results of explanation of variance of the breath-by-breath (.)VO2 data, methods of processing to remove variability were proposed for time-averaged, breath-averaged and digital filter applications. Among exercise physiologists, the strategy used to remove the variability in (.)VO2 measurements varied widely, and consisted of time averages (30 sec [38%], 60 sec [18%], 20 sec [11%], 15 sec [8%]), a moving average of five to 11 breaths (10%), and the middle five of seven breaths (7%). Most respondents indicated that they used multiple criteria to establish maximum ((.)VO2 ((.)VO2max) including: the attainme…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since Costill et al . [ 12 ] reported the improvement of physical performance after intake of caffeine, many studies have reported the same and claimed that ergogenic effect of caffeine was seen in people who had at least more than 2.5 mg/kg -1 . dose of caffeine intake [ 13 , 14 ].”
From Effect of energy drink dose on exercise capacity, heart rate recovery and heart rate variability after high-intensity exercise (2014) · cites this paper as [14]
Citations
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Limiting factors for maximum oxygen uptake and determinants of endurance performance
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00012 · Cited by 2,410
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Maximal Oxygen Intake as an Objective Measure of Cardio-Respiratory Performance
Taylor, H. L., Buskirk, E., & Henschel, A. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.1.73 · Cited by 1,342
Muscular Exercise, Lactic Acid, and the Supply and Utilization of Oxygen
Hill, A. V., & Lupton, H. (1923) · QJM · doi:10.1093/qjmed/os-16.62.135 · Cited by 997
Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics
Lamarra, N., Whipp, B. J., Ward, S. A., & Wasserman, K. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.5.2003 · Cited by 569
THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1
Mitchell, J. H., Sproule, B. J., & Chapman, C. B. (1958) · Journal of Clinical Investigation · doi:10.1172/jci103636 · Cited by 516
The Elements of the Science of Nutrition.
(1911) · Archives of Internal Medicine · doi:10.1001/archinte.1911.00060040141010 · Cited by 477
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
Breath-by-breath measurement of true alveolar gas exchange
Beaver, W. L., Lamarra, N., & Wasserman, K. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.6.1662 · Cited by 435
Mitchell, J. H., & Blomqvist, G. (1971) · New England Journal of Medicine · doi:10.1056/nejm197105062841809 · Cited by 339
Implications of exercise testing for prediction of athletic performance: a contemporary perspective
NOAKES, T. D. (1988) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198808000-00001 · Cited by 338
On-line computer analysis and breath-by-breath graphical display of exercise function tests.
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.1.128 · Cited by 318
Maximal oxygen uptake: ???classical??? versus???contemporary??? viewpoints
BASSETT, D. R., & HOWLEY, E. T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199705000-00002 · Cited by 240
Comparison of continuous and discontinuous treadmill and bicycle tests for max &OV0312;O2
McArdle, W. D., Katch, F. I., & Pechar, G. S. (1973) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197323000-00012 · Cited by 226
Automated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Effect of sampling on variability and plateau in oxygen uptake
Myers, J., Walsh, D., Sullivan, M., & Froelicher, V. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.1.404 · Cited by 193
Photoluminescence investigation of InGaAs-InP quantum wells
Moroni, D., André, J. P., Menu, E. P., Gentric, P., & Patillon, J. N. (1987) · Journal of Applied Physics · doi:10.1063/1.339541 · Cited by 188
Maximal oxygen uptake: "classical" versus "contemporary" viewpoints: a rebuttal
NOAKES, T. D. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199809000-00007 · Cited by 178
Challenging beliefs: ex Africa semper aliquid novi
NOAKES, T. D. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199705000-00001 · Cited by 168
Applicability of ??VO2max criteria: discontinuous versus continuous protocols
DUNCAN, G. E., HOWLEY, E. T., & JOHNSON, B. N. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199702000-00017 · Cited by 153
Maximum oxygen intake and maximum heart rate during strenuous work
Wyndham, C. H., Strydom, N. B., Maritz, J. S., Morrison, J. F., Peter, J., & Potgieter, Z. U. (1959) · Journal of Applied Physiology · doi:10.1152/jappl.1959.14.6.927 · Cited by 130
A comparison of three maximal treadmill exercise protocols.
Froelicher, V. F., Brammell, H. L., Davis, G., Noguera, I., Stewart, A., & Lancaster, M. C. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.6.720 · Cited by 122
Low frequency of the "plateau phenomenon" during maximal exercise in elite British athletes
Doherty, M., Nobbs, L., & Noakes, T. D. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0845-z · Cited by 122 · cited 1×
“[33,34,36,37]”
Incidence Of The Oxygen Plateau at VO2max During Exercise Testing To Volitional Fatigue
Astorino, T. A., Robergs, R. A., Ghiasvand, F., Marks, D. W., & Burns, S. P. (2000) · QUT ePrints (Queensland University of Technology) · Cited by 106
Self-citationCan Maximal Cardiopulmonary Capacity be Recognized by a Plateau in Oxygen Uptake?
MYERS, J. N., Walsh, D., Buchanan, N., & Froelicher, V. F. (1989) · CHEST Journal · doi:10.1378/chest.96.6.1312 · Cited by 91
Maximal oxygen uptake "classical" versus "contemporary" viewpoints
BERGH, U., EKBLOM, B., & ÅSTRAND, P.-O. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00013 · Cited by 67
Nonlinear interactions of particles in chains
Jones, T. B., & Saha, B. (1990) · Journal of Applied Physics · doi:10.1063/1.346836 · Cited by 64
Breath-to-breath “noise” in the ventilatory and gas exchange responses of children to exercise
Potter, C. R., Childs, D. J., Houghton, W., & Armstrong, N. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050567 · Cited by 50
Criteria for maximum oxygen uptake in men over 40 in a population survey.
Cumming, G. R., & Borysyk, L. M. (1972) · PubMed · Cited by 46
Gas Exchange Measurements with High Temporal Resolution: The Breath-by-Breath Approach
Röecker, K., Prettin, S., & Sorichter, S. (2005) · International journal of sports medicine. Supplement/International journal of sports medicine. Sup. · doi:10.1055/s-2004-830506 · Cited by 44
V˙O2max and the Plateau-Needed or Not?
HOWLEY, E. T. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802dc897 · Cited by 43
Robergs, R. A. (2001) · QUT ePrints (Queensland University of Technology) · Cited by 39
Self-citationComputer-based system for analysis of respiratory responses to exercise
Pearce, D. H., Milhorn, H. T., Holloman, G., & Reynolds, W. J. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.6.968 · Cited by 35
Whyte, G. P., SHARMA, S., George, K., & McKenna, W. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199909000-00002 · Cited by 12
Freedson, P. S., KLINE, G. M., Porcari, J. P., Hintermeister, R. A., McCarron, R., Ross, J. D. M., Hard, A., Gurry, H., & Rippe, J. (1986) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198604001-00176 · Cited by 9
HEART RATE/OXYGEN CONSUMPTION RELATIONSHIP DURING CYCLING
Clifford, P. S., Coast, J. R., Swain, D. P., Milliken, H. C., & Stray‐Gundersen, J. (1986) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198604001-00179 · Cited by 3
VO2 PLATEAU DETECTION IN CYCLE ERGOMETRY
Weir, J. P., Koerner, S., Mack, B., Mašek, J., & Vanderhoff, D. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105001-00260 · Cited by 3
(1973) · PubMed
Research works printed but not linked: 7
- Noakes, 1998, Med Sci Sports Exerc, 30, 1381
- Robergs, 2001, JEPonline, 4, 1
- Cumming, 1972, Med Sci Sports Exerc, 4, 18
- Dwyer, 2004, JEPonline, 7, 1
- Myers, 1989, Med Sci Sports Exerc, 96, 1312
- Astorino, 2000, JEPonline, 3, 1
- Weir, 2004, JEPonline, 7, 55
Cited by
Vella, C. A., Taylor, K., & Drummer, D. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1359679 · Cited by 188
Effect of aerobic exercise on cognition in younger adults: A randomized clinical trial
Stern, Y., MacKay-Brandt, A., Lee, S., McKinley, P., McIntyre, K., Razlighi, Q., Agarunov, E., Bartels, M., & Sloan, R. P. (2019) · Neurology · doi:10.1212/wnl.0000000000007003 · Cited by 178
Effects of cardiovascular exercise early after stroke: systematic review and meta-analysis
Stoller, O., de Bruin, E. D., Knols, R. H., & Hunt, K. J. (2012) · BMC Neurology · doi:10.1186/1471-2377-12-45 · Cited by 178
“there are no standardised evaluation methods [54].”
Kerling, A., Tegtbur, U., Guetzlaff, E., Kück, M., Borchert, L., Ateş, Z., von Bohlen, A., Frieling, H., Hüper, K., Hartung, D., et al. (2015) · Journal of Affective Disorders · doi:10.1016/j.jad.2015.01.006 · Cited by 129
“Maximum oxygen uptake (VO2max) is an important criterion for exercise capacity and describes the maximum O2 the body can utilize per minute under maximum load conditions and is above all dependent on oxygen exchange, transport and utilization systems (Robergs et al., 2010).”
BackgroundThe Maximal Oxygen Uptake Verification Phase: a Light at the End of the Tunnel?
Schaun, G. Z. (2017) · Sports Medicine - Open · doi:10.1186/s40798-017-0112-1 · Cited by 119
“[30] suggested that “time-averaged sampling should be no longer than 30 s” while “breath-averaged sampling should be” performed by “15-breath running averages”.”
BackgroundMethodInfluential
Metadata
- Authors
- Robergs, R. A., Dwyer, D., & Astorino, T.
- Affiliations
- University of New Mexico (US)
- University of Newcastle Australia (AU)
- California State University System (US)
- Corresponding author
- Robergs, Robert A.
- Venue
- Sports Medicine
- Published
- 2010-02
- Volume
- 40
- Issue
- 2
- Pages
- 95-111
- ISSN
- 0112-1642 (ISSN-L)
- OpenAlex
- W2011094458
- Cited by
- 356
- References
- 40
- Citations by year
- 2026: 24 · 2025: 28 · 2024: 21 · 2023: 28 · 2022: 35 · 2021: 27 · 2020: 26 · 2019: 34 · 2018: 22 · 2017: 26 · 2016: 13 · 2015: 28 · 2014: 14 · 2013: 13 · 2012: 6
- FWCI
- 25.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- NOVA (University of Newcastle Australia) (submittedVersion)
- Faculty of Health; Institute of Health and Biomedical Innovation
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- indirect calorimetry, expired gas analysis, oxygen consumption, time averaging, digital filtering, incremental exercise, steady-state exercise, ventilation, respiratory exchange ratio, data variability, rating of perceived exertion
- MeSH terms
- Electronic Data Processing, Calorimetry, Indirect, Humans, Oxygen Consumption, Exercise, Exhalation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.