Surface Chemistry Influences Implant Biocompatibility
Open accessThe DOI matches its Crossref record; 134 of the 135 references it cites were found in a registry or an index.
Abstract
Implantable medical devices are increasingly important in the practice of modern medicine. Unfortunately, almost all medical devices suffer to a different extent from adverse reactions, including inflammation, fibrosis, thrombosis and infection. To improve the safety and function of many types of medical implants, a major need exists for development of materials that evoked desired tissue responses. Because implant-associated protein adsorption and conformational changes thereafter have been shown to promote immune reactions, rigorous research efforts have been emphasized on the engineering of surface property (physical and chemical characteristics) to reduce protein adsorption and cell interactions and subsequently improve implant biocompatibility. This brief review is aimed to summarize the past efforts and our recent knowledge about the influence of surface functionality on protein:cell:biomaterial interactions. It is our belief that detailed understandings of bioactivity of surface functionality provide an easy, economic, and specific approach for the future rational design of implantable medical devices with desired tissue reactivity and, hopefully, wound healing capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, blood serum proteins could be absorbed via hydrophobic interaction, resulting in alteration to protein conformation.[ 160 ]”
From Unraveling and Harnessing the Immune Response at the Cell–Biomaterial Interface for Tissue Engineering Purposes (2024) · cites this paper as [160]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Arima, Y., & Iwata, H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.013 · Cited by 1,593
Plasma-surface modification of biomaterials
Chu, P. (2002) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(02)00004-9 · Cited by 1,578
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Interpretation of Protein Adsorption: Surface-Induced Conformational Changes
Roach, P., Farrar, D., & Perry, C. C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042898o · Cited by 1,479
Yin Win, K., & Feng, S.-S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.050 · Cited by 1,452
Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<299::aid-jbm2>3.0.co;2-8 · Cited by 995
Craddock, P. R., Fehr, J., Dalmasso, A. P., Brighan, K. L., & Jacob, H. S. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108710 · Cited by 991
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Research works printed but not linked: 10
- [13]Tang L, Eaton JW. Molecular determinants of acute inflammatory responses to biomaterials. Chapter 20. In: Zilla PP, Greisler HP, editors. Tissue engineering of prosthetic vascular grafts. RG Landes Company; Austin, Texas: 1999. pp. 207–218. [Google Scholar]
- [44]Schaaf P, Dejardin P. Structural changes within an adsorbed fibrinogen layer during the adsorption process: A study by scanning angle relectometry. Colloids Surf. 1988;31:89–100. [Google Scholar]
- [64]Sheu MS, Hudson DM, Loh IH. Biomaterial surface modification using plasma gas discharge processes. In: Wise DL, Trantolo DJ, Altobelli DE, Yaszemski MJ, Gresser JD, Schwartz ER, editors. Encyclopedic handbook of biomaterials and bioengineering, Part A: Materials. Marcel Dekker, Inc; New York: 1995. pp. 865–894. [Google Scholar]
- [69]Tang L, Lui L, Elwing H. Complement activation and inflammation triggered by model biomaterial surfaces. J Biomed Mater Res. 1998;41:330–340. doi: 10.1002/(sici)1097-4636(199808)41:2<333::aid-jbm19>3.0.co;2-l. [DOI] [PubMed] [Google Scholar] · DOI · Paper page
- [76]Savage CR, Lin JW, Timmons RB. Molecular control of surface film compositions via pulsed RF plasma polymerization of perfluoropropylene oxide. Chem Mater. 1991;3:575. [Google Scholar]
- [78]Rinsch CL, Eberhart RC, Savage CR, Timmons RB. Film chemistry control during the plasma polymerization of allylamine. Polym Preprints (ACS) 1995;36:95–97. [Google Scholar]
- [90]Lui L, Elwing H. Complement activation on thiol-modified gold surfaces. J Biomed Mater Res. 1996;30(4):535–541. doi: 10.1002/(SICI)1097-4636(199604)30:4<535::AID-JBM12>3.0.CO;2-G. [DOI] [PubMed] [Google Scholar] · DOI · Paper page
- [100]Lee JH, Khang G, Lee JW, Lee HB. Platelet adhesion onto chargeable functional group gradient surfaces. J Biomed Mater Res. 1998;40:180–186. doi: 10.1002/(sici)1097-4636(199805)40:2<180::aid-jbm2>3.0.co;2-h. [DOI] [PubMed] [Google Scholar] · doi:10.1002/(sici)1097-4636(199805)40:2<180::aid-jbm2>3.0.co;2-h
- [101]Lin JC, Chuang WH. Synthesis, surface characterization, and platelet reactivity evaluation for the self-assembled monolayer of alkanethiol with sulfonic acid functionality. J Biomed Mater Res. 2000;51(3):413–423. doi: 10.1002/1097-4636(20000905)51:3<413::aid-jbm16>3.0.co;2-l. [DOI] [PubMed] [Google Scholar] · doi:10.1002/1097-4636(20000905)51:3<413::aid-jbm16>3.0.co;2-l
- [108]Tang L, Wu Y, Timmons RB. Fibrinogen adsorption and host tissue responses to plasma functionalized surfaces. J Biomed Mater Res. 1998;42(1):156–163. doi: 10.1002/(sici)1097-4636(199810)42:1<156::aid-jbm19>3.0.co;2-j. [DOI] [PubMed] [Google Scholar] · DOI · Paper page
Cited by
Strategies in the design of nanoparticles for therapeutic applications
Petros, R. A., & DeSimone, J. M. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd2591 · Cited by 3,651
“The bulk composition of the engineered nanoparticle must be carefully chosen based on its biocompatibilit”
BackgroundUnderstanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Multiple Functionalities of Polyelectrolyte Multilayer Films: New Biomedical Applications
Boudou, T., Crouzier, T., Ren, K., Blin, G., & Picart, C. (2010) · Advanced Materials · doi:10.1002/adma.200901327 · Cited by 736
Knetsch, M. L. W., & Koole, L. H. (2011) · Polymers · doi:10.3390/polym3010340 · Cited by 715
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
“Moreover, the composition and state of these adsorbed proteins is considered to play a major role in the subsequent host coagulation and immune reactions [205,367].”
Background
Metadata
- Authors
- Tang, L., Thevenot, P., & Hu, W.
- Affiliations
- The University of Texas at Arlington (US)
- Venue
- Current Topics in Medicinal Chemistry
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2008-03-01
- Volume
- 8
- Issue
- 4
- Pages
- 270-280
- ISSN
- 1568-0266 (ISSN-L)
- PMC
- PMC3230929
- OpenAlex
- W2128392700
- Cited by
- 800
- References
- 135
- Citations by year
- 2026: 20 · 2025: 32 · 2024: 48 · 2023: 60 · 2022: 50 · 2021: 60 · 2020: 75 · 2019: 63 · 2018: 56 · 2017: 78 · 2016: 65 · 2015: 39 · 2014: 32 · 2013: 28 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Current Topics in Medicinal Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM074021)
- National Institute of Biomedical Imaging and Bioengineering (R01EB007271)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Keywords
- implant biocompatibility, surface chemistry, biomedical implants, protein adsorption, protein conformational change, cell-material interactions, surface functionalization, inflammation, thrombosis, infection, fibrosis, wound healing, biomaterial design
- MeSH terms
- Biocompatible Materials, Foreign-Body Reaction, Humans, Surface Properties, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.