The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
A Review of Fetal ECG Signal Processing Issues and Promising Directions
Open accessAbstract
The field of electrocardiography has been in existence for over a century, yet despite significant advances in adult clinical electrocardiography, signal processing techniques and fast digital processors, the analysis of fetal ECGs is still in its infancy. This is, partly due to a lack of availability of gold standard databases, partly due to the relatively low signal-to-noise ratio of the fetal ECG compared to the maternal ECG (caused by the various media between the fetal heart and the measuring electrodes, and the fact that the fetal heart is simply smaller), and in part, due to the less complete clinical knowledge concerning fetal cardiac function and development. In this paper we review a range of promising recording and signal processing techniques for fetal ECG analysis that have been developed over the last forty years, and discuss both their shortcomings and advantages. Before doing so, however, we review fetal cardiac development, and the etiology of the fetal ECG. A selection of relevant models for the fetal/maternal ECG mixture is also discussed. In light of current understanding of the fetal ECG, we then attempt to justify recommendations for promising future directions in signal processing, and database creation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
A dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224
An Accurate, Clinically Practical System For Spatial Vectorcardiography
FRANK, E. (1956) · Circulation · doi:10.1161/01.cir.13.5.737 · Cited by 1,094
Medical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
(2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181aef106 · Cited by 895
Exercise standards. A statement for health professionals from the American Heart Association.
Fletcher, G. F., Froelicher, V. F., Hartley, L. H., Haskell, W. L., & Pollock, M. L. (1990) · Circulation · doi:10.1161/01.cir.82.6.2286 · Cited by 723
Endocrine Regulation of Human Fetal Growth: The Role of the Mother, Placenta, and Fetus
Murphy, V. E., Smith, R., Giles, W. B., & Clifton, V. L. (2006) · Endocrine Reviews · doi:10.1210/er.2005-0011 · Cited by 671
Exercise Standards: A Statement for Healthcare Professionals From the American Heart Association
Fletcher, G. F., Balady, G., Froelicher, V. F., Hartley, L. H., Haskell, W. L., & Pollock, M. L. (1995) · Circulation · doi:10.1161/01.cir.91.2.580 · Cited by 566
Fetal electrocardiogram extraction by blind source subspace separation
de Lathauwer, L., de Moor, B., & Vandewalle, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841326 · Cited by 502
A Nonlinear Bayesian Filtering Framework for ECG Denoising
Sameni, R., Shamsollahi, M. B., Jutten, C., & Clifford, G. D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897817 · Cited by 502
The Limit of Viability -- Neonatal Outcome of Infants Born at 22 to 25 Weeks' Gestation
Allen, M. C., Donohue, P. K., & Dusman, A. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199311253292201 · Cited by 447
Li, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Multidimensional independent component analysis
Cardoso, J.-F. (2002) · Proceedings of the 1998 IEEE International Conference on Acoustics, Speech and Signal Processing, ICASSP '98 (Cat. No.98CH36181) · doi:10.1109/icassp.1998.681443 · Cited by 403
Amer-Wåhlin, I., Hellsten, C., Norén, H., Hagberg, H., Herbst, A., Kjellmer, I., Lilja, H., Lindoff, C., Månsson, M., Mårtensson, L., et al. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05703-8 · Cited by 402
Miniño, A., Heron, M. P., Murphy, S. L., & Kochanek, K. D. (2007) · PubMed · Cited by 390
Normal amniotic fluid volume changes throughout pregnancy
Brace, R. A., & Wolf, E. J. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90527-9 · Cited by 356
On Bioelectric Potentials in an Inhomogeneous Volume Conductor
Geselowitz, D. B. (1967) · Biophysical Journal · doi:10.1016/s0006-3495(67)86571-8 · Cited by 332
Uterine electromyography: A critical review
Devedeux, D., Marque, C., Mansour, S., Germain, G., & Duchêne, J. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(93)90456-s · Cited by 329
Fetal ECG extraction from single-channel maternal ECG using singular value decomposition
Kanjilal, P. P., Palit, S., & Saha, G. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553712 · Cited by 314
Noninvasive fetal electrocardiogram extraction: blind separation versus adaptive noise cancellation
Zarzoso, V., & Nandi, A. K. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.900244 · Cited by 308
Signorini, M. G., Magenes, G., Cerutti, S., & Arduini, D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808824 · Cited by 294
Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: A meta-analysis
Vintzileos, A. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00320-d · Cited by 271
The forward and inverse problems of electrocardiography
Gulrajani, R. M. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.715491 · Cited by 236
On the theory of the electrocardiogram
Geselowitz, D. B. (1989) · Proceedings of the IEEE · doi:10.1109/5.29327 · Cited by 224
Naming of the Waves in the ECG, With a Brief Account of Their Genesis
Hurst, J. W. (1998) · Circulation · doi:10.1161/01.cir.98.18.1937 · Cited by 220
Multichannel Electrocardiogram Decomposition Using Periodic Component Analysis
Sameni, R., Jutten, C., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919714 · Cited by 207
Extraction of Specific Signals with Temporal Structure
Barros, A. K., & Cichocki, A. (2001) · Neural Computation · doi:10.1162/089976601750399272 · Cited by 205
A robust fetal ECG detection method for abdominal recordings
Martens, S. M. M., Rabotti, C., Mischi, M., & Sluijter, R. J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/004 · Cited by 193
A new method for the extraction of fetal ECG from the composite abdominal signal
Khamene, A., & Negahdaripour, S. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.828150 · Cited by 192
Monitoring the fetal heart non-invasively: a review of methods
Peters, M., Crowe, J., Piéri, J.-F., Quartero, H., Hayes-Gill, B., James, D., Stinstra, J., & Shakespeare, S. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.057 · Cited by 190
Multichannel ECG and Noise Modeling: Application to Maternal and Fetal ECG Signals
Sameni, R., Clifford, G. D., Jutten, C., & Shamsollahi, M. B. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2007/43407 · Cited by 171
Ueber die Form des menschlichen Electrocardiogramms
Einthoven, W. (1895) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf01662582 · Cited by 164
Fetal Pulse Oximetry and Cesarean Delivery
Bloom, S. L., Spong, C. Y., Thom, E., Varner, M. W., Rouse, D. J., Weininger, S., Ramin, S. M., Caritis, S. N., Peaceman, A., Sorokin, Y., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061170 · Cited by 160
Fetal heart rate variability and complexity in the course of pregnancy
Leeuwen, P. V., Lange, S., Bettermann, H., Grönemeyer, D. H. W., & Hatzmann, W. (1999) · Early Human Development · doi:10.1016/s0378-3782(98)00102-9 · Cited by 155
Rhythm abnormalities of the fetus
Hornberger, L. K., & Sahn, D. J. (2007) · Heart · doi:10.1136/hrt.2005.069369 · Cited by 149
Fetal ECG extraction with nonlinear state-space projections
Richter, M., Schreiber, T., & Kaplan, D. T. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.650369 · Cited by 135
Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor
Zuckerwar, A. J., Pretlow, R. A., Stoughton, J. W., & Baker, D. A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.245618 · Cited by 100
Nonlinear noise reduction for electrocardiograms
Schreiber, T., & Kaplan, D. T. (1996) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166148 · Cited by 95
Li, Q., Mark, R. G., & Clifford, G. D. (2009) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-8-13 · Cited by 94
Extraction of Fetal Cardiac Signals from an Array of Maternal Abdominal Recordings
Sameni, R. (2008) · HAL · doi:10.13140/rg.2.2.14830.41285 · Cited by 88
Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring
Westgate, J., Harris, M., Curnow, J. S. H., & Greene, K. R. (1992) · The Lancet · doi:10.1016/0140-6736(92)90465-f · Cited by 86
Measurement of fetal liver, brain and placental volumes with echo–planar magnetic resonance imaging
Baker, P. N., Johnson, I. R., Gowland, P. A., Hykin, J., Adams, V., Mansfield, P., & Worthington, B. S. (1995) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1995.tb09023.x · Cited by 84
Assessment of fetal neurodevelopment via fetal magnetocardiography
Wakai, R. T. (2004) · Experimental Neurology · doi:10.1016/j.expneurol.2004.04.019 · Cited by 81
THE FETAL ELECTROCARDIOGRAM. IV. UNUSUAL VARIATIONS IN THE QRS COMPLEX DURING LABOR.
Lee, S. T., & Hon, E. H. (1965) · PubMed · Cited by 79
Two Methods for Optimal MECG Elimination and FECG Detection from Skin Electrode Signals
Vanderschoot, J., Callaerts, D., Sansen, W., Vandewalle, J. P. L., Vantrappen, G. R., & Janssens, J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325949 · Cited by 77
Lunshof, S., Boer, K., Wolf, H., van Hoffen, G., Bayram, N., & Mirmiran, M. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)80008-2 · Cited by 76
A Deflation Procedure for Subspace Decomposition
Sameni, R., Jutten, C., & Shamsollahi, M. B. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2037353 · Cited by 75
Amniotic Fluid Volume in Normal Singleton Pregnancies
Magann, E. F. (1997) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(97)00351-7 · Cited by 66
Model-based Bayesian filtering of cardiac contaminants from biomedical recordings
Sameni, R., Shamsollahi, M. B., & Jutten, C. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/5/006 · Cited by 61
The effect of changes in the conductive medium on the fetal ECG throughout gestation
Oostendorp, T. F., van Oosterom, A., & Jongsma, H. W. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/4b/002 · Cited by 60
Westerhuis, M. E. M. H., Moons, K. G. M., van Beek, E., Bijvoet, S. M., Drogtrop, A. P., van Geijn, H. P., Lith, J. M. M. V., Mol, B. W., Nijhuis, J. G., Oei, S. G., et al. (2007) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-7-13 · Cited by 60
Human ECG: nonlinear deterministic versusstochastic aspects
Kantz, H., & Schreiber, T. (1998) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:19982327 · Cited by 59
Fetal cardiac anomalies and genetic syndromes
Pajkrt, E., Weisz, B., Firth, H. V., & Chitty, L. S. (2004) · Prenatal Diagnosis · doi:10.1002/pd.1067 · Cited by 55
Clifford, G. D., & McSharry, P. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.544525 · Cited by 49
Signal separation by nonlinear projections: The fetal electrocardiogram
Schreiber, T., & Kaplan, D. T. (1996) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.53.r4326 · Cited by 49
Leeuwen, P. V., Lange, S., Klein, A., Geue, D., & Grönemeyer, D. H. W. (2004) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-4-6 · Cited by 47
The reliability of the fetal magnetocardiogram
Stinstra, J. G. (2001) · University of Twente Research Information · doi:10.3990/1.9789036516587 · Cited by 43
The use of the singular value decomposition in electrocardiography
Damen, A. A. H., & van der Kam, J. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442409 · Cited by 40
On detecting the presence of fetal R-wave using the moving averaged magnitude difference algorithm
Park, Y. C., Lee, K. Y., Youn, D. H., Kim, N. H., Kim, W. K., & Park, S. H. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.148396 · Cited by 40
Fetal position and size data for dose estimation.
Osei, E. K., & Faulkner, K. (1999) · British Journal of Radiology · doi:10.1259/bjr.72.856.10474497 · Cited by 39
Amer‐Wåhlin, I., Källén, K., Herbst, A., Rydhstroem, H., Sundström, A.-K., & Maršśl, K. (2005) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050500233191 · Cited by 38
Spatial filtering of the fetal electrocardiogram
van Oosterom, A. (1986) · Journal of Perinatal Medicine · doi:10.1515/jpme.1986.14.6.411 · Cited by 38
Eigenvector based spatial filtering of fetal biomagnetic signals
Chen, M., Wakai, R. T., & Veen, B. D. V. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.068 · Cited by 35
Fetal magnetocardiography: clinical relevance and feasibility
ter Brake, H. J. M., Rijpma, A. P., Stinstra, J. G., Borgmann, J., Holland, H. J., Krooshoop, H. J. G., Peters, M. J., Flokstra, J., Quartero, H. W. P., & Rogalla, H. (2002) · Physica C Superconductivity · doi:10.1016/s0921-4534(01)01132-7 · Cited by 31
Shao, M., Barner, K. E., & Goodman, M. H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821011 · Cited by 31
A successive cancellation algorithm for fetal heart-rate estimation using an intrauterine ECG signal
Lai, K.-C., & Shynk, J. J. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.802010 · Cited by 29
Sameni, R., Vrins, F. D., Parmentier, F., Hérail, C., Vigneron, V., Verleysen, M., Jutten, C., & Shamsollahi, M. B. (2006) · AIP conference proceedings · doi:10.1063/1.2423265 · Cited by 14
Kautz, R. L. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919524 · Cited by 6
Does maternal blood cortisol entrain fetal diurnal rhythm?
Horimoto, N., Morokuma, S., & Nakano, H. (2003) · Early Human Development · doi:10.1016/j.earlhumdev.2003.10.005 · Cited by 1
Cited by
Zhang, Z., Jung, T.-P., Makeig, S., & Rao, B. D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2226175 · Cited by 340
Ryu, D., Kim, D. H., Price, J. T., Lee, J. Y., Chung, H. U., Allen, E., Walter, J. R., Jeong, H., Cao, J., Kulikova, E., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2100466118 · Cited by 105
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140783 · Cited by 42
Miniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments
Zhu, K., Shah, A. M., Berkow, J., & Kiourti, A. (2021) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2020.3019891 · Cited by 22
Metadata
- Authors
- Sameni
- Venue
- The Open Pacing, Electrophysiology & Therapy Journal
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2010
- Volume
- 3
- Pages
- 4-20
- ISSN
- 1876-536X (ISSN-L)
- OpenAlex
- W2010755794
- Cited by
- 410
- References
- 73
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.