Cryo-focused Ion Beam Sample Preparation for Imaging Vitreous Cells by Cryo-electron Tomography
Open accessThe DOI matches its Crossref record.
Abstract
Cryo-electron tomography (CET) is a well-established technique for imaging cellular and molecular structures at sub-nanometer resolution. As the method is limited to samples that are thinner than 500 nm, suitable sample preparation is required to attain CET data from larger cell volumes. Recently, cryo-focused ion beam (cryo-FIB) milling of plunge-frozen biological material has been shown to reproducibly yield large, homogeneously thin, distortion-free vitreous cross-sections for state-of-the-art CET. All eukaryotic and prokaryotic cells that can be plunge-frozen can be thinned with the cryo-FIB technique. Together with advances in low-dose microscopy, this has shifted the frontiers of in situ structural biology. In this protocol we describe the typical steps of the cryo-FIB technique, starting with fully grown cell cultures. Three recently investigated biological samples are given as examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
mTORC1 Controls Phase Separation and the Biophysical Properties of the Cytoplasm by Tuning Crowding
Delarue, M., Brittingham, G. P., Pfeffer, S., Surovtsev, I. V., Pinglay, S., Kennedy, K. J., Schaffer, M., Gutierrez, J. I., Sang, D., Poterewicz, G., et al. (2018) · Cell · doi:10.1016/j.cell.2018.05.042 · Cited by 535
Self-citationThe Eukaryotic CO2-Concentrating Organelle Is Liquid-like and Exhibits Dynamic Reorganization
Freeman Rosenzweig, E. S., Xu, B., Kuhn Cuellar, L., Martinez-Sanchez, A., Schaffer, M., Strauss, M., Cartwright, H. N., Ronceray, P., Plitzko, J. M., Förster, F., et al. (2017) · Cell · doi:10.1016/j.cell.2017.08.008 · Cited by 398
Self-citationNative architecture of the Chlamydomonas chloroplast revealed by in situ cryo-electron tomography
Engel, B. D., Schaffer, M., Kuhn Cuellar, L., Villa, E., Plitzko, J. M., & Baumeister, W. (2015) · eLife · doi:10.7554/elife.04889 · Cited by 375
Self-citationSchaffer, M., Mahamid, J., Engel, B. D., Laugks, T., Baumeister, W., & Plitzko, J. M. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.07.010 · Cited by 260
Self-citationSchaffer, M., Pfeffer, S., Mahamid, J., Kleindiek, S., Laugks, T., Albert, S., Engel, B. D., Rummel, A., Smith, A. J., Baumeister, W., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0497-5 · Cited by 257
Self-citationStructure of the membrane-assembled retromer coat determined by cryo-electron tomography
Kovtun, O., Leneva, N., Bykov, Y. S., Ariotti, N., Teasdale, R. D., Schaffer, M., Engel, B. D., Owen, D. J., Briggs, J. A. G., & Collins, B. M. (2018) · Nature · doi:10.1038/s41586-018-0526-z · Cited by 247
Self-citationIn Situ Cryo-Electron Tomography: A Post-Reductionist Approach to Structural Biology
Asano, S., Engel, B. D., & Baumeister, W. (2016) · Journal of Molecular Biology · doi:10.1016/j.jmb.2015.09.030 · Cited by 198
Self-citationDissecting the molecular organization of the translocon-associated protein complex
Pfeffer, S., Dudek, J., Schaffer, M., Ng, B. G., Albert, S., Plitzko, J. M., Baumeister, W., Zimmermann, R., Freeze, H. H., Engel, B. D., et al. (2017) · Nature Communications · doi:10.1038/ncomms14516 · Cited by 163
Self-citationProteasomes tether to two distinct sites at the nuclear pore complex
Albert, S., Schaffer, M., Beck, F., Mosalaganti, S., Asano, S., Thomas, H. F., Plitzko, J. M., Beck, M., Baumeister, W., & Engel, B. D. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716305114 · Cited by 163
Self-citationMahamid, J., Schampers, R., Persoon, H., Hyman, A. A., Baumeister, W., & Plitzko, J. M. (2015) · Journal of Structural Biology · doi:10.1016/j.jsb.2015.07.012 · Cited by 161
Self-citationIn situ architecture of the ER–mitochondria encounter structure
Wozny, M. R., Di Luca, A., Morado, D. R., Picco, A., Khaddaj, R., Campomanes, P., Ivanović, L., Hoffmann, P. C., Miller, E. A., Vanni, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06050-3 · Cited by 134
“Lamellae of vitrified yeast cells were prepared as described by 17,45 using a Scios DualBeam FIB/SEM microscope (FEI) equipped with a Quorum PP3010T cryo-FIB/SEM preparation system.”
Mind the gap: Micro-expansion joints drastically decrease the bending of FIB-milled cryo-lamellae
Wolff, G., Limpens, R. W. A. L., Zheng, S., Snijder, E. J., Agard, D. A., Koster, A. J., & Bárcena, M. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.09.006 · Cited by 115
In-cell architecture of the mitochondrial respiratory chain
Waltz, F., Righetto, R. D., Kelley, R., Zhang, X., Obr, M., Khavnekar, S., Kotecha, A., & Engel, B. D. (2024) · doi:10.1101/2024.09.03.610704 · Cited by 96
Self-citationIn-cell architecture of the mitochondrial respiratory chain
Waltz, F., Righetto, R. D., Lamm, L., Salinas-Giegé, T., Kelley, R., Zhang, X., Obr, M., Khavnekar, S., Kotecha, A., & Engel, B. D. (2025) · Science · doi:10.1126/science.ads8738 · Cited by 95
Self-citationBarad, B. A., Medina, M., Fuentes, D., Wiseman, R. L., & Grotjahn, D. A. (2023) · Journal of Cell Biology · doi:10.1083/jcb.202204093 · Cited by 81
Variable microtubule architecture in the malaria parasite
Ferreira, J. L., Pražák, V., Vasishtan, D., Siggel, M., Hentzschel, F., Binder, A. M., Pietsch, E., Kosinski, J., Frischknecht, F., Gilberger, T. W., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-36627-5 · Cited by 68
Molecular-scale visualization of sarcomere contraction within native cardiomyocytes
Burbaum, L., Schneider, J., Scholze, S., Böttcher, R. T., Baumeister, W., Schwille, P., Plitzko, J. M., & Jasnin, M. (2021) · Nature Communications · doi:10.1038/s41467-021-24049-0 · Cited by 67
Self-citationHoffmann, P. C., Giandomenico, S. L., Ganeva, I., Wozny, M. R., Sutcliffe, M., Lancaster, M. A., & Kukulski, W. (2021) · eLife · doi:10.7554/elife.70269 · Cited by 53
In-cell structural insight into the stability of sperm microtubule doublet
Tai, L., Yin, G., Huang, X., Zhu, Y., & Sun, F. (2023) · doi:10.1101/2023.05.30.542832 · Cited by 46
In-cell structural insight into the stability of sperm microtubule doublet
(2023) · doi:10.1038/s41421-023-00606-3 · Cited by 45
Metadata
- Authors
- Schaffer, M., Engel, B., Laugks, T., Mahamid, J., Plitzko, J., & Baumeister, W.
- Venue
- BIO-PROTOCOL
- Publisher
- Bio-Protocol, LLC
- Published
- 2015
- Volume
- 5
- Issue
- 17
- ISSN
- 2331-8325 (ISSN-L)
- OpenAlex
- W2431898786
- Cited by
- 132
- References
- 0
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.