The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Biosensor Recognition Elements
Open accessAbstract
Molecular recognition is central to biosensing. Since the first biosensor was developed many biosensors have been studied and developed. a biosensor can be defined as a compact analytical device or unit incorporating a biological or biologically derived sensitive recognition element integrated or associated with a physio-chemical transducer. Initially, biosensor recognition elements were isolated from living systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
PNA hybridizes to complementary oligonucleotides obeying the Watson–Crick hydrogen-bonding rules
Egholm, M., Buchardt, O., Christensen, L., Behrens, C., Freier, S. M., Driver, D. A., Berg, R. H., Kim, S. K., Norden, B., & Nielsen, P. E. (1993) · Nature · doi:10.1038/365566a0 · Cited by 2,079
Bertozzi, C. R., & Kiessling, A. L. L. (2001) · Science · doi:10.1126/science.1059820 · Cited by 1,939
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Structure-Switching Signaling Aptamers
Nutiu, R., & Li, Y. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028962o · Cited by 1,040
Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates
Sano, T., Smith, C. L., & Cantor, C. R. (1992) · Science · doi:10.1126/science.1439758 · Cited by 861
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan
Suginta, W., Khunkaewla, P., & Schulte, A. (2013) · Chemical Reviews · doi:10.1021/cr300325r · Cited by 521
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Integrated planar optical waveguide interferometer biosensors: A comparative review
Kozma, P., Kehl, F., Ehrentreich-Förster, E., Stamm, C., & Bier, F. F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.049 · Cited by 324
Liu, Q., Wang, J., & Boyd, B. J. (2015) · Talanta · doi:10.1016/j.talanta.2014.12.020 · Cited by 277
Metadata
- Venue
- Current Issues in Molecular Biology
- Publisher
- MDPI AG
- Published
- 2008
- Volume
- 10
- Issue
- 1-2
- Pages
- 1-12
- ISSN
- 1467-3037 (ISSN-L)
- OpenAlex
- W137731066
- Cited by
- 264
- References
- 49
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biosensor Recognition Elements. https://app.cochat.ai/papers/10.21775/cimb.010.001
- The paper
- Biosensor Recognition Elements. (2008). Current Issues in Molecular Biology. https://doi.org/10.21775/cimb.010.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.