The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates
Abstract
An antigen detection system, termed immuno-polymerase chain reaction (immuno-PCR), was developed in which a specific DNA molecule is used as the marker. A streptavidin-protein A chimera that possesses tight and specific binding affinity both for biotin and immunoglobulin G was used to attach a biotinylated DNA specifically to antigen-monoclonal antibody complexes that had been immobilized on microtiter plate wells. Then, a segment of the attached DNA was amplified by PCR. Analysis of the PCR products by agarose gel electrophoresis after staining with ethidium bromide allowed as few as 580 antigen molecules (9.6 × 10 -22 moles) to be readily and reproducibly detected. Direct comparison with enzyme-linked immunosorbent assay with the use of a chimera-alkaline phosphatase conjugate demonstrates that enhancement (approximately × 10 5 ) in detection sensitivity was obtained with the use of immuno-PCR. Given the enormous amplification capability and specificity of PCR, this immuno-PCR technology has a sensitivity greater than any existing antigen detection system and, in principle, could be applied to the detection of single antigen molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Semisynthetic DNA–Protein Conjugates for Biosensing and Nanofabrication
Niemeyer, C. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904930 · Cited by 369
Signal Amplification by Allosteric Catalysis
Zhu, L., & Anslyn, E. V. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501476 · Cited by 151
Immuno-PCR: An ultrasensitive immunoassay for biomolecular detection
Chang, L., Li, J., & Wang, L. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.039 · Cited by 139
Metadata
- Authors
- Sano, T., Smith, C. L., & Cantor, C. R.
- Venue
- Science
- Published
- 1992-10-02
- Volume
- 258
- Issue
- 5079
- Pages
- 120-122
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2006813546
- Cited by
- 861
- References
- 1
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates. https://app.cochat.ai/papers/10.1126/science.1439758
- The paper
- Sano, T., Smith, C. L., & Cantor, C. R. (1992). Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates. Science. https://doi.org/10.1126/science.1439758
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.