CoChat

Patient-Perceived Factors Influencing Physical Activity Sensor Use in Stroke Prevention and Rehabilitation: Systematic Review of Qualitative Studies Using Thematic Synthesis

Open access
Harris, Paul, Maine, Ingrid · 2026 · JMIR Rehabilitation and Assistive Technologies

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index; 16 of the 45 sources its claims cite were checked for support.

Abstract

Background: A robust correlation exists between physical activity (PA) and stroke risk reduction, and wearable PA sensors have emerged as promising adjuncts for rehabilitation and risk self-management. However, evidence regarding their long-term efficacy in facilitating sustained behavioral change remains equivocal. Objective: This study aimed to explore the barriers and facilitators influencing the effective use of PA sensors in older adults at risk of primary or recurrent stroke. Methods: A systematic search and thematic synthesis of qualitative research was conducted, focusing on PA sensor use among older adults at risk of primary or recurrent stroke. Given the emerging qualitative evidence base, inclusion was extended to proxy populations with analogous cardiovascular risk and functional profiles. Data were analyzed using line-by-line coding of primary text to generate descriptive themes and synthesize overarching analytical constructs. Results: A search of 6 bibliographic databases (January 2010 to December 2023) identified 18 eligible studies. This systematic review and thematic synthesis revealed predominantly technological (user experience and device attributes) and psychological (motivation) barriers. Key facilitators were psychological (feedback and motivation), technological (user experience), and social/environmental supports. Higher-level analysis revealed a critical interrelationship between effective user engagement and optimally assistive device characteristics. Conclusions: This review revealed a synergistic user-device interaction driving sustained PA in older adults at risk of primary or recurrent stroke. Future interventions developed in collaboration with patients and informed by the factors identified by this study will improve participation in rehabilitation and functional outcomes in this population.

Overview

CoChat Summary

TL;DR

This systematic review and thematic synthesis examined qualitative evidence on older adults’ perceptions of wearable physical activity sensors in stroke prevention and rehabilitation. Across 18 studies, the main takeaways were that sustained use depends on a synergy between user engagement, support, and device features such as usability, comfort, and accuracy.

Key findings

  • The search of 6 bibliographic databases identified 18 eligible studies, and the review found predominantly technological barriers (user experience and device attributes) and psychological barriers (motivation).
  • Major facilitator themes were psychological, technological, and support-related; in the reported coding density summary, facilitators comprised 60% of themes, with motivation the most common facilitator category (31.2% of facilitator themes).
  • Major barrier themes were largely technological: user experience (24.5% of barrier themes) and device attributes (20.1%), plus psychological motivation barriers (15.6%).
  • The synthesis produced 2 higher-level analytical constructs: a person-centric “effective user engagement” construct and a device-centric “optimally assistive device” construct, suggesting a synergistic relationship between user engagement and device characteristics.

Methods

  • Systematic review and thematic synthesis of qualitative research, conducted and reported according to PRISMA and the JBI framework; study quality was evaluated using CASP and JBI critical appraisal tools.
  • Searches were run in MEDLINE, EMBASE, CINAHL, Cochrane, PsycINFO, and Scopus for English-language peer-reviewed articles from January 1, 2010 to December 31, 2023; 648 records were retrieved from databases and 63 additional records from manual harvesting.
  • Included studies had a qualitative design or significant qualitative component and focused on wearable PA sensor use in older adults at risk of primary or recurrent stroke or proxy populations with analogous risk/functional profiles; analysis used line-by-line coding, descriptive themes, and higher-level analytical constructs.

Limitations

  • The paper states that only 2 included studies specifically addressed older stroke survivors: a qualitative study of 15 survivors and a systematic review incorporating one qualitative stroke study and 5 qualitative proxy-population studies.
  • The authors note that qualitative interpretation is subjective, so the synthesis may represent only one of several possible frameworks.
  • The lack of detailed technical specifications across included PA sensors prevented analysis of device-specific effects such as wearability or discrete usability features.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2196/86915

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) flow diagram for systematic reviews.
Figure 1. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) flow diagram for systematic reviews.CC BY · PubMed Central
Figure 2. Major barrier/facilitator descriptive and substrate themes. Dev. attr.: device attributes; Neurophys.: neurophysiological
Figure 2. Major barrier/facilitator descriptive and substrate themes. Dev. attr.: device attributes; Neurophys.: neurophysiologicalCC BY · PubMed Central
Figure 3. Major barrier clustering by descriptive theme.
Figure 3. Major barrier clustering by descriptive theme.CC BY · PubMed Central
Figure 4. Major facilitator clustering by descriptive theme.
Figure 4. Major facilitator clustering by descriptive theme.CC BY · PubMed Central
Figure 5. High-level analytical constructs.
Figure 5. High-level analytical constructs.CC BY · PubMed Central

Verification

Claims the paper makes

12 Valid · 4 Not valid · 24 Not checked · 88 Own results and interpretations

52 more claims

Create a free account to see all 128 claims and to verify the 1 reference still open.

See all claims — free account
  • It may state two separate claims as one. 34
  • Probably not a substantial claim. 46
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 43 references

Research works printed but not linked: 1

  1. Booth A Papaioannou D Sutton A Systematic Approaches to a Successful Literature Review SAGE Publications 2012 URL https://www.researchgate.net/profile/Andrew-Booth-2/publication/235930866_Systematic_Approaches_to_a_Successful_Literature_Review/links/5da06c7f45851553ff8705fa/Systematic-Approaches-to-a-Successful-Literature-Review.pdf Accessed 21-02-2026 ISBN 978-1-4739-1246-5

Metadata

Authors
Harris, P., & Maine, I.
Affiliations
The University of Melbourne (AU)
Corresponding author
Harris, Paul
Venue
JMIR Rehabilitation and Assistive Technologies
Published
2026-03-12
Volume
13
Pages
e86915-e86915
ISSN
2369-2529 (ISSN-L)
OpenAlex
W7128517049
Cited by
1
References
37
Citations by year
2026: 1
FWCI
0.99
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • JMIR Rehabilitation and Assistive Technologies (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
wearable activity trackers, physical activity, stroke prevention, stroke rehabilitation, older adults, barriers and facilitators, user motivation, user experience, feedback, social support, user engagement, assistive devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.