Clinical Decision Support Systems for Drug Allergy Checking: Systematic Review
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Worldwide, the burden of allergies-in particular, drug allergies-is growing. In the process of prescribing, dispensing, or administering a drug, a medication error may occur and can have adverse consequences; for example, a drug may be given to a patient with a documented allergy to that particular drug. Computerized physician order entry (CPOE) systems with built-in clinical decision support systems (CDSS) have the potential to prevent such medication errors and adverse events. OBJECTIVE: The aim of this review is to provide a comprehensive overview regarding all aspects of CDSS for drug allergy, including documenting, coding, rule bases, alerts and alert fatigue, and outcome evaluation. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed as much as possible and searches were conducted in 5 databases using CPOE, CDSS, alerts, and allergic or allergy as keywords. Bias could not be evaluated according to PRISMA guidelines due to the heterogeneity of study types included in the review. RESULTS: Of the 3160 articles considered, 60 met the inclusion criteria. A further 9 articles were added based on expert opinion, resulting in a total of 69 articles. An interrater agreement of 90.9% with a reliability Κ=.787 (95% CI 0.686-0.888) was reached. Large heterogeneity across study objectives, study designs, study populations, and reported results was found. Several key findings were identified. Evidence of the usefulness of clinical decision support for drug allergies has been documented. Nevertheless, there are some important problems associated with their use. Accurate and structured documenting of information on drug allergies in electronic health records (EHRs) is difficult, as it is often not clear to healthcare providers how and where to document drug allergies. Besides the underreporting of drug allergies, outdated or inaccurate drug allergy information in EHRs poses an important problem. Research on the use of coding terminologies for documenting drug allergies is sparse. There is no generally accepted standard terminology for structured documentation of allergy information. The final key finding is the consistently reported low specificity of drug allergy alerts. Current systems have high alert override rates of up to 90%, leading to alert fatigue. Important challenges remain for increasing the specificity of drug allergy alerts. We found only one study specifically reporting outcomes related to CDSS for drug allergies. It showed that adverse drug events resulting from overridden drug allergy alerts do not occur frequently. CONCLUSIONS: Accurate and comprehensive recording of drug allergies is required for good use of CDSS for drug allergy screening. We found considerable variation in the way drug allergy are recorded in EHRs. It remains difficult to reduce drug allergy alert overload while maintaining patient safety as the highest priority. Future research should focus on improving alert specificity, thereby reducing override rates and alert fatigue. Also, the effect on patient outcomes and cost-effectiveness should be evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Garg, A. X., Adhikari, N. K. J., McDonald, H., Rosas-Arellano, M. P., Devereaux, P. J., Beyene, J., Sam, J., & Haynes, R. B. (2005) · JAMA · doi:10.1001/jama.293.10.1223 · Cited by 2,936
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Overriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Relationship between medication errors and adverse drug events
Bates, D. W., Boyle, D. L., Vliet, M. B. V., Schneider, J., & Leape, L. (1995) · Journal of General Internal Medicine · doi:10.1007/bf02600255 · Cited by 981
Macy, E., & Contreras, R. (2014) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2013.09.021 · Cited by 829
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763
Improving Acceptance of Computerized Prescribing Alerts in Ambulatory Care
Shah, N. R., Seger, A. C., Seger, D. L., Fiskio, J. M., Kuperman, G. J., Blumenfeld, B., Recklet, E. G., Bates, D. W., & Gandhi, T. K. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1868 · Cited by 353
Kesselheim, A. S., Cresswell, K., Phansalkar, S., Bates, D. W., & Sheikh, A. (2011) · Health Affairs · doi:10.1377/hlthaff.2010.1111 · Cited by 277
Cited by
An overview of clinical decision support systems: Benefits, risks, and strategies for success
Sutton, R. T., Pincock, D., Baumgart, D. C., Sadowski, D. C., Fedorak, R. N., & Kroeker, K. I. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0221-y · Cited by 3,019
“However; even allergy alerts can be incorrect, and clinicians will often verify themselves, especially if the source is another site/hospital/ practitioner.(85,87) Medication alerts can also be specialty specific, but irrelevant when taken out of context.”
BackgroundClinical Decision Support and Implications for the Clinician Burnout Crisis
Jankovic, I., & Chen, J. H. (2020) · Yearbook of Medical Informatics · doi:10.1055/s-0040-1701986 · Cited by 84
Tao, L., Zhang, C., Zeng, L., Zhu, S., Li, N., Li, W., Zhang, H., Zhao, Y., Zhan, S., & Ji, H. (2020) · JMIR Medical Informatics · doi:10.2196/16912 · Cited by 42
“A range of systematic reviews, meta-analyses, or synthesis of systematic reviews have summarized the effects of CDSS in chemotherapy processes [33], cardiovascular risk factors [24], drug allergy checks [34], patient outcomes [15,17], acute care management [35], primary preventive care [36], and chronic disease manage…”
BackgroundKhalifa, M., Magrabi, F., & Gallego Luxan, B. (2020) · Journal of Medical Internet Research · doi:10.2196/15770 · Cited by 6
Chen, J., Cutrona, S. L., Dharod, A., Bunch, S. C., Foley, K. L., Ostasiewski, B., Hale, E. R., Bridges, A., Moses, A., Donny, E. C., et al. (2023) · JMIR Medical Informatics · doi:10.2196/43097 · Cited by 4
“However, effective implementation of alerts into the clinical workflow is nontrivial [28-32].”
Background
Metadata
- Authors
- Légat, L., Van Laere, S., Nyssen, M., Steurbaut, S., Dupont, A. G., & Cornu, P.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2018-09-07
- Volume
- 20
- Issue
- 9
- Pages
- e258
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W2809239485
- Cited by
- 94
- References
- 22
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.