Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its OpenAlex record; 16 of the 16 references it cites were found in a registry or an index.

Laboratory Parameters in Detection of COVID-19 Patients with Positive RT-PCR; a Diagnostic Accuracy Study.

Open access
Rajab Mardani, Abbas Ahmadi Vasmehjani, Fatemeh Zali, Alireza Gholami, Seyed Dawood Mousavi Nasab, Hooman Kaghazian, Mehdi Kaviani, Nayebali Ahmadi · 2020 · Archives of Academic Emergency Medicine

Abstract

INTRODUCTION: The role of laboratory parameters in screening of COVID-19 cases has not been definitely established. This study aimed to evaluate the accuracy of laboratory parameters in predicting cases with positive RT-PCR for COVID-19. METHODS: This diagnostic accuracy study was conducted on suspected COVID-19 patients, who presented to Behpooyan Clinic Medical center in Tehran (Iran) from 22 February to 14 March, 2020. Patients were divided into two groups based on the results of real time reverse transcriptase-polymerase chain reaction (RT-PCR) for COVID-19, and the accuracy of different laboratory parameters in predicting cases with positive RT-PCR was evaluated using area under the ROC curve (AUC). RESULTS: Two hundred cases with the mean age of 41.3± 14.6 (range: 19-78) years were studied (0.53% male). The result of RT-PCR for COVID-19 was positive in 70 (35%) cases. Patients with positive RT-PCR had significantly higher neutrophil (NEU) count (p = 0.0001), and C-reactive protein (CRP) (p = 0.04), lactate dehydrogenase (LDH) (p = 0.0001), aspartate aminotransferase (AST) (p = 0.001), alanine aminotransferase (ALT) (p = 0.0001), and Urea (p = 0.001) levels in serum. In addition, patients with positive RT-PCR had lower white blood cell (WBC) count (p = 0.0001) and serum albumin level (p = 0.0001) compared to others. ALT (AUC = 0.879), CRP (AUC = 0.870), NEU (AUC = 0.858), LDH (AUC = 0.835), and Urea (AUC = 0.835) had very good accuracy in predicting cases with positive RT-PCR for COVID-19, respectively. CONCLUSION: Our findings suggest that level of LDH, CRP, ALT and NEU can be used to predict the result of COVID-19 test. They can help in detection of COVID-19 patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.22037/aaem.v8i1.632

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 271

Metadata

Authors
Mardani, R., Vasmehjani, A. A., Zali, F., Gholami, A., Nasab, S. D. M., Kaghazian, H., Kaviani, M., & Ahmadi, N.
Venue
Archives of Academic Emergency Medicine
Published
2020-01-01
Volume
8
Issue
1
Pages
e43-e43
ISSN
2645-4904 (ISSN-L)
OpenAlex
W3014911098
Cited by
271
References
16
FWCI
7.57
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Parameters in Detection of COVID-19 Patients with Positive RT-PCR; a Diagnostic Accuracy Study. https://app.cochat.ai/papers/10.22037/aaem.v8i1.632
The paper
Mardani, R., Vasmehjani, A. A., Zali, F., Gholami, A., Nasab, S. D. M., Kaghazian, H., Kaviani, M., & Ahmadi, N. (2020). Laboratory Parameters in Detection of COVID-19 Patients with Positive RT-PCR; a Diagnostic Accuracy Study. Archives of Academic Emergency Medicine. https://doi.org/10.22037/aaem.v8i1.632

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.