Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record.

Isotropic MRI of the Knee with 3D Fast Spin-Echo Extended Echo-Train Acquisition (XETA): Initial Experience

Gold, Garry E., Busse, Reed F., Beehler, Carol, Han, Eric, Brau, Anja C. S., Beatty, Philip J., Beaulieu, Christopher F.·2007·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of our study was to prospectively compare a recently developed method of isotropic 3D fast spin-echo (FSE) with extended echo-train acquisition (XETA) with 2D FSE and 2D fast recovery FSE (FRFSE) for MRI of the knee. SUBJECTS AND METHODS: Institutional review board approval, Health Insurance Portability and Accounting Act (HIPAA) compliance, and informed consent were obtained. We studied 10 healthy volunteers and one volunteer with knee pain using 3D FSE XETA, 2D FSE, and 2D FRFSE. Images were obtained both with and without fat suppression. Cartilage and muscle signal-to-noise ratio (SNR) and cartilage-fluid contrast-to-noise ratio (CNR) were compared using a Student's t test. We also compared reformations of 3D FSE XETA with 2D FSE images directly acquired in the axial plane. RESULTS: Cartilage SNR was higher with 3D FSE XETA (56.8 +/- 9 [SD]) compared with the 2D FSE (45.8 +/- 8, p < 0.01) and 2D FRFSE (32.5 +/- 5.3, p < 0.01). Muscle SNR was significantly higher with 3D FSE XETA (52.1 +/- 4.3) than 2D FSE (45.2 +/- 9, p < 0.01) and 2D FRFSE (23.6 +/- 6.2, p < 0.01). Fluid SNR was significantly higher for 2D FSE (144.9 +/- 33) than 3D FSE XETA (104.7 +/- 18, p < 0.01). Compared with 2D FSE and 2D FRFSE, 3D FSE XETA had lower cartilage-fluid CNR due to higher cartilage SNR (p < 0.01). Three-dimensional FSE XETA acquired volumetric data sets with isotropic resolution. Reformatted images in the axial plane were similar to axial 2D FSE acquisitions but with thinner slices. CONCLUSION: Three-dimensional FSE XETA acquires high-resolution (approximately 0.7 mm) isotropic data with intermediate and T2-weighting that may be reformatted in arbitrary planes. Three-dimensional FSE XETA is a promising technique for MRI of the knee.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.06.1208

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 191

Metadata

Authors
Gold, G. E., Busse, R. F., Beehler, C., Han, E., Brau, A. C. S., Beatty, P. J., & Beaulieu, C. F.
Venue
American Journal of Roentgenology
Published
2007-05
Volume
188
Issue
5
Pages
1287-1293
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2135619566
Cited by
191
References
0
FWCI
10.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isotropic MRI of the Knee with 3D Fast Spin-Echo Extended Echo-Train Acquisition (XETA): Initial Experience. https://app.cochat.ai/papers/10.2214/ajr.06.1208
The paper
Gold, G. E., Busse, R. F., Beehler, C., Han, E., Brau, A. C. S., Beatty, P. J., & Beaulieu, C. F. (2007). Isotropic MRI of the Knee with 3D Fast Spin-Echo Extended Echo-Train Acquisition (XETA): Initial Experience. American Journal of Roentgenology. https://doi.org/10.2214/ajr.06.1208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.