CoChat

Qualitative Comparison of 3-T and 1.5-T MRI in the Evaluation of Epilepsy

Phal, Pramit M., Usmanov, Alexander, Nesbit, Gary M., Anderson, James C., Spencer, David, Wang, Paul, Helwig, Jonathan A., Roberts, Colin, Hamilton, Bronwyn E. · 2008 · American Journal of Roentgenology
Cited by 160

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: MRI at 3 T, which has a higher signal-to-noise ratio than 1.5-T MRI, is potentially more sensitive and specific at delineating epileptogenic lesions and may influence management of refractory epilepsy. The purposes of the current study were to compare image quality of 3-T MRI with that of 1.5-T MRI in the evaluation of epilepsy and, in cases of focal epilepsy, to compare the two field strengths in terms of lesion detection and characterization. MATERIALS AND METHODS: Retrospective review was performed on 50 sets of MR images of 25 patients who underwent both 3-T and 1.5-T brain imaging with a dedicated epilepsy protocol, including fast spin-echo T2-weighted, coronal FLAIR, coronal fast multiplanar inversion recovery, and 3D spoiled gradient-recalled echo pulse sequences. Parameters assessed were distortion and artifact, lesion conspicuity, gray-white matter differentiation, and motion. Each pulse sequence was graded on a 4-point scale. Reviewers performed qualitative assessments of the site of abnormality and the most likely diagnosis. RESULTS: MRI at 3 T outperformed MRI at 1.5 T in all four parameters and was statistically superior (p < 0.05) to 1.5-T MRI in all categories except motion. On 3-T MRI, lesions were detected in 65 of 74 cases compared with 55 of 74 cases at 1.5 T (p = 0.0364), and lesions were accurately characterized in 63 of 74 cases compared with 51 of 74 cases at 1.5 T (p = 0.0194). The odds ratios showed identification of a focal epileptogenic lesion with 3-T MRI 2.57 times as likely as identification with 1.5-T MRI and accurate characterization of lesions 2.66 times as likely as characterization with 1.5-T MRI. CONCLUSION: In evaluation of epilepsy, MRI at 3 T performed better than 1.5-T MRI in image quality, detection of structural lesions, and characterization of lesions. High-field-strength imaging should be considered for patients with intractable epilepsy and normal or equivocal findings on 1.5-T MRI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.07.3933

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

Metadata

Authors
Phal, P. M., Usmanov, A., Nesbit, G. M., Anderson, J. C., Spencer, D., Wang, P., Helwig, J. A., Roberts, C., & Hamilton, B. E.
Venue
American Journal of Roentgenology
Published
2008-09
Volume
191
Issue
3
Pages
890-895
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2098413901
Cited by
160
References
15
FWCI
5.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.