High-Intensity Focused Ultrasound Ablation: Effective and Safe Therapy for Solid Tumors in Difficult Locations
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to evaluate the safety and efficacy of ultrasound-guided high-intensity focused ultrasound therapeutic ablation of solid tumors in difficult locations. SUBJECTS AND METHODS: A procedure was performed with a focused ultrasound tumor therapeutic system which provides real-time ultrasound guidance. All patients underwent MDCT or MRI, and some patients underwent PET/CT. From November 2007 through April 2009, 31 patients with 38 lesions of the liver and pancreas in difficult locations were treated. Six patients had hepatocellular carcinoma, 13 patients had hepatic metastasis from colorectal cancer, two had hepatic metastases of breast cancer, two had hepatic metastasis of neuroendocrine tumors, one patient had lymph node metastasis of breast cancer at the hepatic hilum, six patients had pancreatic cancer, and one patient had a neuroendocrine tumor. Difficult location was defined as tumor adjacent to a main blood vessel, the heart, the gallbladder and bile ducts, the bowel, or the stomach. RESULTS: The mean diameter of tumors was 2.7 +/- 1.4 cm. PET/CT, MDCT, or both on the day after one session of high-intensity focused ultrasound treatment showed complete response in all six patients with hepatocellular carcinoma, the patient with lymph node metastasis, and 22 of 24 patients with hepatic metastasis. The symptoms of all seven patients with pancreatic caner or neuroendocrine tumors were palliated, and PET/CT or MRI showed complete response of six of seven lesions. Portal vein thrombosis occurred after high-intensity focused ultrasound ablation in one patient with pancreatic cancer. No other side effects were detected in a median follow-up period of 12 months. CONCLUSION: According to our short- and long-term follow-up results, ultrasound-guided high-intensity focused ultrasound ablation can be considered a safe and feasible approach to the management of solid tumors in difficult locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer: Principles and Practice of Oncology.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-819_4 · Cited by 8,516
Llovet, J. M., Real, M. I., Montaña, X., Planas, R., Coll, S., Aponte, J., Ayuso, C., Sala, M., Muchart, J., Solà, R., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08649-x · Cited by 3,494 · cited 1×
“Radiofrequency ablation (RFA), percutaneous ethanol injection, cryoablation, microwave coagulation, and laser-induced interstitial thermotherapy also can result in local tumor control, and use of these treatments occasionally leads to long-term disease-free survival [3–5].”
BackgroundSociety of Interventional Radiology Clinical Practice Guidelines
Sacks, D., McClenny, T. E., Cardella, J. F., & Lewis, C. A. (2003) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000094584.83406.3e · Cited by 1,714 · cited 1×
“Adverse Events The adverse events and complications were categorized according to the Society of Interventional Radiology classification system for complications by outcome [22].”
MethodHigh-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282 · cited 1×
“High-intensity focused ultrasound has received considerable attention for the management of solid tumors [11].”
BackgroundA NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY
Lynn, J. G., Zwemer, R. L., Chick, A. J., & Miller, A. E. (1942) · Journal of General Physiology · doi:10.1085/jgp.26.2.179 · Cited by 690
Illing, R. O., Kennedy, J. E., Wu, F., ter Haar, G. R., Protheroe, A. S., Friend, P. J., Gleeson, F. V., Cranston, D. W., Phillips, R. R., & Middleton, M. R. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602803 · Cited by 584 · cited 3×
“In Oxford, England, a total of 22 patients with liver metastasis were treated with ultrasoundguided high-intensity focused ultrasound [14], and 20 of the 22 underwent imaging (MRI or contrast ultrasound) or histologic assessment.”
BackgroundChemoembolization for hepatocellular carcinoma
Bruix, J., Sala, M., & Llovet, J. M. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.09.032 · Cited by 569
High-intensity focused ultrasound for the treatment of liver tumours
Kennedy, J. E., Wu, F., ter Haar, G. R., Gleeson, F. V., Phillips, R. R., Middleton, M. R., & Cranston, D. (2004) · Ultrasonics · doi:10.1016/j.ultras.2004.01.089 · Cited by 435 · cited 1×
“In earlier studies [14, 31] mild discomfort or local pain was found in 54–80% of treated patients.”
BackgroundSustained Relief of Leiomyoma Symptoms by Using Focused Ultrasound Surgery
Stewart, E. A., Gostout, B., Rabinovici, J., Kim, H. S., Regan, L., & Tempany, C. M. C. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000275283.39475.f6 · Cited by 332 · cited 1×
“The results showed MRI-guided focused ultrasound ablation feasible and safe for that purpose [20, 21].”
BackgroundWu, F., Wang, Z.-B., Chen, W.-Z., Wang, W., Gui, Y., Zhang, M., Zheng, G., Zhou, Y., Xu, G., Li, M., et al. (2004) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2004.01.011 · Cited by 313 · cited 1×
“In the largest series of clinical application of highintensity focused ultrasound to date [16], 1,038 patients were treated with ultrasound-guided high-intensity focused ultrasound in 10 centers for both curative and palliative purposes, and the results were promising.”
BackgroundSelf-citation
Cited by
Present and future of metal nanoparticles in tumor ablation therapy
Lou, W., Xie, L., Xu, L., Xu, M., Xu, F., Zhao, Q., & Jiang, T. (2023) · Nanoscale · doi:10.1039/d3nr04362b · Cited by 33
Metadata
- Authors
- Orsi, F., Zhang, L., Arnone, P., Orgera, G., Bonomo, G., Vigna, P. D., Monfardini, L., Zhou, K., Chen, W., Wang, Z., & Veronesi, U.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2010-09
- Volume
- 195
- Issue
- 3
- Pages
- W245-W252
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2019679760
- Cited by
- 176
- References
- 23
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Intensity Focused Ultrasound Ablation: Effective and Safe Therapy for Solid Tumors in Difficult Locations. https://app.cochat.ai/papers/10.2214/ajr.09.3321
- The paper
- Orsi, F., Zhang, L., Arnone, P., Orgera, G., Bonomo, G., Vigna, P. D., Monfardini, L., Zhou, K., Chen, W., Wang, Z., & Veronesi, U. (2010). High-Intensity Focused Ultrasound Ablation: Effective and Safe Therapy for Solid Tumors in Difficult Locations. American Journal of Roentgenology. https://doi.org/10.2214/ajr.09.3321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.