CoChat

Signal Change in the Dentate Nucleus on T1-Weighted MR Images After Multiple Administrations of Gadopentetate Dimeglumine Versus Gadobutrol

Cao, Yan, Huang, Daisy Q., Shih, George, Prince, Martin R. · 2016 · American Journal of Roentgenology
Cited by 162

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The objective of this study was to evaluate signal changes in the dentate nucleus on unenhanced T1-weighted MR images after multiple administrations of gadopentetate dimeglumine versus gadobutrol. MATERIALS AND METHODS: Two study groups were identified, each of which included 25 consecutive patients. Each group received six or more administrations of either gadobutrol only or gadopentetate dimeglumine only, without having had exposure to any other gadolinium-based contrast agent (GBCA). The mean signal intensity (SI) in the dentate nucleus on unenhanced T1-weighted MR images was measured, with the use of the pons and the cerebellar peduncle as references to calculate the DNP SI ratio (i.e., the ratio of the SI in the dentate nucleus to the SI in the pons) and the DCP SI ratio (i.e., the ratio of the SI in the dentate nucleus to the SI in the cerebellar peduncle). RESULTS: After six administrations of gadopentetate dimeglumine, the SI in the dentate nucleus on unenhanced T1-weighted MR images increased from a DCP SI ratio of 0.997 before administration to 1.034 after the last of six administrations (p = 0.0007) and then to 1.063 after all administrations (p = 0.0004). No statistically significant increase was noted in association with administration of gadobutrol, for which the DCP SI ratio was 0.995 before administration, 1.009 after the last of six administrations (p = 0.1172), and 0.992 after all administrations (p = 0.7592). The change in the DCP SI ratio after administration of gadopentetate dimeglumine correlated with the number of administrations the patient received (p < 0.0001). CONCLUSION: Unenhanced T1 signal hyperintensity was observed in the dentate nucleus after multiple administrations of gadopentetate dimeglumine, a linear ionic agent, but not after multiple administrations of gadobutrol, a macrocyclic GBCA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.15.15327

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 162

Metadata

Authors
Cao, Y., Huang, D. Q., Shih, G., & Prince, M. R.
Venue
American Journal of Roentgenology
Published
2016-02
Volume
206
Issue
2
Pages
414-419
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2208386561
Cited by
162
References
15
FWCI
13.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.