Computer vision and artificial intelligence in mammography.
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The revolution in digital computer technology that has made possible new and sophisticated imaging techniques may next influence the interpretation of radiologic images. In mammography, computer vision and artificial intelligence techniques have been used successfully to detect or to characterize abnormalities on digital images. Radiologists supplied with this information often perform better at mammographic detection or characterization tasks in observer studies than do unaided radiologists. This technology therefore could decrease errors in mammographic interpretation that continue to plague human observers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ballard, D. H., & Brown, C. M. (1982) · Cited by 5,303
Adaptive pattern recognition and neural networks
(1989) · Choice Reviews Online · doi:10.5860/choice.26-6311 · Cited by 2,313
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931
Analysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820
Periodic mammographic follow-up of probably benign lesions: results in 3,184 consecutive cases.
Sickles, E. A. (1991) · Radiology · doi:10.1148/radiology.179.2.2014293 · Cited by 555
The positive predictive value of mammography.
Kopans, D. B. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.158.3.1310825 · Cited by 413
Lung cancer detected during a screening program using four-month chest radiographs.
Muhm, J. R., Miller, W. E., Fontana, R. S., Sanderson, D. R., & Uhlenhopp, M. A. (1983) · Radiology · doi:10.1148/radiology.148.3.6308709 · Cited by 344
Chan, H.-P., Doi, K., Galhotra, S., Vyborny, C. J., MacMahon, H., & Jokich, P. M. (1987) · Medical Physics · doi:10.1118/1.596065 · Cited by 342
Self-citationComputer-aided mammographic screening for spiculated lesions.
Kegelmeyer, W. P., Pruneda, J. M., Bourland, P. D., Hillis, A., Riggs, M. W., & Nipper, M. L. (1994) · Radiology · doi:10.1148/radiology.191.2.8153302 · Cited by 278
Breast cancer missed by mammography
Martin, J., Moskowitz, M., & Milbrath (1979) · American Journal of Roentgenology · doi:10.2214/ajr.132.5.737 · Cited by 246
An approach to automated detection of tumors in mammograms
Brzakovic, D., Luo, X. M., & Brzakovic, P. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.57760 · Cited by 246
Winsberg, F., Elkin, M., Macy, J., Bordaz, V., & Weymouth, W. (1967) · Radiology · doi:10.1148/89.2.211 · Cited by 237 · cited 1×
“Winsberg and coworkers, the first published investigators in this field [27], were motivated by the problems inherent in the routine viewing of large volumes of screening mammograms performed on asymptomatic women, even before the validity of such screening had become well established [28].”
BackgroundTuddenham, W. J. (1962) · Radiology · doi:10.1148/78.5.694 · Cited by 205
Computerized detection of masses in digital mammograms: Analysis of bilateral subtraction images
Yin, F., Giger, M. L., Doi, K., Metz, C. E., Vyborny, C. J., & Schmidt, R. A. (1991) · Medical Physics · doi:10.1118/1.596610 · Cited by 196
Self-citationEnhanced Interpretation of Diagnostic Images
GETTY, D. J., PICKETT, R. M., D??ORSI, C. J., & SWETS, J. A. (1988) · Investigative Radiology · doi:10.1097/00004424-198804000-00002 · Cited by 165
Wu, Y. C., Doi, K., Giger, M. L., & Nishikawa, R. M. (1992) · Medical Physics · doi:10.1118/1.596845 · Cited by 154
Self-citationEffect of case selection on the performance of computer‐aided detection schemes
Nishikawa, R. M., Giger, M. L., Doi, K., Metz, C. E., Yin, F.-F., Vyborny, C. J., & Schmidt, R. A. (1994) · Medical Physics · doi:10.1118/1.597287 · Cited by 148
Self-citationAutomatic computer detection of clustered calcifications in digital mammograms
Davies, D. H., & Dance, D. R. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/8/007 · Cited by 138
Digital image processing: effect on detectability of simulated low-contrast radiographic patterns.
Ishida, M., Doi, K., Loo, L. N., Metz, C. E., & Lehr, J. L. (1984) · Radiology · doi:10.1148/radiology.150.2.6691118 · Cited by 134
Enhancing and Evaluating Diagnostic Accuracy
Swets, J. A., Getty, D. J., Pickett, R. M., D'Orsi, C. J., Seltzer, S. E., & McNeil, B. J. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100102 · Cited by 113
Giger, M. L., Ahn, N., Doi, K., MacMahon, H., & Metz, C. E. (1990) · Medical Physics · doi:10.1118/1.596478 · Cited by 94
Self-citationYIN, F.-F., GIGER, M. L., VYBORNY, C. J., DOI, K., & SCHMIDT, R. A. (1993) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199306000-00001 · Cited by 94
Self-citationToward a unified view of radiological imaging systems. Part II: Noisy images
Wagner, R. F. (1977) · Medical Physics · doi:10.1118/1.594362 · Cited by 86
Breast cancer detection: one versus two views.
Bassett, L. W., Bunnell, D. H., Jahanshahi, R., Gold, R. H., Arndt, R., & Linsman, J. (1987) · Radiology · doi:10.1148/radiology.165.1.3628795 · Cited by 77
Algorithm for the detection of fine clustered calcifications on film mammograms.
Fam, B. W., Olson, S. L., Winter, P. F., & Scholz, F. J. (1988) · Radiology · doi:10.1148/radiology.169.2.3174981 · Cited by 69
A fully automated system for screening xeromammograms
Semmlow, J. L., Shadagopappan, A., Ackerman, L. V., Hand, W., & Alcorn, F. S. (1980) · Computers and Biomedical Research · doi:10.1016/0010-4809(80)90027-0 · Cited by 60
Mammogram Inspection by Computer
Spiesberger, W. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326560 · Cited by 58
Expert system-controlled image display.
Swett, H. A., Fisher, P. R., Cohn, A. I., Miller, P. L., & Mutalik, P. G. (1989) · Radiology · doi:10.1148/radiology.172.2.2664871 · Cited by 58
Reading and decision aids for improved accuracy and standardization of mammographic diagnosis.
D’Orsi, C. J., Getty, D. J., Swets, J. A., Pickett, R. M., Seltzer, S. E., & McNeil, B. J. (1992) · Radiology · doi:10.1148/radiology.184.3.1509042 · Cited by 57
ICON: a computer-based approach to differential diagnosis in radiology.
Swett, H. A., & Miller, P. L. (1987) · Radiology · doi:10.1148/radiology.163.2.3550885 · Cited by 57
Teleradiology/Telepathology requirements and implementation
Mun, S. K., Elsayed, A. M., Tohme, W. G., & Wu, Y. C. (1995) · Journal of Medical Systems · doi:10.1007/bf02257066 · Cited by 55
Computer screening of xeromammograms: A technique for defining suspicious areas of the breast
Hand, W., Semmlow, J. L., Ackerman, L. V., & Alcorn, F. S. (1979) · Computers and Biomedical Research · doi:10.1016/0010-4809(79)90031-4 · Cited by 52
Automatic Detection of Suspicious Abnormalities in Breast Radiographs
Kimme‐Smith, C., O'Loughlin, B. J., & Sklansky, J. (1977) · Elsevier eBooks · doi:10.1016/b978-0-12-415050-8.50019-7 · Cited by 51
Automated detection and classification of breast tumors
Ng, S. L. A., & Bischof, W. F. (1992) · Computers and Biomedical Research · doi:10.1016/0010-4809(92)90040-h · Cited by 50
Peripheral Vision, Structured Noise and Film Reader Error
Kundel, H. L. (1975) · Radiology · doi:10.1148/114.2.269 · Cited by 44
Qian, W., Clarke, L. P., Kallergi, M., Li, H. D., Velthuizen, R. P., Clark, R. A., & Silbiger, M. L. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148665 · Cited by 43
Nishikawa, R. M., Giger, M. L., Doi, K., Vyborny, C. J., Schmidt, R. A., Metz, C. E., Wu, C. Y., Yin, F.-F., Jiang, Y., Huo, Z., et al. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148655 · Cited by 40
Self-citationComputer-aided detection of clustered microcalcifications in digitized mammograms
Zheng, B., Chang, Y., Staiger, M. J., Good, W. F., & Gur, D. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80431-3 · Cited by 40
Brenner, R. J. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.156.4.2003433 · Cited by 39
Mammogram interpretation by physician assistants
Hillman, B., Fajardo, L., Hunter, T., Mockbee, B., Cook, C., Hagaman, R. M., Bjelland, J. C., Frey, C., & Harris, C. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.5.907 · Cited by 36
Automation in mammography: computer vision and human perception
Astley, S., Hutt, I., Adamson, S., Miller, P., Rose, P., Boggis, C. R. M., Taylor, C., Valentine, T., Davies, J. D., & Armstrong, J. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148683 · Cited by 32
Automated recognition of microcalcification clusters in mammograms
Bankman, I. N., Christens‐Barry, W. A., Kim, D.-W., Weinberg, I. N., Gatewood, O. B., & Brody, W. R. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148684 · Cited by 19
Automatic detection and classification system for calcifications in mammograms
Shen, L. C., Rangayyan, R. M., & Desautels, J. E. L. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.148691 · Cited by 12
Cited by
American Cancer Society Guidelines for Breast Cancer Screening: Update 2003
Smith, R. A., Saslow, D., Andrews Sawyer, K., Burke, W., Costanza, M. E., Evans, W. P., Foster, R. S., Hendrick, E., Eyre, H. J., & Sener, S. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.3.141 · Cited by 770
Potential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 554
Self-citationA review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationAutomated computerized classification of malignant and benign masses on digitized mammograms
Huo, Z., Giger, M. L., Vyborny, C. J., Wolverton, D. E., Schmidt, R. A., & Doi, K. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80278-x · Cited by 167
Self-citation
Metadata
- Authors
- Vyborny, C. J., & Giger, M. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1994-03
- Volume
- 162
- Issue
- 3
- Pages
- 699-708
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1972536364
- Cited by
- 181
- References
- 43
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.