MR contrast material for vascular enhancement: value of superparamagnetic iron oxide.
The DOI matches its Crossref record.
Abstract
OBJECTIVE: The purpose of this study were to quantify abdominal vascular enhancement and to prove the feasibility of iron oxide-enhanced MR angiography in humans using three doses of superparamagnetic iron oxide agent AMI 227. SUBJECTS AND METHODS: Sixteen patients randomly received either 0.8, 1.1, or 1.7 mg Fe/kg of ultrasmall superparamagnetic iron oxide agent AMI 227. T1-weighted breath-hold gradient-echo images were obtained before and 45 min after i.v. administration of AMI 227. Signal intensity was measured in the aorta, the inferior vena cava, the portal vein, and muscle on unenhanced and contrast-enhanced images. Signal-to-noise ratios and enhancement [(SNR after contrast-SNR before contrast) / SNR before contrast] were calculated. Vessels were visually graded before and after administration of AMI 227. RESULTS: All vessels showed statistically significant enhancement 45 min. after administration of AMI 227 by both qualitative and quantitative measures (p < .001). There was no significant increase in noise or signal intensity of muscle after contrast material was administered. The amount of enhancement was not statistically significantly different among the three doses. CONCLUSIONS: AMI 227, which is currently in phase III clinical trials, demonstrates significant vascular enhancement and may prove useful as an MR angiographic contrast agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Li, W., Tutton, S., Vu, A. T., Pierchala, L., Li, B. S. Y., Lewis, J. M., Prasad, P. V., & Edelman, R. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20235 · Cited by 232
LaConte, L., Nitin, N., & Bao, G. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00893-x · Cited by 229
Hepatic MRI with SPIO: detection and characterization of focal liver lesions
Reimer, P., & Tombach, B. (1998) · European Radiology · doi:10.1007/s003300050535 · Cited by 187
Bjørnerud, A., & Johansson, L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.904 · Cited by 173
Blood Pool MR Angiography of Aortic Stent-Graft Endoleak
Ersoy, H., Jacobs, P., Kent, C. K., & Prince, M. R. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.5.1821181 · Cited by 119
Larsson, E.-M., Sundén, P., Olsson, C.-G., Debatin, J., Duerinckx, A. J., Baum, R., Hahn, D., & Ebner, F. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.1.1800227 · Cited by 29
“Intravascular contrast agents allow longer scanning times than extracellular contrast agents because of their relatively long half-life in the blood [16, 19].”
Background
Metadata
- Authors
- Mayo-Smith, W. W., Saini, S., Slater, G., Kaufman, J. A., Sharma, P., & Hahn, P. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1996-01
- Volume
- 166
- Issue
- 1
- Pages
- 73-77
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2142676833
- Cited by
- 91
- References
- 0
- FWCI
- 16.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.