Trends in Adverse Events After IV Administration of Contrast Media
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Data collected from 1985 to 1999 on adverse events after the IV administration of contrast media were evaluated to identify trends. MATERIALS AND METHODS: Data collected on 391 adverse events after 90,473 administrations of iodinated contrast media and 19 events after 28,340 administrations of gadolinium were evaluated. Reactions were graded as mild, moderate, or severe. Data were also collected regarding contrast extravasation. RESULTS: When only ionic iodinated contrast material was used, the adverse reaction rate was 6-8%. With the selective use of contrast material, the adverse reaction rate was 0.6% and 0.7%, respectively, for ionic and nonionic agents. The rate decreased to 0.2% with the universal use of nonionic agents. More than 90% of adverse reactions were allergic-like. Seven severe reactions (0.05%) and no deaths occurred in the ionic group. During the selective use period, one death occurred in the nonionic group. No severe reactions or deaths occurred during the first 5 years of universal nonionic use. Since then, 10 severe reactions (0.02%) and one death have occurred. Seven reactions occurred in patients after helical CT angiography. The extravasation rate for iodinated contrast material has remained constant at 0.3-0.4% annually. The adverse reaction rate to gadolinium contrast material was 0.06%. CONCLUSION: Mild and moderate adverse events are more common with ionic contrast material than with nonionic. Most reactions are allergic-like. Severe reactions are seen equally with ionic and nonionic contrast material but differ in type. The reactions were allergic-like in the ionic group but were predominantly attributable to cardiopulmonary decompensation in the nonionic group. Helical CT angiography may play a role in reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Katayama, H., Yamaguchi, K., Kozuka, T., Takashima, T., Seez, P., & Matsuura, K. (1990) · Radiology · doi:10.1148/radiology.175.3.2343107 · Cited by 1,474
Adverse reactions to gadolinium contrast media: a review of 36 cases.
Murphy, K. J., Brunberg, J. A., & Cohan, R. H. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.4.8819369 · Cited by 276
Cited by
Sidhu, P., Cantisani, V., Dietrich, C., Gilja, O., Saftoiu, A., Bartels, E., Bertolotto, M., Calliada, F., Clevert, D.-A., Cosgrove, D., et al. (2018) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0586-1107 · Cited by 1,086
Dietrich, C. F., Nolsøe, C. P., Barr, R. G., Berzigotti, A., Burns, P. N., Cantisani, V., Chammas, M. C., Chaubal, N., Choi, B. I., Clevert, D.-A., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.030 · Cited by 498
Microbubble-enhanced US in Body Imaging: What Role?
Wilson, S. R., & Burns, P. N. (2010) · Radiology · doi:10.1148/radiol.10091210 · Cited by 470
Epidemiology of life-threatening and lethal anaphylaxis: a review
Moneret‐Vautrin, D. A., Morisset, M., Flabbee, J., Beaudouin, E., & Kanny, G. (2005) · Allergy · doi:10.1111/j.1398-9995.2005.00785.x · Cited by 386
“(113) Protamine 1125 1 36% cases of anaphylaxis Cochrane and Bomyea (56) Iodine contrast agents >90 000 injections 0.”
BackgroundVerberne, H. J., Acampa, W., Anagnostopoulos, C., Ballinger, J., Bengel, F., De Bondt, P., Buechel, R. R., Cuocolo, A., van Eck-Smit, B. L. F., Flotats, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3139-x · Cited by 366
Safe Use of Contrast Media: What the Radiologist Needs to Know
Beckett, K. R., Moriarity, A. K., & Langer, J. M. (2015) · RadioGraphics · doi:10.1148/rg.2015150033 · Cited by 334
Dillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2554 · Cited by 303
“[19] during a 9year period in which this group observed an TABLE 2: Manifestations of Mild Acute Allergic-Like Reaction to Gadolinium-Containing Contrast Media (n = 40)”
BackgroundIodinated Contrast Media and Their Adverse Reactions
Singh, J., & Daftary, A. (2008) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.047621 · Cited by 293
Incidence of Nephrogenic Systemic Fibrosis at Two Large Medical Centers
Prince, M. R., Zhang, H., Morris, M., MacGregor, J. L., Grossman, M. E., Silberzweig, J., DeLapaz, R. L., Lee, H. J., Magro, C. M., & Valeri, A. M. (2008) · Radiology · doi:10.1148/radiol.2483071863 · Cited by 290
Ersoy, H., & Rybicki, F. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21135 · Cited by 283
Dietrich, C. F., Nolsøe, C. P., Barr, R. G., Berzigotti, A., Burns, P. N., Cantisani, V., Chammas, M. C., Chaubal, N., Choi, B. I., Clevert, D.-A., et al. (2020) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1177-0530 · Cited by 242
Toxicity of MRI and CT contrast agents
Hasebroock, K. M., & Serkova, N. J. (2009) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425250902873796 · Cited by 242
“The incidence of mild and moderate acute adverse reactions is higher for HOCM (4 – 12%) than for LOCM (1 – 3%) [35,38,48-50].”
BackgroundMortelé, K. J., Oliva, M.-R., Ondategui, S., Ros, P. R., & Silverman, S. G. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.1.01840031 · Cited by 209
“Urticaria and facial or laryngeal edema accounted for most (> 90%) of the adverse events [18].”
BackgroundResultInfluentialFluorescein angiography and adverse drug reactions revisited: the Lions Eye experience
Kwan, A. S., Barry, C., McAllister, I. L., & Constable, I. (2006) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2006.01136.x · Cited by 183
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
“In comparison with x-ray compounds, the number of such events is exceptionally low for MRI contrast agents.(21) Interestingly, patients with a history of adverse reaction to an iodinated contrast agent also are at a slightly greater risk of reacting to injection of a paramagnetic contrast agent.”
BackgroundCardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
Norton, K. I., Tong, C., Glass, R. B. J., & Nielsen, J. C. (2006) · RadioGraphics · doi:10.1148/rg.261055064 · Cited by 67
“No nephrotoxic contrast agents are used, and the prevalence of allergic and anaphylactoid reactions to gadolinium is significantly lower than that associated with the iodinated contrast material used for catheterization and CT (17).”
Metadata
- Authors
- Cochran, S. T., Bomyea, K., & Sayre, J. W.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-06
- Volume
- 176
- Issue
- 6
- Pages
- 1385-1388
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2132067973
- Cited by
- 358
- References
- 2
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.