The DOI matches its Crossref record; 76 of the 77 references it cites were found in a registry or an index.
Clearance Properties of Nano-Sized Particles and Molecules as Imaging Agents: Considerations and Caveats
Open accessAbstract
Nanoparticles possess enormous potential as diagnostic imaging agents and hold promise for the development of multimodality agents with both imaging and therapeutic capabilities. Yet, some of the most promising nanoparticles demonstrate prolonged tissue retention and contain heavy metals. This presents serious concerns for toxicity. The creation of nanoparticles with optimal clearance characteristics will minimize toxicity risks by reducing the duration of exposure to these agents. Given that many nanoparticles possess easily modifiable surface and interior chemistry, if nanoparticle characteristics associated with optimal clearance from the body were well established, it would be feasible to design and create agents with more favorable clearance properties. This article presents a thorough discussion of the physiologic aspects of nanoparticle clearance, focusing on renal mechanisms, and provides an overview of current research investigating clearance of specific types of nanoparticles and nano-sized macromolecules, including dendrimers, quantum dots, liposomes and carbon, gold and silica-based nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to the threshold for rapid renal excretion being about 5.5 nm, the hydrodynamic diameters of the prepared nanoparticles need to be larger than this size [168–170].”
From Non-viral delivery systems for CRISPR/Cas9-based genome editing: challenges and opportunities (2018) · cites this paper as [169]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
A Toxicologic Review of Quantum Dots: Toxicity Depends on Physicochemical and Environmental Factors
Hardman, R. C. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8284 · Cited by 2,304
Nanoengineering of optical resonances
Oldenburg, S. J., Averitt, R. D., Westcott, S. L., & Halas, N. J. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00277-2 · Cited by 2,266
Particle size-dependent organ distribution of gold nanoparticles after intravenous administration
de Jong, W. H., Hagens, W. I., Krystek, P., Burger, M. C., Sips, A. J. A. M., & Geertsma, R. E. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.037 · Cited by 1,620
Comparative Properties and Methods of Preparation of Lipid Vesicles (Liposomes)
Szoka, F. C., & Papahadjopoulos, D. (1980) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.09.060180.002343 · Cited by 1,515
Recent advances in iron oxide nanocrystal technology for medical imaging☆
Corot, C., Robert, P., Idée, J., & Port, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,461
Gold nanoparticles: a new X-ray contrast agent
Hainfeld, J. F., Slatkin, D. N., Focella, T. M., & Smilowitz, H. M. (2006) · British Journal of Radiology · doi:10.1259/bjr/13169882 · Cited by 1,351
Malik, N., Wiwattanapatapee, R., Klopsch, R., Lorenz, K., Frey, H., Weener, J.-W., Meijer, E. W., Paulus, W., & Duncan, R. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00246-1 · Cited by 1,228
Noninvasive Imaging of Quantum Dots in Mice
Ballou, B. T., Lagerholm, B. C., Ernst, L. A., Bruchez, M. P., & Waggoner, A. S. (2003) · Bioconjugate Chemistry · doi:10.1021/bc034153y · Cited by 1,141
Liu, Z., Davis, C. R., Cai, W., He, L., Chen, X.-Y., & Dai, H. (2008) · Proceedings of the National Academy of Sciences of the United States of America · doi:10.1073/pnas.0707654105 · Cited by 1,097
Research works printed but not linked: 2
- 10.1021/ja027555 · DOI
- Wisse E DoucetD Van Bossuyt H: A transmission electron microscopic study on the uptake of AMI-25 by sinusoidal liver cells. In: Cells of the Hepatic Sinusoid (Volume 3). Wisse E Knook DL McCuskey RS (Eds.). The Kupffer Cell Foundation Leiden The Netherlands 534–539 (1991).
Cited by
Sorted by citations
Principles of nanoparticle design for overcoming biological barriers to drug delivery
Blanco, E., Shen, H., & Ferrari, M. (2015) · Nature Biotechnology · doi:10.1038/nbt.3330 · Cited by 7,002
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El‐Sayed, M. A. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15237h · Cited by 3,659
Delivering nanomedicine to solid tumors
Jain, R. K., & Stylianopoulos, T. (2010) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2010.139 · Cited by 3,265
Mesoporous Silica Nanoparticles: Synthesis, Biocompatibility and Drug Delivery
Tang, F., Li, L., & Chen, D. (2012) · Advanced Materials · doi:10.1002/adma.201104763 · Cited by 2,898
Upconversion Nanoparticles: Design, Nanochemistry, and Applications in Theranostics
Chen, G., Qiu, H., Prasad, P. N., & Chen, X. S. (2014) · Chemical Reviews · doi:10.1021/cr400425h · Cited by 2,746
Metadata
- Authors
- Longmire, M., Choyke, P. L., & Kobayashi, H.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Kobayashi, Hisataka
- Venue
- Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2008-09-25
- Volume
- 3
- Issue
- 5
- Pages
- 703-717
- ISSN
- 1743-5889 (ISSN-L)
- 1748-6963
- PMC
- PMC3407669
- OpenAlex
- W2150146274
- Cited by
- 2,149
- References
- 77
- Citations by year
- 2026: 84 · 2025: 139 · 2024: 128 · 2023: 157 · 2022: 146 · 2021: 175 · 2020: 181 · 2019: 178 · 2018: 160 · 2017: 170 · 2016: 156 · 2015: 121 · 2014: 99 · 2013: 88 · 2012: 63
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Nanomedicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (Z99 CA999999)
- National Cancer Institute (ZIABC010657)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Materials Science › General Materials Science › Nanotechnology research and applications
- Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
- Keywords
- nanoparticle clearance, diagnostic imaging agents, renal clearance, nanoparticle toxicity, heavy metals, dendrimers, quantum dots, liposomes, carbon nanoparticles, gold nanoparticles, silica nanoparticles, tissue retention
- MeSH terms
- Biocompatible Materials, Diagnostic Imaging, Gold, Humans, Kidney, Liposomes, Liver, Magnetic Resonance Imaging, Particle Size, Polymers, Silicon Dioxide, Nanotubes, Carbon, Quantum Dots, Dendrimers, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review