Do implantable loop recorders impact the survival of patients with recurrent unexplained syncope?
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Aim: This study compares the outcomes of patients who receive an implantable loop recorder (ILR) for unexplained syncope to a control group without the diagnostic device in German claims data. Methods and materials: Patients with ILR were matched to a control group based on prior syncope events, age, gender and Charlson Comorbidity index (CCI). Survival, syncope hospitalizations, treatment and costs were compared. Results/conclusion: Four hundred and twelve ILR patients were matched with controls, mean age was 68, mean CCI was 2.7, 42% females. ILR patients lived on average 1.2 years longer than patients in the control group. Twenty-five percent of ILR patients received a therapeutic device compared with 5% in the control group. ILRs might help to diagnose and treat patients with positive impact on survival.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hence, the ILR provided a high diagnostic yield in terms of cardiac arrhythmias in patients with syncope, not restricted to arrhythmias directly related to syncope [12,13,14,15,17,19,35,36] but including other diagnoses with therapeutic implications such as atrial fibrillation.”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [19]
In the citing paper
“with a shorter time to diagnosis, more frequent treatment initiation, and a positive impact on survival compared to a conventional diagnostic workup [13,17,19].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [19]
Citations
Cites
Validation of a combined comorbidity index
Charlson, M., Szatrowski, T. P., Peterson, J., & Gold, J. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90129-5 · Cited by 6,587
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Incidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364
Thygesen, S. K., Christiansen, C. F., Christensen, S., Lash, T. L., & Sørensen, H. T. (2011) · BMC Medical Research Methodology · doi:10.1186/1471-2288-11-83 · Cited by 1,195
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,126
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 631
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.003 · Cited by 327
Impairment of physical and psychosocial function in recurrent syncope
Linzer, M., Pontinen, M., Gold, D. T., Divine, G. W., Felder, A., & Blair Brooks, W. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90005-t · Cited by 296
Edvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250
Priori, S. G., Blomström‐Lundqvist, C., Mazzanti, A., Blom, N. A., Borggrefe, M., Camm, A. J., Elliot, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · UCL Discovery (University College London) · Cited by 212
Survival in second degree atrioventricular block
Shaw, D. B., Kekwick, C. A., Veale, D., Gowers, J., & Whistance, T. (1985) · Heart · doi:10.1136/hrt.53.6.587 · Cited by 132
Castelnuovo, E., Stein, K., Pitt, M., Garside, R., & Payne, E. (2005) · Health Technology Assessment · doi:10.3310/hta9430 · Cited by 127
Clinical Factors Associated with Quality of Life in Patients with Transient Loss of Consciousness
VAN DIJK, N., SPRANGERS, M. A., COLMAN, N., BOER, K. R., WIELING, W., & LINZER, M. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00533.x · Cited by 125
Bartoletti, A., Fabiani, P., Bagnoli, L., Cappelletti, C., Cappellini, M., Nappini, G., Gianni, R., Lavacchi, A., & Santoro, G. M. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm563 · Cited by 102
Linzer, M., Gold, D. T., Pontinen, M., Divine, G., Felder, A., & Brooks, W. B. (1994) · Journal of General Internal Medicine · doi:10.1007/bf02600121 · Cited by 99
Quality-of-Life, Health Service Use, and Costs Associated With Syncope
Sun, B. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.10.009 · Cited by 97
Accuracy of the ICD-10 discharge diagnosis for syncope
Ruwald, M. H., Hansen, M. L., Lamberts, M., Kristensen, S. L., Wissenberg, M., Olsen, A.-M. S., Christensen, S. B., Vinther, M., Kober, L., Torp-Pedersen, C., et al. (2013) · Europace · doi:10.1093/europace/eus359 · Cited by 79
The effect of paediatric syncope on health-related quality of life
Anderson, J. B., Czosek, R. J., Knilans, T. K., & Marino, B. S. (2012) · Cardiology in the Young · doi:10.1017/s1047951112000133 · Cited by 57
Cardiovascular risk after hospitalisation for unexplained syncope and orthostatic hypotension
Yasa, E., Ricci, F., Magnusson, M., Sutton, R., Gallina, S., Caterina, R. D., Melander, O., & Fedorowski, A. (2017) · Heart · doi:10.1136/heartjnl-2017-311857 · Cited by 49
Atrioventricular block: Natural history after permanent ventricular pacing
Simon, A. B., & Zloto, A. E. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90006-1 · Cited by 44
NICE guideline: transient loss of consciousness (blackouts) in adults and young people
Rogers, G., & O'Flynn, N. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x548965 · Cited by 40
Prevalence and Morbidity of Heart Block in Devon
Shaw, D. B., & Eraut, D. (1970) · BMJ · doi:10.1136/bmj.1.5689.144 · Cited by 33
Edvardsson, N., Wolff, C., Tsintzos, S., Rieger, G., & Linker, N. J. (2015) · Europace · doi:10.1093/europace/euu412 · Cited by 29
Self-citationVitale, E., Ungar, A., Maggi, R., Francese, M., Lunati, M., Colaceci, R., Rosso, A. D., Castro, A., Santini, M., Giuli, S., et al. (2010) · EP Europace · doi:10.1093/europace/euq302 · Cited by 28
van Eck, J. W. M., van Hemel, N. M., Kelder, J. C., van den Bos, A. A., Taks, W., Grobbee, D. E., Moons, K. G. M., & on behalf of the FOLLOWPACE investigators (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01018.x · Cited by 23
Ricci, F., Sutton, R., Palermi, S., Tana, C., Renda, G., Gallina, S., Melander, O., Caterina, R. D., & Fedorowski, A. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13715 · Cited by 21
Numé, A., Kragholm, K. H., Carlson, N., Kristensen, S. L., Bøggild, H., Hlatky, M. A., Torp-Pedersen, C. T., Gislason, G., & Ruwald, M. H. (2017) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.116.003202 · Cited by 19
Research works printed but not linked: 1
- National Institute for Health and Care Excellence (NICE). Implantable cardioverter defibrillators and cardiac resynchronisation therapy for arrhythmias and heart failure. NICE Technology Appraisal Guidance 314 (2014).
Cited by
Quartieri, F., Manyam, H., Calò, L., Ebrahim, I. O., Fusco, A. M., Mester, S. W., Cauti, F. M., Park, S., Francia, P., Giovagnoni, M., et al. (2023) · EP Europace · doi:10.1093/europace/euad068 · Cited by 20
Duvillier, L., Demolder, A., Renterghem, S. V., Mey, C. D., West, F., & Pooter, J. D. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16420 · Cited by 5
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061564 · Cited by 4
“Formally, the ICD-10-GM code R55 includes syncope as well as collapse, which may have led to the inclusion of patients without actual syncope.”
BackgroundMethodInfluentialPorta‐Sánchez, A., Casado, R., Salvador, O., Sánchez‐Enrique, C., Bayona, S., Sanchez-Borque, P., Campal, J. M. R., & Cabrera, J. Á. (2021) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2021.10.011 · Cited by 3
Saha, S. A., Rosemas, S. C., Sarkar, S., Ramos, V., Radtke, A. P., Majumder, S., Melis, M. D., Zhou, J., & Sims, J. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.70214 · Cited by 3
“…therapy types (medical and procedural) are in line with or greater than prior studies of ICM patients — with a higher cumulative therapy rate — likely because our analysis allowed for the inclusion of all relevant therapies compared to previous studies with more targeted endpoints [5, 35, 37, 38].”
Metadata
- Authors
- Perings, C., Wolff, C., Wilk, A., Witthohn, A., Voss, R., & Rybak, K.
- Affiliations
- Katholisches Klinikum Lünen/Werne , St.-Marien-Hospital Lünen (DE)
- Medtronic (Switzerland) (CH)
- Team Gesundheit, Gesellschaft für Gesundheitsmanagement GmbH, Rellinghauser Str. 93, 45128 Essen, Germany
- Medtronic (Germany) (DE)
- Kardiologische Praxis, Kochstedter Kreisstraße 11, 06847 Dessau-Roßlau, Germany
- Corresponding author
- Wolff, Claudia
- Venue
- Journal of Comparative Effectiveness Research
- Publisher
- Becaris Publishing Limited
- Published
- 2021-03
- Volume
- 10
- Issue
- 4
- Pages
- 285-294
- ISSN
- 2042-6305 (ISSN-L)
- 2042-6313
- OpenAlex
- W3122480719
- Cited by
- 7
- References
- 32
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Comparative Effectiveness Research (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable loop recorder, unexplained syncope, recurrent syncope, survival, health care costs, cardiac implantable electronic devices, syncope diagnosis, claims data
- MeSH terms
- Aged, Electrodes, Implanted, Female, Humans, Male, Syncope
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.