The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Iron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia
Abstract
Many different nanostructures have been developed for biomedical applications to date. Among them, iron oxide nanoparticles have been very prominent in MRI in diagnostic radiology. Nowadays, nanoparticle-based therapeutic applications have gained increased interest, leading to the development of a great variety of different and, in parts, sophisticated nanoparticle formulations. Whereas nanotherapy has been confined to the preclinical phase, magnetic hyperthermia has entered into the clinical phase via controlled studies in patients. Owing to the versatility of nanoparticles, researchers envision the combination of multiple modalities (e.g., targeting, diagnostics and therapy) to one carrier. Nevertheless, such approaches have been challenging due to the necessity of the adaptation of at least partially counteracting parameters between the different modalities, which will be analyzed in this review.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer, vascular, rheumatoid and other disease
Folkman, J. (1995) · Nature Medicine · doi:10.1038/nm0195-27 · Cited by 7,627
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Immunological properties of engineered nanomaterials
Dobrovolskaia, M. A., & McNeil, S. E. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.223 · Cited by 1,823
de Vries, I. J. M., Lesterhuis, W. J., Barentsz, J. O., Verdijk, P., van Krieken, J. H., Boerman, O. C., Oyen, W. J. G., Bonenkamp, J. J., Boezeman, J. B., Adema, G. J., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1154 · Cited by 821
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Thermosensitive liposomes entrapping iron oxide nanoparticles for controllable drug release
Tai, L.-A., Tsai, P.-J., Wang, Y.-C., Wang, Y.-J., Lo, L.-W., & Yang, C.-S. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/13/135101 · Cited by 145
Cited by
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Magnetic Nanoparticles in Cancer Theranostics
Gobbo, O. L., Sjaastad, K., Radomski, M. W., Volkov, Y., & Prina-Mello, A. (2015) · Theranostics · doi:10.7150/thno.11544 · Cited by 462
Recent advances in metal nanoparticles in cancer therapy
Sharma, A., Goyal, A. K., & Rath, G. (2018) · Journal of Drug Targeting · doi:10.1080/1061186x.2017.1400553 · Cited by 341
Design of iron oxide-based nanoparticles for MRI and magnetic hyperthermia
Blanco-Andujar, C., Walter, A., Cotin, G., Bordeianu, C., Mertz, D., Felder-Flesch, D., & Begin-Colin, S. (2016) · Nanomedicine · doi:10.2217/nnm-2016-5001 · Cited by 276
Zhu, L., Zhou, Z., Mao, H., & Yang, L. (2017) · Nanomedicine · doi:10.2217/nnm-2016-0316 · Cited by 267
Metadata
- Authors
- Hilger, I., & Kaiser, W. A.
- Venue
- Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2012-09
- Volume
- 7
- Issue
- 9
- Pages
- 1443-1459
- ISSN
- 1743-5889 (ISSN-L)
- 1748-6963
- OpenAlex
- W2149352542
- Cited by
- 243
- References
- 6
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia. https://app.cochat.ai/papers/10.2217/nnm.12.112
- The paper
- Hilger, I., & Kaiser, W. A. (2012). Iron Oxide-Based Nanostructures for MRI and Magnetic Hyperthermia. Nanomedicine. https://doi.org/10.2217/nnm.12.112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.