CoChat

Error mitigation on a near-term quantum photonic device

Open access
Su, Daiqin, Israel, Robert, Sharma, Kunal, Qi, Haoyu, Dhand, Ish, Brádler, Kamil · 2021 · Quantum

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Abstract

Photon loss is destructive to the performance of quantum photonic devices and therefore suppressing the effects of photon loss is paramount to photonic quantum technologies. We present two schemes to mitigate the effects of photon loss for a Gaussian Boson Sampling device, in particular, to improve the estimation of the sampling probabilities. Instead of using error correction codes which are expensive in terms of their hardware resource overhead, our schemes require only a small amount of hardware modifications or even no modification. Our loss-suppression techniques rely either on collecting additional measurement data or on classical post-processing once the measurement data is obtained. We show that with a moderate cost of classical post processing, the effects of photon loss can be significantly suppressed for a certain amount of loss. The proposed schemes are thus a key enabler for applications of near-term photonic quantum devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.22331/q-2021-05-04-452

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Error mitigation to a lossy TMSV state with squeezing parameter r = 1 . 0 . The red circles represent probabilities for a pure TMSV state, the blue squares represent probabilities for a lossy TMSV state and the black rhombuses represent the extrapolated probabilities with photon loss ϵ = 0 . 1 .
Figure 1 Error mitigation to a lossy TMSV state with squeezing parameter r = 1 . 0 . The red circles represent probabilities for a pure TMSV state, the blue squares represent probabilities for a lossy TMSV state and the black rhombuses represent the extrapolated probabilities with photon loss ϵ = 0 . 1 .CC-BY · From the PDF
Figure 2 Distribution of extrapolated probability for click pattern [1 , 1] due to the uncertainty of probability measurement. Here 500 samples of size N = 10 5 are collected. The mean and standard deviation of the extrapolated probability are 0.2373 and 0.2531, respectively.
Figure 2 Distribution of extrapolated probability for click pattern [1 , 1] due to the uncertainty of probability measurement. Here 500 samples of size N = 10 5 are collected. The mean and standard deviation of the extrapolated probability are 0.2373 and 0.2531, respectively.CC-BY · From the PDF
Figure 3 Distribution of extrapolated probability for click pattern [1 , 1] due to the uncertainty of loss values. The fluctuation of the loss value is assumed to follow a normal distribution with standard deviation 0 . 01 . The total number of samples is 500, and the mean and standard deviation of the extrapolated probability is 0.2425 and 0.2873, respectively.
Figure 3 Distribution of extrapolated probability for click pattern [1 , 1] due to the uncertainty of loss values. The fluctuation of the loss value is assumed to follow a normal distribution with standard deviation 0 . 01 . The total number of samples is 500, and the mean and standard deviation of the extrapolated probability is 0.2425 and 0.2873, respectively.CC-BY · From the PDF
Figure 4 Procedure to cancel photon loss. In the first step, the probabilities of a lossy device are calculated using the probabilities of a loss-free device. This corresponds to a physical process and is accomplished by applying the operator T ϵ . In the second step, the probabilities of a loss-free device are inferred using the probabilities of a lossy device. This is accomplished by applying the operator T ⊖ ϵ but does not correspond to a physical process.
Figure 4 Procedure to cancel photon loss. In the first step, the probabilities of a lossy device are calculated using the probabilities of a loss-free device. This corresponds to a physical process and is accomplished by applying the operator T ϵ . In the second step, the probabilities of a loss-free device are inferred using the probabilities of a lossy device. This is accomplished by applying the operator T ⊖ ϵ but does not correspond to a physical process.CC-BY · From the PDF
Figure 5 Estimate orbit probabilities using extrapolation technique. In each subfigure there are four histograms, they represent the orbit probabilities without photon loss, with photon loss, with extrapolation and with the improved extrapolation, respectively. The loss values for (a), (b), (c) and (d) are ϵ = 0 . 1 , 0 . 2 , 0 . 3 and 0 . 4 , respectively.
Figure 5 Estimate orbit probabilities using extrapolation technique. In each subfigure there are four histograms, they represent the orbit probabilities without photon loss, with photon loss, with extrapolation and with the improved extrapolation, respectively. The loss values for (a), (b), (c) and (d) are ϵ = 0 . 1 , 0 . 2 , 0 . 3 and 0 . 4 , respectively.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Research works printed but not linked: 4

  1. [22] X. Bonet-Monroig, R. Sagastizabal, M. Singh, and T. E. O'Brien, Low-cost error mitigation by symmetry verification, Phys. Rev. A 98 , 062339 (2018). - · DOI · Paper page
  2. [26] M. Cerezo, K. Sharma, A. Arrasmith, and P. J. Coles, Variational quantum state eigensolver, arXiv:2004.01372. - · arXiv
  3. [31] M. R. Geller, and M. Sun, Efficient correction of multiqubit measurement errors, arXiv:2001.09980. - · arXiv
  4. [32] L. Funcke, T. Hartung, K. Jansen, S. Kühn, P. Stornati, and X. Wang, Measurement error mitigation in quantum computers through classical bit-flip correction, arXiv:2007.03663. - · arXiv

Cited by

See all 29

Metadata

Authors
Su, D., Israel, R., Sharma, K., Qi, H., Dhand, I., & Brádler, K.
Affiliations
  • Xanadu Quantum Technologies (Canada) (CA)
  • Louisiana State University (US)
Venue
Quantum
Published
2021-05-04
Volume
5
Pages
452
ISSN
2521-327X (ISSN-L)
OpenAlex
W3049230998
Cited by
19
References
46
Citations by year
2026: 3 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 6
FWCI
1.24
Type
journal article
Language
en
Open access
Locations
  • Quantum (publishedVersion, cc-by)
  • arXiv (Cornell University) (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University) (cc-by)
Funders
Engineering and Physical Sciences Research Council (EP/R045577/1)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Mechanics and Applications
Keywords
Gaussian boson sampling, classical post-processing, loss suppression, near-term quantum devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Error mitigation on a near-term quantum photonic device. https://app.cochat.ai/papers/10.22331/q-2021-05-04-452
The paper
Su, D., Israel, R., Sharma, K., Qi, H., Dhand, I., & Brádler, K. (2021). Error mitigation on a near-term quantum photonic device. Quantum. https://doi.org/10.22331/q-2021-05-04-452

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.