Measurement in Medicine: The Analysis of Method Comparison Studies
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
D. G. Altman, J. M. Bland, Measurement in Medicine: The Analysis of Method Comparison Studies, Journal of the Royal Statistical Society. Series D (The Statistician), Vol. 32, No. 3 (Sep., 1983), pp. 307-317
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, studies with high measurement noise or with low myelin variance (e.g. between subjects of the same group) may artificially deflate the true underlying correlation coefficient (Altman, Bland, 1983, Goodwin, Leech, 2006).”
From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Altman, Bland, 1983
In the citing paper
“We did not state in early publications that the LoA method assumes independent observations [Altman and Bland (1983) Bland and Altman (1986)], as this important requirement is not specific to the LoA approach but rather applies to all types of statistical analyses.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Altman and Bland (1983)
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“In 1983 Altman and Bland (B&A) proposed an alternative analysis, based on the quantification of the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
Citations
Cites
Biostatistics: A Foundation for Analysis in the Health Sciences.
Rosenfeld, B., & Daniel, W. W. (1984) · Journal of the American Statistical Association · doi:10.2307/2288760 · Cited by 2,834
Incorrect least-squares regression coefficients in method-comparison analysis.
Cornbleet, P. J., & Gochman, N. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.432 · Cited by 573
PITMAN, E. J. G. (1939) · Biometrika · doi:10.1093/biomet/31.1-2.9 · Cited by 480
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Measurement of left ventricular ejection fraction by mechanical cross-sectional echocardiography.
Carr, K. W., Engler, R. L., Forsythe, J. R., Johnson, A. D., & Gosink, B. (1979) · Circulation · doi:10.1161/01.cir.59.6.1196 · Cited by 153
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
A Multivariate Approach for the Biometrie Comparison of Analytical Methods in Clinical Chemistry
Feldmann, U., Schneider, B., Klinkers, H., & Haeckel, R. (1981) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1981.19.3.121 · Cited by 112
Principal component analysis. Alternative to referee methods in method comparison studies
Carey, R. N., Wold, S., & Westgard, J. O. (1975) · Analytical Chemistry · doi:10.1021/ac60361a037 · Cited by 72
Laughlin, K. D., Sherrard, D. J., & Fisher, L. D. (1980) · Journal of Chronic Diseases · doi:10.1016/0021-9681(80)90064-8 · Cited by 71
Impedance cardiography for determination of stroke index
Keim, H. J., Wallace, J. M., Thurston, H., Case, D. B., Drayer, J. I. M., & LARAGH, J. H. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.5.797 · Cited by 67
Cited by
Items 701–800 of 1,017
Knobelspiesse, K., Tan, Q., Bruegge, C. J., Cairns, B., Chowdhary, J., van Diedenhoven, B., Diner, D. J., Ferrare, R. A., van Harten, G., Jovanovic, V., et al. (2019) · Applied Optics · doi:10.1364/ao.58.000650 · Cited by 60
Nicolini, G., Aubinet, M., Feigenwinter, C., Heinesch, B., Lindroth, A., Mamadou, O., Moderow, U., Mölder, M., Montagnani, L., Rebmann, C., et al. (2017) · Agricultural and Forest Meteorology · doi:10.1016/j.agrformet.2017.09.025 · Cited by 60
Stolarczyk, L., Heyward, V., Van Loan, M., Hicks, V., Wilson, W., & Reano, L. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/66.1.8 · Cited by 59
Aalbers, T., Baars, M. A. E., Olde Rikkert, M. G. M., & Kessels, R. P. C. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2860 · Cited by 59
Disagreement in Patient and Carer Assessment of Functional Abilities After Stroke
Knapp, P., & Hewison, J. (1999) · Stroke · doi:10.1161/01.str.30.5.934 · Cited by 59
Schoenfeld, B. J., Nickerson, B. S., Wilborn, C. D., Urbina, S. L., Hayward, S. B., Krieger, J., Aragon, A. A., & Tinsley, G. M. (2020) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002708 · Cited by 59
Golley, R. K., Bell, L., Hendrie, G. A., Rangan, A., Spence, A. C., McNaughton, S. A., Carpenter, L. M., Allman-Farinelli, M. A., de Silva, A. M., Gill, T. P., et al. (2016) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12399 · Cited by 60
Prediction of reader estimates of mammographic density using convolutional neural networks
Ionescu, G. V., Fergie, M., Berks, M., Harkness, E. F., Hulleman, J., Brentnall, A. R., Cuzick, J. M., Evans, D. G., & Astley, S. (2019) · Journal of medical imaging · doi:10.1117/1.jmi.6.3.031405 · Cited by 59
Pillarisetti, A., Carter, E. M., Rajkumar, S., Young, B. N., Benka‐Coker, M. L., Peel, J. L., Johnson, M. A., & Clark, M. L. (2018) · Environment International · doi:10.1016/j.envint.2018.11.014 · Cited by 59
White, S. A., & van den Broek, N. R. (2004) · Statistics in Medicine · doi:10.1002/sim.1804 · Cited by 59
Measurement of skeletal muscle area: Comparison of CT and MR imaging
Sinelnikov, A., Qu, C., Fetzer, D. T., Pelletier, J., Dunn, M. A., Tsung, A., & Furlan, A. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.07.006 · Cited by 59
Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM2.5 Exposure Assessment
Borghi, F., Spinazzè, A., Campagnolo, D., Rovelli, S., Cattaneo, A., & Cavallo, D. M. (2018) · Sensors · doi:10.3390/s18093089 · Cited by 59
Sládek, V., Berner, M. E., Galeta, P., Friedl, L., & Kudrnová, Š. (2009) · American Journal of Physical Anthropology · doi:10.1002/ajpa.21153 · Cited by 59
Lampen-Sachar, K., Zhao, B., Zheng, J., Moskowitz, C. S., Schwartz, L. H., Zakowski, M. F., Rizvi, N. A., Kris, M. G., & Ginsberg, M. S. (2011) · Lung Cancer · doi:10.1016/j.lungcan.2011.08.001 · Cited by 59
Non-Invasive Detection of Respiration and Heart Rate with a Vehicle Seat Sensor
Wusk, G., & Gabler, H. C. (2018) · Sensors · doi:10.3390/s18051463 · Cited by 59
Accommodative Lag by Autorefraction and Two Dynamic Retinoscopy Methods
Correction of Myopia Evaluation Trial 2 Study Group for the Pediatric Eye Disease Investigator Group (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318197180c · Cited by 59
Spahn, G., Klinger, H.-M., Baums, M. H., Hoffmann, M., Plettenberg, H., Kroker, A., & Hofmann, G. O. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510376744 · Cited by 59
Protocol to measure acute cerebrovascular and ventilatory responses to isocapnic hypoxia in humans
Kolb, J. C., Ainslie, P. N., Ide, K., & Poulin, M. J. (2004) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2004.04.014 · Cited by 59
Effects of Background Noise on Click-Evoked Otoacoustic Emissions
Rhoades, K., McPherson, B., Smyth, V., Kei, J., & Baglioni, A. J. (1998) · Ear and Hearing · doi:10.1097/00003446-199812000-00006 · Cited by 59
Accuracy of 1-, 5- and 10-year body weight recall given in a standard questionnaire
Olivarius, N. D. F., Andreasen, A. H., & Løken, J. (1997) · International Journal of Obesity · doi:10.1038/sj.ijo.0800365 · Cited by 59
Limitations in Surrogate Measures of Insulin Resistance
Buchanan, T. A., Watanabe, R. M., & Xiang, A. H. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2167 · Cited by 58
Celis, N., Casallas, A., López-Barrera, E. A., Felician, M., Marchi, M. D., & Pappalardo, S. E. (2023) · ISPRS International Journal of Geo-Information · doi:10.3390/ijgi12100436 · Cited by 58
Validity and Reliability of Kinect v2 for Quantifying Upper Body Kinematics during Seated Reaching
Faity, G. V., Mottet, D., & Froger, J. (2022) · Sensors · doi:10.3390/s22072735 · Cited by 58
Accuracy and bias of methods used for root length measurements in functional root research
Delory, B. M., Weidlich, E. W. A., Meder, L., Lütje, A., van Duijnen, R., Weidlich, R., & Temperton, V. M. (2017) · Methods in Ecology and Evolution · doi:10.1111/2041-210x.12771 · Cited by 58
Chaobal, H., & Kharasch, E. D. (2005) · Clinical Pharmacology & Therapeutics · doi:10.1016/j.clpt.2005.08.004 · Cited by 58
Du, C., Li, B., Li, Y., Xu, M., & Yao, R. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106349 · Cited by 58
Leaf‐IT: An Android application for measuring leaf area
Schrader, J., Pillar, G., & Kreft, H. (2017) · Ecology and Evolution · doi:10.1002/ece3.3485 · Cited by 58
Tanguy, M., Boyeau, C., Pean, S., Marijon, É., Delhumeau, A., & Fanello, S. (2011) · Vaccine · doi:10.1016/j.vaccine.2011.03.107 · Cited by 58
In vivostudy of myocardial elastography under graded ischemia conditions
Lee, W.-N., Provost, J., Fujikura, K., Wang, J., & Konofagou, E. E. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/017 · Cited by 58
Development and Preliminary Evaluation of a Smartphone App for Measuring Eye Alignment
Pundlik, S. J., Tomasi, M., Liu, R., Houston, K., & Luo, G. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.1.19 · Cited by 58
Cook, J. D., Eftekari, S. C., Dallmann, E., Sippy, M., & Plante, D. T. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12789 · Cited by 57
Statistical Methods for the Validation of Questionnaires: Discrepancy between Theory and Practice
Schmidt, M. E., & Steindorf, K. (2006) · Methods of Information in Medicine · doi:10.1055/s-0038-1634096 · Cited by 57
Validation of Instrument Measuring Continuous Variable in Medicine
Zaki, R. A. (2017) · InTech eBooks · doi:10.5772/66151 · Cited by 57
Horowitz, G. S., Byles, J., Lee, J., & D’Este, C. A. (2004) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2004.00907.x · Cited by 57
Cattaneo, A., Peruzzo, C., Garramone, G., Urso, P., Ruggeri, R., Carrer, P., & Cavallo, D. M. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00731.x · Cited by 57
Myers, J., Gardiner, K., Harris, K., Lilien, T., Bennett, M., Chow, E., Selby, D., & Zhang, L. (2010) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2009.06.013 · Cited by 57
Dorsal and palmar aspect dimensions of hand anthropometry for designing hand tools and protections
Vergara, M., Torres, M. J. A., & Gracia-Ibáñez, V. (2017) · Human Factors and Ergonomics in Manufacturing & Service Industries · doi:10.1002/hfm.20714 · Cited by 57
Mid-arm circumference can be used to estimate children's weights
Cattermole, G. N., Leung, P. Y. M., Mak, P. S. K., Graham, C. A., & Rainer, T. H. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.05.015 · Cited by 57
van den Berg-Emons, R. J. G., van Baak, M. A., & Westerterp, K. R. (1998) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1998.tb15385.x · Cited by 57
Kimmerly, D. S., O'Leary, D. D., & Shoemaker, J. K. (2004) · Autonomic Neuroscience · doi:10.1016/j.autneu.2004.06.005 · Cited by 56
Development of Repeated Sprint Ability in Talented Youth Basketball Players
Wierike, S. C. M. T., de Jong, M. C., Tromp, E. J. Y., Vuijk, P. J., LEMMINK, K. A. P. M., Malina, R. M., Elferink-Gemser, M. T., & Visscher, C. (2014) · The Journal of Strength and Conditioning Research · doi:10.1097/jsc.0000000000000223 · Cited by 56
Moinpour, C. M., Lyons, B., Schmidt, S., Chansky, K., & Patchell, R. A. (2000) · Quality of Life Research · doi:10.1023/a:1008978512572 · Cited by 56
Reliability and validity of Canada???s Physical Activity Monitor for assessing trends
Craig, C. L., Russell, S. J., & Cameron, C. A. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00010 · Cited by 56
McLellan, G., Arthur, R., & Buchan, D. S. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1461322 · Cited by 56
Accuracy of telephone dietary recalls in elderly subjects
Dubois, S., & Boivin, J. (1990) · Journal of the American Dietetic Association · doi:10.1016/s0002-8223(21)01875-7 · Cited by 56
Barthez, P. Y., Hornof, W. J., Cowgill, L. D., Neal, L. A., & Mickel, P. (1998) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.1998.tb01636.x · Cited by 56
Data Normalization and Scaling: Consequences for the Analysis in Omics Sciences
Walach, J., Filzmoser, P., & Hron, K. (2018) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2018.06.004 · Cited by 56
Seymour, J., McNamee, P., Scott, A., & Tinelli, M. (2009) · Health Economics · doi:10.1002/hec.1505 · Cited by 56
Agarwal, A. K., & Sharma, R. K. (2006) · Fertility and Sterility · doi:10.1016/j.fertnstert.2006.05.083 · Cited by 56
Martin, G. P., Sperrin, M., Ludman, P., de Belder, M., Gale, C. P., Toff, W. D., Moat, N. E., Trivedi, U., Buchan, I. E., & Mamas, M. A. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.10.020 · Cited by 56
Pickett, B. R., & Buell, J. C. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)91235-v · Cited by 56
Comparison of methods of measuring blood pressure.
Altman, D. G., & Bland, J. M. (1986) · Journal of Epidemiology & Community Health · doi:10.1136/jech.40.3.274 · Cited by 56
Self-citationLange, A., Walayat, M., Turnbull, C. M., Palka, P., Mankad, P. S., Sutherland, G. R., & Godman, M. J. (1997) · Heart · doi:10.1136/hrt.78.4.382 · Cited by 56
Ten Years of Traffic Speed Deflectometer Research in the United States: A Review
Katicha, S. W., Flintsch, G. W., & Diefenderfer, B. K. (2022) · Transportation Research Record Journal of the Transportation Research Board · doi:10.1177/03611981221094579 · Cited by 56
Telemedicine in Prehospital Acute Stroke Care
Geisler, F., Kunz, A. B., Winter, B., Różański, M., Waldschmidt, C., Weber, J. E., Wendt, M., Zieschang, K., Ebinger, M., & Audebert, H. J. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.011729 · Cited by 56
Boelaert, M., Safi, S. E., Mousa, H., Mbati, J., Gurubacharya, V. L., Shrestha, J., JACQUET, D., Muynck, A. D., Ray, D. L., Boelaert, M., et al. (1999) · Tropical Medicine & International Health · doi:10.1046/j.1365-3156.1999.00348.x · Cited by 56
Modelling impacts of climate change on water resources in the Volta Basin, West Africa
Kasei, R. A. (2010) · bonndoc (University of Bonn) · Cited by 58
Rason, M. A., Randriantsoa, T., Andrianantenaina, H., Ratsimbasoa, A. C., & Ménard, D. (2008) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/j.trstmh.2008.01.021 · Cited by 56
Kampen, A. H., Tollersrud, T., & Lund, A. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.03.008 · Cited by 57
Жилич, С. В., Rudaya, N. A., Константинович, К. С., Nazarova, L., & Pozdnyakov, D. V. (2017) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2017.03.022 · Cited by 56
de Abreu, M. G., Quintel, M., Ragaller, M., & Albrecht, D. M. (1997) · Critical Care Medicine · doi:10.1097/00003246-199704000-00020 · Cited by 56
Latikka, P., Battié, M. C., Videman, T., & Gibbons, L. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(94)00003-p · Cited by 55
Runcie, C. J., Reeve, W., Reidy, J., & Dougall, J. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14393.x · Cited by 55
de Larrea-Mancera, E. S. L., Stavropoulos, T., Hoover, E. C., Eddins, D. A., Gallun, F. J., & Seitz, A. R. (2020) · The Journal of the Acoustical Society of America · doi:10.1121/10.0002108 · Cited by 55
Validity of the SenseWear® Armband to Predict Energy Expenditure in Pregnant Women
SMITH, K. M., LANNINGHAM-FOSTER, L. M., WELK, G. J., & CAMPBELL, C. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31825ce76f · Cited by 55
Viability of gait speed test in hospitalized elderly patients
Martinez, B. P., Batista, A. K. M. S., Ramos, Í. R., Dantas, J. C. N., Gomes, I. B., Forgiarini, L. A., Camelier, F. W. R., & Camelier, A. A. (2016) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37562015000000058 · Cited by 56
Heart rate monitoring to assess energy expenditure in children with reduced physical activity
VAN DEN BERG-EMONS, R. J. G., SARIS, W. H. M., WESTERTERP, K. R., & VAN BAAK, M. A. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199604000-00015 · Cited by 55
Clinical review: Brain-body temperature differences in adults with severe traumatic brain injury
Childs, C., & Kueh, W. L. (2013) · Critical Care · doi:10.1186/cc11892 · Cited by 55
BA-plotteR – A web tool for generating Bland-Altman plots and constructing limits of agreement
Goedhart, J., & Rishniw, M. (2021) · Research in Veterinary Science · doi:10.1016/j.rvsc.2021.05.017 · Cited by 55
Assessing Agreement between Methods of Measurement
Altman, D. G., & Bland, M. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.268870 · Cited by 55
Self-citationCarkeet, A., & Goh, Y. T. (2016) · Statistical Methods in Medical Research · doi:10.1177/0962280216665419 · Cited by 55
Yao, P., Xue, N., Yin, S., You, C., Guo, Y., Shi, Y., Liu, T., Yao, L., Zhou, J., Sun, J., et al. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3167059 · Cited by 56
Repeatability and validity of Zywave aberrometer measurements
Hament, W. J., Nabar, V. A., & Nuijts, R. M. M. A. (2002) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(02)01333-0 · Cited by 55
Schweizer, D. W., Cisneros, R., & Shaw, G. D. (2016) · Atmospheric Pollution Research · doi:10.1016/j.apr.2016.02.003 · Cited by 55
Griffin, J. M., Lall, R., Bruce, J., Withers, E. J., Finnegan, S., Lamb, S. E., Lamb, S. E., Underwood, M. R., Martin, F. C., Yardley, L., et al. (2018) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2018.09.006 · Cited by 55
Magbity, E., Lines, J., Marbiah, M. T., David, K., & Peterson, E. (2002) · Bulletin of Entomological Research · doi:10.1079/ber2001131 · Cited by 55
Nosir, Y. F. M., Vletter, W. B., Boersma, E. H., Frowijn, R., ten Cate, F. J., Fioretti, P. M., & Roelandt, J. R. T. C. (1997) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a015414 · Cited by 55
Francq, B., & Govaerts, B. B. (2016) · Statistics in Medicine · doi:10.1002/sim.6872 · Cited by 54
On detecting interference from endogenous antibodies in immunoassays by doubling dilutions test
Ismail, A. A. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.152 · Cited by 54
Cook, J. D., Prairie, M. L., & Plante, D. T. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7120 · Cited by 54
Keikhosravi, A., Li, B., Liu, Y., Conklin, M. W., Loeffler, A. G., & Eliceiri, K. W. (2020) · Communications Biology · doi:10.1038/s42003-020-01151-5 · Cited by 54
Analysis of the Ear Pulse Oximeter Waveform
Alian, A. A., Stout, R. G., Ghobashy, M. A. M., Rezkanna, H., Silverman, D. G., & Shelley, K. H. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9018-z · Cited by 54
Smith, K. C., Washington, C., Brown, J. L., Vadnais, A., Kroart, L., Ferguson, J. M., & Cohen, J. E. (2015) · JMIR Public Health and Surveillance · doi:10.2196/publichealth.4616 · Cited by 55
Assessment of handheld mobile terrestrial laser scanning for estimating tree parameters
Stal, C., Verbeurgt, J., Sloover, L. D., & Wulf, A. D. (2020) · Journal of Forestry Research · doi:10.1007/s11676-020-01214-7 · Cited by 54
RNA polymerase II at histone genes predicts outcome in human cancer
Henikoff, S., Zheng, Y., Paranal, R. M., Xu, Y., Greene, J. E., Henikoff, J. G., Russell, Z. R., Szulzewsky, F., Thirimanne, H. N., Kugel, S., et al. (2025) · Science · doi:10.1126/science.ads2169 · Cited by 54
ASSESSING TEST-RETEST RELIABILITY OF THE PORTABLE BROWER SPEED TRAP II TESTING SYSTEM
Shalfawi, S. A. I., Enoksen, E., Tønnessen, E., & Ingebrigtsen, J. (2012) · Kinesiology · Cited by 58
Effect of cycloplegia on axial length and anterior chamber depth measurements in children
Cheung, S. W., Chan, R., Cheng, R., & Cho, P. (2009) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2009.00419.x · Cited by 54
Kohnen, T., Terzi, E., Kasper, T., Kohnen, E.-M., & Bühren, J. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.05.009 · Cited by 54
Quantitative MRI of kidneys in renal disease
Kline, T. L., Edwards, M. E., Garg, I., Irazabal, M. V., Korfiatis, P. D., Harris, P. C., King, B. F., Torres, V. E., Venkatesh, S. K., & Erickson, B. J. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1236-y · Cited by 54
Point-of-care blood analyzers measure the nutritional state of eighteen free-living bird species
Morales, A. C., Frei, B., Leung, C., Titman, R. D., Whelan, S., Benowitz‐Fredericks, Z. M., & Elliott, K. H. (2019) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2019.110594 · Cited by 54
Evaluation of spleen stiffness in healthy volunteers using point shear wave elastography
Giuffrè, M., Macor, D., Masutti, F., Abazia, C., Tinè, F., Patti, R., Buonocore, M. R., Colombo, A. A., Visintin, A., Campigotto, M., et al. (2019) · Annals of Hepatology · doi:10.1016/j.aohep.2019.03.004 · Cited by 54
Siangproh, W., Teshima, N., Sakai, T., Katoh, S., & Chailapakul, O. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.068 · Cited by 54
Measurement of Functional Residual Capacity in Rabbits and Children Using an Ultrasonic Flow Meter
Schibler, A., & Henning, R. H. (2001) · Pediatric Research · doi:10.1203/00006450-200104000-00022 · Cited by 54
Doering, L. V., Lum, E., Dracup, K., & Friedman, A. (1995) · Critical Care Medicine · doi:10.1097/00003246-199510000-00010 · Cited by 54
Mellor, K., Eddy, S., Peckham, N., Bond, C. M., Campbell, M. J., Lancaster, G., Thabane, L., Eldridge, S. M., Dutton, S., & Hopewell, S. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048178 · Cited by 53
Analysis of repeatability in spotted cDNA microarrays
Jenssen, T.-K. (2002) · Nucleic Acids Research · doi:10.1093/nar/gkf441 · Cited by 53
Kindt, S., Coulie, B., Wajs, E., Janssens, J., & Tack, J. (2008) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2008.01092.x · Cited by 53
Tammemägi, M. C., Frank, J. W., LeBlanc, M. L., Artsob, H., & Streiner, D. L. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00243-j · Cited by 53
Validity of instruments to assess students' travel and pedestrian safety
Mendoza, J. A., Watson, K., Baranowski, T., Nicklas, T. A., Uscanga, D. K., & Hanfling, M. J. (2010) · BMC Public Health · doi:10.1186/1471-2458-10-257 · Cited by 53
Patterns of adherence to antiretroviral medications: the value of electronic monitoring
McNabb, J. J., Nicolau, D. P., Stoner, J. A., & Ross, J. (2003) · AIDS · doi:10.1097/00002030-200308150-00005 · Cited by 53
Metadata
- Authors
- Altman, D. G., & Bland, J. M.
- Affiliations
- Medical Research Council (GB)
- St George's, University of London (GB)
- Venue
- The Statistician
- Publisher
- JSTOR
- Published
- 1983-09
- Volume
- 32
- Issue
- 3
- Pages
- 307
- ISSN
- 0039-0526 (ISSN-L)
- OpenAlex
- W2133750711
- Semantic Scholar
- 029929987c1321e6880234bf0492689a7a379e38
- Cited by
- 4,300
- References
- 19
- Citations by year
- 2026: 73 · 2025: 158 · 2024: 221 · 2023: 230 · 2022: 238 · 2021: 239 · 2020: 245 · 2019: 207 · 2018: 186 · 2017: 174 · 2016: 173 · 2015: 145 · 2014: 165 · 2013: 145 · 2012: 151
- FWCI
- 25.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Royal Statistical Society Series D (The Statistician) (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- method comparison, measurement error, measurement agreement, regression analysis, bias and precision, diagnostic accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.