Measurement in Medicine: The Analysis of Method Comparison Studies
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
D. G. Altman, J. M. Bland, Measurement in Medicine: The Analysis of Method Comparison Studies, Journal of the Royal Statistical Society. Series D (The Statistician), Vol. 32, No. 3 (Sep., 1983), pp. 307-317
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, studies with high measurement noise or with low myelin variance (e.g. between subjects of the same group) may artificially deflate the true underlying correlation coefficient (Altman, Bland, 1983, Goodwin, Leech, 2006).”
From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Altman, Bland, 1983
In the citing paper
“We did not state in early publications that the LoA method assumes independent observations [Altman and Bland (1983) Bland and Altman (1986)], as this important requirement is not specific to the LoA approach but rather applies to all types of statistical analyses.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Altman and Bland (1983)
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“In 1983 Altman and Bland (B&A) proposed an alternative analysis, based on the quantification of the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
Citations
Cites
Biostatistics: A Foundation for Analysis in the Health Sciences.
Rosenfeld, B., & Daniel, W. W. (1984) · Journal of the American Statistical Association · doi:10.2307/2288760 · Cited by 2,834
Incorrect least-squares regression coefficients in method-comparison analysis.
Cornbleet, P. J., & Gochman, N. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.432 · Cited by 573
PITMAN, E. J. G. (1939) · Biometrika · doi:10.1093/biomet/31.1-2.9 · Cited by 480
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Measurement of left ventricular ejection fraction by mechanical cross-sectional echocardiography.
Carr, K. W., Engler, R. L., Forsythe, J. R., Johnson, A. D., & Gosink, B. (1979) · Circulation · doi:10.1161/01.cir.59.6.1196 · Cited by 153
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
A Multivariate Approach for the Biometrie Comparison of Analytical Methods in Clinical Chemistry
Feldmann, U., Schneider, B., Klinkers, H., & Haeckel, R. (1981) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1981.19.3.121 · Cited by 112
Principal component analysis. Alternative to referee methods in method comparison studies
Carey, R. N., Wold, S., & Westgard, J. O. (1975) · Analytical Chemistry · doi:10.1021/ac60361a037 · Cited by 72
Laughlin, K. D., Sherrard, D. J., & Fisher, L. D. (1980) · Journal of Chronic Diseases · doi:10.1016/0021-9681(80)90064-8 · Cited by 71
Impedance cardiography for determination of stroke index
Keim, H. J., Wallace, J. M., Thurston, H., Case, D. B., Drayer, J. I. M., & LARAGH, J. H. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.5.797 · Cited by 67
Cited by
Items 1,001–1,017 of 1,017
Ma, D., Holmes, H. E., Cardoso, M. J., Modat, M., Harrison, I. F., Powell, N. M., O’Callaghan, J. M., Ismail, O., Johnson, R. A., O’Neill, M. J., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00011 · Cited by 36
Lee, Q. Y., Redmond, S. J., Chan, G. S., Middleton, P. M., Steel, E., Malouf, P., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-19 · Cited by 34
“Agreement between the methods in this study was calculated using the bias and precision plot method described by Bland and Altman [20,22-24].”
MethodInfluentialFENICI, R., NENONEN, J., PESOLA, K., KORHONEN, P., LÖTJÖNEN, J., MÄKIJÄRVI, M., TOIVONEN, L., POUTANEN, V., KETO, P., & KATILA, T. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00602.x · Cited by 29
Burrows, T., Harries, S., Williams, R., Lum, C., & Callister, R. (2016) · Nutrients · doi:10.3390/nu8090548 · Cited by 28
Koestner, D., Stramski, D., & Reynolds, R. A. (2020) · Applied Optics · doi:10.1364/ao.396709 · Cited by 24
Prairie, M. W., Frisbie, S. H., Rao, K. K., Saksri, A. H., Parbat, S., & Mitchell, E. J. (2020) · PLOS ONE · doi:10.1371/journal.pone.0226761 · Cited by 24
“Bland-Altman plots for pair-wise comparisons of LED spectrophotometer #1 with 3 commercial spectrophotometers (Hach DR-2700, Hach 2010, Thermal Electron Spectronic 20D+) for Fe and Mn, as well as for LED spectrophotometer #1 with Agilent Technologies Cary 60 UV-Vis for F are presented in Figs 16–22 [50].”
MethodFENICI, R., PESOLA, K., KORHONEN, P., MÄKIJÄRVI, M., NENONEN, J., TOIVONEN, L., FENICI, P., & KATILA, T. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01207.x · Cited by 22
Predictive accuracy of bioimpedance in estimating fat-free mass of African-American women
AINSWORTH, B. E., STOLARCZYK, L. M., HEYWARD, V. H., BERRY, C. B., IRWIN, M. L., & MUSSULMAN, L. M. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199706000-00008 · Cited by 18
Proper use of noncontact infrared thermometry for temperature screening during COVID-19
Hussain, A. S., Hussain, H. S., Betcher, N., Behm, R., & Cagir, B. (2021) · Scientific Reports · doi:10.1038/s41598-021-90100-1 · Cited by 16
Evaluating a new wearable lactate threshold sensor in recreational to highly trained cyclists
Driller, M., Borges, N., & Plews, D. (2016) · Sports Engineering · doi:10.1007/s12283-016-0198-6 · Cited by 15
Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates
Rao, A., Eskandar-Afshari, F., Weiner, Y., Billman, E., McMillin, A., Sella, N., Roxlo, T., Liu, J., Leong, W., Helfenbein, E., et al. (2023) · Sensors · doi:10.3390/s23073690 · Cited by 14
“Bland–Altman analysis [15] for the mean difference between predicted BP (SBP, DBP, and MAP) and A-line BP demonstrates that SBP, DBP, and MAP predictions are within the FDA specifications when the sensor data |Q| > 2.”
BackgroundEvaluation of stroke volume estimation during orthostatic stress: the utility of Modelflow
Lucci, V.-E. M., Parsons, I. T., Hockin, B. C. D., & Claydon, V. E. (2023) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000671 · Cited by 12
“Echocardiography-derived estimates of SV were compared to Modelflow-derived estimates of SV using Bland-Altman analyses [19].”
MethodWang, Y., Peng, W., Tang, J., Dong, L., Gu, C., Zhang, X., Zhou, J., & Jia, W. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020705 · Cited by 11
A Validation Study of a Noninvasive Lactate Threshold Device
McMorries, R. M., Joubert, D. P., Jones, E. J., & Faries, M. D. (2019) · International Journal of Exercise Science · doi:10.70252/loed6863 · Cited by 14
Sendra-Pérez, C., Encarnación-Martínez, A., Oficial-Casado, F., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1457 · Cited by 9
Bombail, V., Brown, S. M., Beyts, C., Martin, J. E., Li, T., Meddle, S. L., Mendl, M., Robinson, E. S., Hammond, T. J., Nielsen, B. L., et al. (2025) · F1000Research · doi:10.12688/f1000research.166417.2 · Cited by 3
Safety, Efficiency, and Cost Conflicts in Emergency Department Point of Care Troponin Testing
Grabinski, Z., Swartz, J. L., Wang, Y., Itani, A., Aguero-Rosenfeld, M., Sanchez, N., Gulati, R., Wittman, I. G., & Smith, S. W. (2026) · Quality Management in Health Care · doi:10.1097/qmh.0000000000000502
Metadata
- Authors
- Altman, D. G., & Bland, J. M.
- Affiliations
- Medical Research Council (GB)
- St George's, University of London (GB)
- Venue
- The Statistician
- Publisher
- JSTOR
- Published
- 1983-09
- Volume
- 32
- Issue
- 3
- Pages
- 307
- ISSN
- 0039-0526 (ISSN-L)
- OpenAlex
- W2133750711
- Semantic Scholar
- 029929987c1321e6880234bf0492689a7a379e38
- Cited by
- 4,300
- References
- 19
- Citations by year
- 2026: 73 · 2025: 158 · 2024: 221 · 2023: 230 · 2022: 238 · 2021: 239 · 2020: 245 · 2019: 207 · 2018: 186 · 2017: 174 · 2016: 173 · 2015: 145 · 2014: 165 · 2013: 145 · 2012: 151
- FWCI
- 25.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Royal Statistical Society Series D (The Statistician) (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- method comparison, measurement error, measurement agreement, regression analysis, bias and precision, diagnostic accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.