Measurement in Medicine: The Analysis of Method Comparison Studies
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
D. G. Altman, J. M. Bland, Measurement in Medicine: The Analysis of Method Comparison Studies, Journal of the Royal Statistical Society. Series D (The Statistician), Vol. 32, No. 3 (Sep., 1983), pp. 307-317
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, studies with high measurement noise or with low myelin variance (e.g. between subjects of the same group) may artificially deflate the true underlying correlation coefficient (Altman, Bland, 1983, Goodwin, Leech, 2006).”
From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Altman, Bland, 1983
In the citing paper
“We did not state in early publications that the LoA method assumes independent observations [Altman and Bland (1983) Bland and Altman (1986)], as this important requirement is not specific to the LoA approach but rather applies to all types of statistical analyses.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Altman and Bland (1983)
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“In 1983 Altman and Bland (B&A) proposed an alternative analysis, based on the quantification of the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
Citations
Cites
Biostatistics: A Foundation for Analysis in the Health Sciences.
Rosenfeld, B., & Daniel, W. W. (1984) · Journal of the American Statistical Association · doi:10.2307/2288760 · Cited by 2,834
Incorrect least-squares regression coefficients in method-comparison analysis.
Cornbleet, P. J., & Gochman, N. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.432 · Cited by 573
PITMAN, E. J. G. (1939) · Biometrika · doi:10.1093/biomet/31.1-2.9 · Cited by 480
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Measurement of left ventricular ejection fraction by mechanical cross-sectional echocardiography.
Carr, K. W., Engler, R. L., Forsythe, J. R., Johnson, A. D., & Gosink, B. (1979) · Circulation · doi:10.1161/01.cir.59.6.1196 · Cited by 153
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
A Multivariate Approach for the Biometrie Comparison of Analytical Methods in Clinical Chemistry
Feldmann, U., Schneider, B., Klinkers, H., & Haeckel, R. (1981) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1981.19.3.121 · Cited by 112
Principal component analysis. Alternative to referee methods in method comparison studies
Carey, R. N., Wold, S., & Westgard, J. O. (1975) · Analytical Chemistry · doi:10.1021/ac60361a037 · Cited by 72
Laughlin, K. D., Sherrard, D. J., & Fisher, L. D. (1980) · Journal of Chronic Diseases · doi:10.1016/0021-9681(80)90064-8 · Cited by 71
Impedance cardiography for determination of stroke index
Keim, H. J., Wallace, J. M., Thurston, H., Case, D. B., Drayer, J. I. M., & LARAGH, J. H. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.5.797 · Cited by 67
Cited by
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Self-citationMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Self-citationMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Self-citationStatistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
“However, this high correlation does not mean that the two methods agree: (1) r measures the strength of a relation between two variables, not the agreement between them.”
BackgroundSelf-citationUnderstanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706
Statistics corner: A guide to appropriate use of correlation coefficient in medical research.
(2012) · Europe PMC (PubMed Central) · Cited by 4,239
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Self-citationAgreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Self-citationDiagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Development, validation and utilisation of food-frequency questionnaires – a review
Cade, J., Thompson, R., Burley, V., & Warm, D. (2002) · Public Health Nutrition · doi:10.1079/phn2001318 · Cited by 1,423
Fernandes, A. D., Reid, J. N., Macklaim, J. M., McMurrough, T. A., Edgell, D. R., & Gloor, G. B. (2014) · Microbiome · doi:10.1186/2049-2618-2-15 · Cited by 1,329
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Self-citationMedicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
A standardized method for measuring intracranial arterial stenosis.
Samuels, O. B., Joseph, G., Lynn, M., Smith, H. A., & Chimowitz, M. I. (2000) · PubMed Central · Cited by 1,107
Standardized challenge testing with pharmacological, physical and sensitizing stimuli in adults
Sterk, P. J., Fabbri, L. M., Quanjer, P. H., Cockcroft, D. W., O'Byrne, P. M., Anderson, S. D., Juniper, E. F., & Malo, J.-L. (1993) · European Respiratory Journal · doi:10.1183/09041950.053s1693 · Cited by 1,049
Statistical methods for assessing observer variability in clinical measures.
Brennan, P., & Silman, A. (1992) · BMJ · doi:10.1136/bmj.304.6840.1491 · Cited by 985
Bartlett, J. W., & Frost, C. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5256 · Cited by 936
Birks, H. J. B., & Birks, H. J. B. (1998) · Journal of Paleolimnology · doi:10.1023/a:1008038808690 · Cited by 885
ANOVA-Like Differential Expression (ALDEx) Analysis for Mixed Population RNA-Seq
Fernandes, A. D., Macklaim, J. M., Linn, T. G., Reid, G., & Gloor, G. B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067019 · Cited by 876
Conway, J. M., Ingwersen, L. A., Vinyard, B. T., & Moshfegh, A. J. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.5.1171 · Cited by 820
Measurement of Ventricular Torsion by Two-Dimensional Ultrasound Speckle Tracking Imaging
Notomi, Y., Shiota, T., Popović, Z. B., Weaver, J. A., Oryszak, S. J., Greenberg, N. L., White, R. D., Thomas, J. D., Setser, R. M., White, R. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.02.082 · Cited by 767
A critical discussion of intraclass correlation coefficients
Müller, R., & Büttner, P. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132310 · Cited by 714
Bland, J. M., & Altman, D. G. (1990) · Computers in Biology and Medicine · doi:10.1016/0010-4825(90)90013-f · Cited by 691
Self-citationBurton, P., Gurrin, L., & Sly, P. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980615)17:11<1261::aid-sim846>3.0.co;2-z · Cited by 635
Use of actigraphy for assessment in pediatric sleep research
Meltzer, L. J., Montgomery-Downs, H. E., Insana, S. P., & Walsh, C. M. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.10.002 · Cited by 628
The Trunk Impairment Scale: a new tool to measure motor impairment of the trunk after stroke
Verheyden, G., Nieuwboer, A., Mertin, J., Preger, R., Kiekens, C., & De Weerdt, W. (2004) · Clinical Rehabilitation · doi:10.1191/0269215504cr733oa · Cited by 550
Conway, J. M., Ingwersen, L. A., & Moshfegh, A. J. (2004) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2004.01.007 · Cited by 546
Psychometric adequacy of the Tinnitus Handicap Inventory (THI) for evaluating treatment outcome.
Newman, C. W., Sandridge, S. A., & Jacobson, G. P. (1998) · PubMed · Cited by 553
The Repeatability of Clinical Measurements of Dry Eye
Nichols, K. K., Mitchell, G. L., & Zadnik, K. (2004) · Cornea · doi:10.1097/00003226-200404000-00010 · Cited by 493
Warner, B. B., Deych, E., Zhou, Y., Hall-Moore, C., Weinstock, G. M., Sodergren, E., Shaikh, N., Hoffmann, J. A., Linneman, L. A., Hamvas, A., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00081-7 · Cited by 474
Gmel, G., & Rehm, J. (2004) · Contemporary Drug Problems · doi:10.1177/009145090403100304 · Cited by 466
Statistical Techniques For Comparing Measurers And Methods Of Measurement: A Critical Review
Ludbrook, J. (2002) · Clinical and Experimental Pharmacology and Physiology · doi:10.1046/j.1440-1681.2002.03686.x · Cited by 455
Refractive Error and Ethnicity in Children
Kleinstein, R. N. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.8.1141 · Cited by 448
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436
“Altman and Bland recognised the limitations of using correlation coefficients in the clinical comparison of two measurement methods.(10) Specifically, their landmark paper deals with the ‘limits of agreement’ between two methods, for example, comparing a new method to an old one.”
MethodLi, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Schüssler-Fiorenza Rose, S. M., Perelman, D., Colbert, E., Runge, R., Rego, S., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2001402 · Cited by 431
Validity of (ultra-)short recordings for heart rate variability measurements.
Munoz, M. L., van Roon, A., Riese, H., Thio, C., Oostenbroek, E., Westrik, I., de Geus, E. J. C., Gansevoort, R., Lefrandt, J., Nolte, I. M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138921 · Cited by 423
Multimodal Assessment of the Aortic Annulus Diameter
Messika-Zeitoun, D., Serfaty, J.-M., Brochet, E., Ducrocq, G., Lepage, L., Detaint, D., Hyafil, F., Himbert, D., Pasi, N., Laissy, J.-P., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.063 · Cited by 422
Why Bland–Altman plots should use X, not (Y+X)/2 when X is a reference method
Krouwer, J. S. (2008) · Statistics in Medicine · doi:10.1002/sim.3086 · Cited by 415
Evaluation of wireless determination of skin temperature using iButtons
VANMARKENLICHTENBELT, W., DAANEN, H., WOUTERS, L., FRONCZEK, R., RAYMANN, R., SEVERENS, N., & VANSOMEREN, E. (2006) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.04.026 · Cited by 392
Accuracy of Self‐Reported Height and Weight in Women: An Integrative Review of the Literature
Engstrom, J. L., Paterson, S. A., Doherty, A., Trabulsi, M., & Speer, K. L. (2003) · Journal of Midwifery & Women's Health · doi:10.1016/s1526-9523(03)00281-2 · Cited by 392
New bioimpedance analysis system: improved phenotyping with whole-body analysis
Pietrobelli, A., Rubiano, F., St-Onge, M.-P., & Heymsfield, S. B. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601993 · Cited by 379
The repeatability of measurement of the ocular components.
Zadnik, K., Mutti, D. O., & Adams, A. J. (1992) · PubMed · Cited by 373
R2* magnetic resonance imaging of the liver in patients with iron overload
Hankins, J. S., McCarville, M. B., Loeffler, R. B., Smeltzer, M. P., Onciu, M., Hoffer, F. A., Li, C.-S., Wang, W. C., Ware, R. E., & Hillenbrand, C. M. (2009) · Blood · doi:10.1182/blood-2008-12-191643 · Cited by 372
Hawton, A., Green, C., Dickens, A. P., Richards, S. H., Taylor, R. S., Edwards, R., Greaves, C. J., & Campbell, J. L. (2011) · Quality of Life Research · doi:10.1007/s11136-010-9717-2 · Cited by 367
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 366
SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT
Ludbrook, J. (1997) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1997.tb01807.x · Cited by 363
Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise
JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126805.32659.43 · Cited by 362
Dewitte, K., Fierens, C., Stöckl, D., & Thienpont, L. M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.799 · Cited by 359
Slater, R., Cornelissen, L., Fabrizi, L., Patten, D., Yoxen, J., Worley, A., Boyd, S., Meek, J., & Fitzgerald, M. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61303-7 · Cited by 355
Reliability of health-related physical fitness tests in European adolescents. The HELENA Study
on behalf of the HELENA Study Group, Ortega, F. B., Artero, E. G., Ruiz, J. R., Vicente-Rodriguez, G., Bergman, P., Hagströmer, M., Ottevaere, C., Nagy, E., Konsta, O., et al. (2008) · International Journal of Obesity · doi:10.1038/ijo.2008.183 · Cited by 346
Derivation and internal validation of an equation for albumin-adjusted calcium
James, M. T., Zhang, J., Lyon, A. W., & Hemmelgarn, B. R. (2008) · BMC Clinical Pathology · doi:10.1186/1472-6890-8-12 · Cited by 343
Method comparison in the clinical laboratory
Jensen, A. L., & Kjelgaard‐Hansen, M. (2006) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2006.tb00131.x · Cited by 341
Validation of the Oxford WebQ Online 24-Hour Dietary Questionnaire Using Biomarkers
Greenwood, D. C., Hardie, L. J., Frost, G. S., Alwan, N. A., Bradbury, K. E., Carter, M., Elliott, P., Evans, C. E. L., Ford, H. E., Hancock, N., et al. (2019) · American Journal of Epidemiology · doi:10.1093/aje/kwz165 · Cited by 336
Chong, C. F., Adi, M. I. W., Thien, A., Suyoi, A., Mackie, A. J. A., Tin, A. S., Tripathi, S., Jaman, N. H., Tan, K., Kok, K. Y. Y., et al. (2010) · PubMed · Cited by 335
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R. (2005) · Circulation · doi:10.1161/circulationaha.105.554006 · Cited by 331
Determination of the transcript profile of human endometrium
Borthwick, J. M. (2003) · Molecular Human Reproduction · doi:10.1093/molehr/gag004 · Cited by 318
Sander, A. P., Hajer, N. M., Hemenway, K., & Miller, A. C. (2002) · Physical Therapy · doi:10.1093/ptj/82.12.1201 · Cited by 317
Nevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317
Colles, S. L., Dixon, J. B., Marks, P., Strauss, B. J., & O’Brien, P. E. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.2.304 · Cited by 317
Heat pain thresholds: normative data and repeatability
Yarnitsky, D., Sprecher, E., Zaslansky, R., & Hemli, J. A. (1995) · Pain · doi:10.1016/0304-3959(94)00132-x · Cited by 313
Evaluation of the Lactate Pro blood lactate analyser
Pyne, D. B., Boston, T., Martin, D. T., & Logan, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050659 · Cited by 313
Thermal testing: normative data and repeatability for various test algorithms
Yarnitsky, D., & Sprecher, E. (1994) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(94)90239-9 · Cited by 308
Design, Analysis, and Interpretation of Method-Comparison Studies
Hanneman, S. K. (2008) · AACN Advanced Critical Care · doi:10.1097/01.aacn.0000318125.41512.a3 · Cited by 306
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
“Repeated measures analysis of variance and the Bland–Altman concordance technique [10] were calculated to compare devices with PSG and with each other.”
MethodValidation of new clinical quantitative analysis software applicable in spine orthopaedic studies
Champain, S., Benchikh, K., Nogier, A., Mazel, C., Guise, J. D., & Skalli, W. (2006) · European Spine Journal · doi:10.1007/s00586-005-0927-1 · Cited by 297
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296
Zaki, R., Bulgiba, A., Ismail, R., & Ismail, N. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037908 · Cited by 293
Yuan, C., Beach, K. W., Smith, L. H., & Hatsukami, T. S. (1998) · Circulation · doi:10.1161/01.cir.98.24.2666 · Cited by 289
Broglio, S. P., & Puetz, T. W. (2008) · Sports Medicine · doi:10.2165/00007256-200838010-00005 · Cited by 288
Bioimpedance analysis: evaluation of leg-to-leg system based on pressure contact foot-pad electrodes
NU??EZ, C., GALLAGHER, D., VISSER, M., PI-SUNYER, F. X., WANG, Z., & HEYMSFIELD, S. B. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199704000-00015 · Cited by 281
Xu, G., Rowley, H. A., Wu, G., Alsop, D. C., Shankaranarayanan, A., Dowling, M., Christian, B. T., Oakes, T. R., & Johnson, S. C. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1462 · Cited by 280
All‐digital image capture and whole‐field analysis of ciliary beat frequency
Sisson, J. H., Stoner, J. A., Ammons, B. A., & Wyatt, T. A. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01209.x · Cited by 280
Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
Tanner, R. K., Fuller, K. L., & Ross, M. L. R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1379-9 · Cited by 274
Test-retest reliability of trunk accelerometry during standing and walking
Moe-Nilssen, R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90231-3 · Cited by 271
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01488.x · Cited by 269
Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R., & Foss, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200003000-00018 · Cited by 266
Lewis, G. F., Furman, S. A., McCool, M. F., & Porges, S. W. (2012) · Biological Psychology · doi:10.1016/j.biopsycho.2011.11.009 · Cited by 264
Gutin, B., Litaker, M., Islam, S., Manos, T., Smith, C., & Treiber, F. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/63.3.287 · Cited by 264
The Role of Anatomic Factors in Nutritional Autonomy After Extensive Small Bowel Resection
Carbonnel, F., Cosnes, J., Chevret, S., Beaugerie, L., Ngô, Y., Malafosse, M., Parc, R., Le Quintrec, Y., & Gendre, J. P. (1996) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607196020004275 · Cited by 264
Quantitative diffusion imaging in breast cancer: A clinical prospective study
Rubesova, E., Grell, A.-S., Maertelaer, V. D., Metens, T., Chao, S., & Lemort, M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20643 · Cited by 259
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Maddison, R., Ni Mhurchu, C., Jiang, Y., Vander Hoorn, S., Rodgers, A., Lawes, C. M., & Rush, E. (2007) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-4-62 · Cited by 255
Agreed Statistics: Measurement Method Comparison
Bland, J. M., Altman, D. G., & Warner, D. S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31823d7784 · Cited by 252
Self-citationCorrelation, Agreement, and Bland–Altman Analysis: Statistical Analysis of Method Comparison Studies
Bunce, C. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.09.032 · Cited by 250
A Critical Review of Ultra-Short-Term Heart Rate Variability Norms Research
Shaffer, F., Meehan, Z. M., & Zerr, C. L. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.594880 · Cited by 248
“Such logic would imply that having greater measurement error would be more favorable because it decreases the probability of finding a significant difference (Altman and Bland, 1983).”
BackgroundMethodResultInfluentialMuir, S. W., Luciak-Corea, C., & Beaupré, L. A. (2010) · Europe PMC (PubMed Central) · Cited by 248
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Ruuska, S., Hämäläinen, W., Kajava, S., Mughal, M., Matilainen, P., & Mononen, J. (2018) · Behavioural Processes · doi:10.1016/j.beproc.2018.01.004 · Cited by 246
“In medical science, there has been a long debate on appropriate validation methods for medical devices (e.g., Altman and Bland, 1983; Ludbrook, 2002; Zaki et al., 2012; Indrayan, 2013) and nearly all methods have been criticized.”
BackgroundMethodLines, J. D., Curtis, C. F., Wilkes, T. J., & Njunwa, K. J. (1991) · Bulletin of Entomological Research · doi:10.1017/s0007485300053268 · Cited by 245
Hammoud, M. A., Ligon, B. L., Elsouki, R., Shi, W. M., Schomer, D. F., & Sawaya, R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.5.0737 · Cited by 245
CT measurement of main pulmonary artery diameter.
Edwards, P. D., Bull, R. K., & Coulden, R. A. (1998) · British Journal of Radiology · doi:10.1259/bjr.71.850.10211060 · Cited by 239
Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study
Barker, S. J., Curry, J., Redford, D., & Morgan, S. (2006) · Anesthesiology · doi:10.1097/00000542-200611000-00008 · Cited by 238
“Bias (mean error) and precision (SD of error) were calculated as recommended by Altman and Bland.7 Linear regression was used to calculate the slope and intercept of the best fit straight line relation between the two methods.”
MethodPhillips, S. M., Banerjea, A., Feakins, R., Li, S. R., Bustin, S. A., & Dorudi, S. (2004) · British Journal of Surgery · doi:10.1002/bjs.4472 · Cited by 237
A Study of the Diagnostic Accuracy and Reliability of the Scoliometer and Adamʼs Forward Bend Test
Côté, P., Kreitz, B. G., Cassidy, J. D., Dzus, A. K., & Martel, J. (1998) · Spine · doi:10.1097/00007632-199804010-00011 · Cited by 236
A Deep Learning Approach for Weed Detection in Lettuce Crops Using Multispectral Images
Osorio, K., Puerto, A., Pedraza, C., Jamaica, D., & Rodríguez, L. (2020) · AgriEngineering · doi:10.3390/agriengineering2030032 · Cited by 236
“Therefore, two methods can have a good correlation but not agreement, or vice versa [48].”
MethodNotomi, Y., Setser, R. M., Shiota, T., Martin-Miklovic, M. G., Weaver, J. A., Popović, Z. B., Yamada, H., Greenberg, N. L., White, R. D., & Thomas, J. D. (2005) · Circulation · doi:10.1161/01.cir.0000157151.10971.98 · Cited by 235
(1999) · PubMed · Cited by 230
Prevalence of bronchial reactivity to inhaled methacholine in New Zealand children.
Sears, M. R., Jones, D. T., Holdaway, M. D., Hewitt, C. J., Flannery, E. M., Herbison, G. P., & Silva, P. A. (1986) · Thorax · doi:10.1136/thx.41.4.283 · Cited by 230
Meltzer, L. J., Hiruma, L. S., Avis, K., Montgomery-Downs, H., & Valentin, J. (2015) · Sleep · doi:10.5665/sleep.4918 · Cited by 228
Metadata
- Authors
- Altman, D. G., & Bland, J. M.
- Affiliations
- Medical Research Council (GB)
- St George's, University of London (GB)
- Venue
- The Statistician
- Publisher
- JSTOR
- Published
- 1983-09
- Volume
- 32
- Issue
- 3
- Pages
- 307
- ISSN
- 0039-0526 (ISSN-L)
- OpenAlex
- W2133750711
- Semantic Scholar
- 029929987c1321e6880234bf0492689a7a379e38
- Cited by
- 4,300
- References
- 19
- Citations by year
- 2026: 73 · 2025: 158 · 2024: 221 · 2023: 230 · 2022: 238 · 2021: 239 · 2020: 245 · 2019: 207 · 2018: 186 · 2017: 174 · 2016: 173 · 2015: 145 · 2014: 165 · 2013: 145 · 2012: 151
- FWCI
- 25.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Royal Statistical Society Series D (The Statistician) (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- method comparison, measurement error, measurement agreement, regression analysis, bias and precision, diagnostic accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.