Measurement in Medicine: The Analysis of Method Comparison Studies
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
D. G. Altman, J. M. Bland, Measurement in Medicine: The Analysis of Method Comparison Studies, Journal of the Royal Statistical Society. Series D (The Statistician), Vol. 32, No. 3 (Sep., 1983), pp. 307-317
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, studies with high measurement noise or with low myelin variance (e.g. between subjects of the same group) may artificially deflate the true underlying correlation coefficient (Altman, Bland, 1983, Goodwin, Leech, 2006).”
From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Altman, Bland, 1983
In the citing paper
“We did not state in early publications that the LoA method assumes independent observations [Altman and Bland (1983) Bland and Altman (1986)], as this important requirement is not specific to the LoA approach but rather applies to all types of statistical analyses.”
From Agreement Between Methods of Measurement with Multiple Observations Per Individual (2007) · cites this paper as Altman and Bland (1983)
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“The B&A plot analysis is a simple way to evaluate a bias between the mean differences, and to estimate an agreement interval, within which 95% of the differences of the second method, compared to the first one, fall.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
In the citing paper
“In 1983 Altman and Bland (B&A) proposed an alternative analysis, based on the quantification of the agreement between two quantitative measurements by studying the mean difference and constructing limits of agreement.”
From Understanding bland altman analysis (2015) · cites this paper as [2]
Citations
Cites
Biostatistics: A Foundation for Analysis in the Health Sciences.
Rosenfeld, B., & Daniel, W. W. (1984) · Journal of the American Statistical Association · doi:10.2307/2288760 · Cited by 2,834
Incorrect least-squares regression coefficients in method-comparison analysis.
Cornbleet, P. J., & Gochman, N. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.432 · Cited by 573
PITMAN, E. J. G. (1939) · Biometrika · doi:10.1093/biomet/31.1-2.9 · Cited by 480
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Measurement of left ventricular ejection fraction by mechanical cross-sectional echocardiography.
Carr, K. W., Engler, R. L., Forsythe, J. R., Johnson, A. D., & Gosink, B. (1979) · Circulation · doi:10.1161/01.cir.59.6.1196 · Cited by 153
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
A Multivariate Approach for the Biometrie Comparison of Analytical Methods in Clinical Chemistry
Feldmann, U., Schneider, B., Klinkers, H., & Haeckel, R. (1981) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1981.19.3.121 · Cited by 112
Principal component analysis. Alternative to referee methods in method comparison studies
Carey, R. N., Wold, S., & Westgard, J. O. (1975) · Analytical Chemistry · doi:10.1021/ac60361a037 · Cited by 72
Laughlin, K. D., Sherrard, D. J., & Fisher, L. D. (1980) · Journal of Chronic Diseases · doi:10.1016/0021-9681(80)90064-8 · Cited by 71
Impedance cardiography for determination of stroke index
Keim, H. J., Wallace, J. M., Thurston, H., Case, D. B., Drayer, J. I. M., & LARAGH, J. H. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.5.797 · Cited by 67
Cited by
Items 201–300 of 1,017
Eom, H., Lee, D., Han, S., Hariyani, Y. S., Lim, Y., Sohn, I., Park, K., & Park, C. (2020) · Sensors · doi:10.3390/s20082338 · Cited by 153
van Rooyen, H., Barnabas, R. V., Baeten, J. M., Phakathi, Z., Joseph, P., Krows, M. L., Hong, T., Murnane, P. M., Hughes, J. P., & Celum, C. (2013) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31829b567d · Cited by 153
Haghayegh, S., Kang, H.-A., Khoshnevis, S., Smolensky, M. H., & Diller, K. R. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab86d6 · Cited by 152
Kanerva, M., Poussa, T. A., & Pitkäranta, A. (2006) · Otolaryngology · doi:10.1016/j.otohns.2006.05.748 · Cited by 152
Gimeno-Santos, E., Raste, Y., Demeyer, H., Louvaris, Z., de Jong, C., Rabinovich, R. A., Hopkinson, N. S., Polkey, M. I., Vogiatzis, I., Tabberer, M., et al. (2015) · European Respiratory Journal · doi:10.1183/09031936.00183014 · Cited by 151
Ismail, A. A., Walker, P. L., Barth, J. H., Lewandowski, K. C., Jones, R., & Burr, W. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.2023 · Cited by 151
Andrews, P. J. D., Dearden, N. M., & Miller, J. D. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/67.5.553 · Cited by 151
Inter-observer reliability of ten tests used for predicting difficult tracheal intubation
Karkouti, K., Rose, D., Ferris, L. E., Wigglesworth, D. F., Meisami-Fard, T., & Lee, H. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011765 · Cited by 150
Duque, A., & RAKIC, P. T. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.3092-11.2011 · Cited by 150
Brantom, P., Bruner, L. H., Chamberlain, M. P., de Silva, O., Dupuis, J., Earl, L. K., Lovell, D. P., Pape, W. J. W., Uttley, M., Bagley, D. M., et al. (1997) · Toxicology in Vitro · doi:10.1016/s0887-2333(96)00069-0 · Cited by 150
Evaluating neurological outcome measures: the bare essentials.
Hobart, J. C., Lamping, D. L., & Thompson, A. J. (1996) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.60.2.127 · Cited by 149
Self-Reported Losses Versus Actual Losses in Online Gambling: An Empirical Study
Auer, M., & Griffiths, M. D. (2016) · Journal of Gambling Studies · doi:10.1007/s10899-016-9648-0 · Cited by 149
Critical review of near-infrared spectroscopic methods validations in pharmaceutical applications
Bleye, C. D., Chavez, P.-F., Mantanus, J., Marini, R. D., Hubert, P., Rozet, E., & Ziémons, E. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.02.003 · Cited by 148
Pelvic floor muscle contraction during a cough and decreased vesical neck mobility
Miller, J. (2001) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(00)01132-7 · Cited by 147
Gardner, A. S., Martin, J. C., Martin, D. T., Barras, M., & Jenkins, D. G. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0498-4 · Cited by 147
Wark, P. A., Hardie, L. J., Frost, G. S., Alwan, N. A., Carter, M. C., Elliott, P., Ford, H. E., Hancock, N., Morris, M. A., Mulla, U. Z., et al. (2018) · BMC Medicine · doi:10.1186/s12916-018-1113-8 · Cited by 150
Lumbar Lordosis and Pelvic Inclination in Adults With Chronic Low Back Pain
Youdas, J. W., Garrett, T. R., Egan, K. S., & Therneau, T. M. (2000) · Physical Therapy · doi:10.1093/ptj/80.3.261 · Cited by 146
Hefti, A. F. (1997) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411970080030601 · Cited by 147
Lupșor‐Platon, M., Badea, R., Ştefănescu, H., Grigorescu, M. D., Sparchez, Z. A., Serban, A., Branda, H., Iancu, S., & Maniu, A. (2008) · PubMed · Cited by 146
Blonna, D., Giani, A., Bellato, E., Mattei, L., Calò, M., Rossi, R., & Castoldi, F. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2015.11.059 · Cited by 146
Wang, X., Theodore, M. J., Mair, R., Trujillo-Lopez, E., du Plessis, M., Wolter, N., Baughman, A. L., Hatcher, C., Vuong, J., Lott, L., et al. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.06087-11 · Cited by 145
Sahuquillo, J., Poca, M. A., Arribas, M., Garnacho, A., & Rubio, E. (1999) · Journal of neurosurgery · doi:10.3171/jns.1999.90.1.0016 · Cited by 146
Dai, F., & Lu, M. (2010) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0000114 · Cited by 145
Measures of agreement: A single procedure
Bartko, J. J. (1994) · Statistics in Medicine · doi:10.1002/sim.4780130534 · Cited by 144
Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142
“The measurements performed by the smart textile were compared with the ones made by the OEP by using Bland Altman method [26].”
MethodCoste, J., Fermanian, J., & Venot, A. (1995) · Statistics in Medicine · doi:10.1002/sim.4780140402 · Cited by 142
Journal De La Société Française De Statistique
Caussinus, H., & de Falguerolles, A. (2005) · Wiley eBooks · doi:10.1002/0471667196.ess7017 · Cited by 141
Menghini, L., Cellini, N., Goldstone, A., Baker, F. C., & de Zambotti, M. (2021) · Sleep · doi:10.1093/sleep/zsaa170 · Cited by 141
A Novel Ultrasound Methodology for Estimating Spine Mineral Density
Conversano, F., Franchini, R., Greco, A., Soloperto, G., Chiriacò, F., Casciaro, E., Aventaggiato, M., Renna, M. D., Pisani, P., Paola, M. D., et al. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.08.017 · Cited by 140
The effect of cycloplegia on measurement of the ocular components.
Mutti, D. O., Zadnik, K., EGASHIRA, S. M., Kish, L., Twelker, J. D., & Adams, A. J. (1994) · PubMed · Cited by 140
Chertow, G. M., Lazarus, J. M., Lew, N. L., Ma, L., & Lowrie, E. G. (1997) · Kidney International · doi:10.1038/ki.1997.216 · Cited by 138
Early refractive development in humans
Saunders, K. J. (1995) · Survey of Ophthalmology · doi:10.1016/s0039-6257(95)80027-1 · Cited by 138
Puetz, T. W., MORLEY, C. A., & Herring, M. P. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.836 · Cited by 137
Validez y confiabilidad del cuestionario del ENASEM para la depresión en adultos mayores
Aguilar-Navarro, S. G., Fuentes-Cantú, A., Ávila‐Funes, J. A., & García-Mayo, E. J. (2007) · Salud Pública de México · doi:10.1590/s0036-36342007000400005 · Cited by 137
In Vivo Analysis of Ciliary Muscle Morphologic Changes with Accommodation and Axial Ametropia
Sheppard, A. L., & Davies, L. N. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5787 · Cited by 136
Prediction of body fat in 12-y-old African American and white children: evaluation of methods,,
Bray, G. A., DeLany, J. P., Vólaufová, J., Harsha, D. W., & Champagne, C. M. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.5.980 · Cited by 135
Li, Y., Sperrin, M., Ashcroft, D. M., & van Staa, T. P. (2020) · BMJ · doi:10.1136/bmj.m3919 · Cited by 135
A new tent trap for sampling exophagic and endophagic members of the Anopheles gambiae complex
Govella, N. J., Chaki, P., Geissbühler, Y., Kannady, K., Okumu, F. O., Charlwood, J. D., Anderson, R. A., & Killeen, G. F. (2009) · Malaria Journal · doi:10.1186/1475-2875-8-157 · Cited by 135
Lindner, E., & Pendley, B. D. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.11.022 · Cited by 135
Transcranial Doppler Pulsatility Index: Not an Accurate Method to Assess Intracranial Pressure
Behrens, A., Lenfeldt, N., Ambarki, K., Malm, J., Eklund, A., & Koskinen, L. (2010) · Neurosurgery · doi:10.1227/01.neu.0000369519.35932.f2 · Cited by 135
Defining Relapse of Ulcerative Colitis Using a Symptom-based Activity Index
Jowett, S. L., Jowett, S. L., Jowett, S. L., Jowett, S. L., Jowett, S. L., & Jowett, S. L. (2003) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365520310000654 · Cited by 134
Umair, M., Chalabianloo, N., Sas, C., & Ersoy, C. (2021) · IEEE Access · doi:10.1109/access.2021.3052131 · Cited by 135
Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures
CLOUD, G. C., Rajkumar, C., Kooner, J. S., COOKE, J., & Bulpitt, C. J. (2003) · Clinical Science · doi:10.1042/cs20030012 · Cited by 134
Smith, C., & Anderson, S. D. (1990) · European Respiratory Journal · doi:10.1183/09031936.93.03020144 · Cited by 134
Meijide, A., Manca, G., Goded, I., Magliulo, V., Tommasi, P. D., Seufert, G., & Cescatti, A. (2011) · Biogeosciences · doi:10.5194/bg-8-3809-2011 · Cited by 134
Iglesias, J. E., Schleicher, R. L., Laguna, S., Billot, B., Schaefer, P. W., McKaig, B. N., Goldstein, J. N., Sheth, K. N., Rosen, M. S., & Kimberly, W. T. (2022) · Radiology · doi:10.1148/radiol.220522 · Cited by 133
Brouwer, S., Kuijer, W., Dijkstra, P., Göeken, L., Groothoff, J., & Geertzen, J. (2004) · Disability and Rehabilitation · doi:10.1080/09638280310001639713 · Cited by 133
Validity of the energy-restricted Mediterranean Diet Adherence Screener
Schröder, H., Zomeño, M. D., Martínez-González, M. A., Salas-Salvadó, J., Corella, D., Vioque, J., Romaguera, D., Martínez, J. A., Tinahones, F. J., Miranda, J. L., et al. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.06.030 · Cited by 133
Validation of 3D Ultrasound Vessel Wall Volume: An Imaging Phenotype of Carotid Atherosclerosis
Egger, M., Spence, J. D., Fenster, A., & Párraga, G. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.01.013 · Cited by 133
Detecting and adjusting for small‐study effects in meta‐analysis
Rücker, G., Carpenter, J. R., & Schwarzer, G. (2011) · Biometrical Journal · doi:10.1002/bimj.201000151 · Cited by 132
“Figure 5 (top left panel) shows a scatterplot of b̂0 against b̂limðr2 ¼ 0:9006Þ: Bland–Altman plots (not shown; Altman and Bland, 1983) give no hints of systematic trends in the difference.”
BackgroundBias and Precision of Pulse Oximeters and Arterial Oximeters
Nickerson, B. G., Sarkisian, C. A., & Tremper, K. K. (1988) · CHEST Journal · doi:10.1378/chest.93.3.515 · Cited by 132
An Evaluation of Parameters for the Detection of Subclinical Rumen Acidosis in Dairy Herds
Enemark, J. M. D., Jørgensen, R. J., & Kristensen, N. B. (2004) · Veterinary Research Communications · doi:10.1023/b:verc.0000045949.31499.20 · Cited by 132
Santagostino, A., Garbaccio, G., Pistorio, A., Bolis, V., Camisasca, G., Pagliaro, P., & Girotto, M. (1999) · PubMed · Cited by 132
Metsavaht, L. F., Leporace, G., Riberto, M., Spósito, M. M. D. M., & Batista, L. A. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510365314 · Cited by 131
Mo, S., Krawitz, B. D., Efstathiadis, E., Geyman, L. S., Weitz, R., Chui, T. Y. P., Carroll, J., Dubra, A., & Rosen, R. B. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18932 · Cited by 131
Espinoza, K., Martínez, D. L. V., Torres, J. A., López, A., & Molina-Aiz, F. D. (2016) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2016.07.008 · Cited by 130
Kirby, J. S., Thorlacius, L., Villumsen, B., Ingram, J. R., Garg, A., Christensen, K. B., Butt, M., Esmann, S., Tan, J. K. L., & Jemec, G. B. E. (2019) · British Journal of Dermatology · doi:10.1111/bjd.18692 · Cited by 130
Robust Remote Heart Rate Estimation from Face Utilizing Spatial-temporal Attention
Niu, X., Zhao, X., Han, H., Das, A., Dantcheva, A., Shan, S., & Chen, X. (2019) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2019.8756554 · Cited by 131
Massaroni, C., Lopes, D. S., Presti, D. L., Schena, E., & Silvestri, S. (2018) · Journal of Sensors · doi:10.1155/2018/4567213 · Cited by 130
Van Marken Lichtenbelt, W. D., Westerterp, K. R., & Wouters, L. (1994) · British Journal of Nutrition · doi:10.1079/bjn19940053 · Cited by 128
Aortic compliance measurements using doppler ultrasound: In vivo biochemical correlates
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90087-5 · Cited by 129
Robot-aided assessment of lower extremity functions: a review
Maggioni, S., Melendez-Calderon, A., van Asseldonk, E. H. F., Klamroth-Marganska, V., Lünenburger, L., Riener, R., & van der Kooij, H. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0180-3 · Cited by 128
Bezodis, N. E., Salo, A., & Trewartha, G. (2010) · Sports Biomechanics · doi:10.1080/14763141.2010.538713 · Cited by 128
What does the Phenol Red Thread Test Actually Measure?
Tomlinson, A., Blades, K., & Pearce, E. I. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb01226.x · Cited by 128
Methacholine bronchial challenge using a dosimeter with controlled tidal breathing.
Nieminen, M. M., Lahdensuo, A., KELLOMÄKI, L., Karvonen, J., & MUITTARI, A. (1988) · Thorax · doi:10.1136/thx.43.11.896 · Cited by 127
Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis
Gennaro, G., Bernardi, D., & Houssami, N. (2017) · European Radiology · doi:10.1007/s00330-017-5024-4 · Cited by 127
An Optical Fibre-Based Sensor for Respiratory Monitoring
Krehel, M., Schmid, M., Rossi, R., Boesel, L., Bona, G.-L., & Scherer, L. (2014) · Sensors · doi:10.3390/s140713088 · Cited by 127
Derwig, I. E., Lythgoe, D. J., Barker, G. J., Poon, L. C., Gowland, P. A., Yeung, R., Zelaya, F. O., & Nicolaides, K. H. (2013) · Placenta · doi:10.1016/j.placenta.2013.07.006 · Cited by 127
Díez‐Pérez, A., Brandi, M. L., Al‐Daghri, N. M., Branco, J., Bruyère, O., Cavalli, L., Cooper, C. C., Cortet, B., Dawson-Hughes, B. F., Dimai, H. P., et al. (2019) · Aging Clinical and Experimental Research · doi:10.1007/s40520-019-01294-4 · Cited by 127
Cerqueira, J., Catania, C., Sotiropoulos, I., Schubert, M. I., Kalisch, R., Almeida, O. F. X., Auer, D. P., & Sousa, N. (2005) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2005.01.003 · Cited by 127
Multiple session experimental pain measurement
Yarnitsky, D., Sprecher, E., Zaslansky, R., & Hemli, J. A. (1996) · Pain · doi:10.1016/0304-3959(96)03110-7 · Cited by 125
Breast tumor segmentation in 3D automatic breast ultrasound using Mask scoring R‐CNN
Lei, Y., He, X., Yao, J., Wang, T., Wang, L., Li, W., Curran, W. J., Liu, T., Xu, D. M., & Yang, X. (2020) · Medical Physics · doi:10.1002/mp.14569 · Cited by 127
Boyd, N. F., Martin, L. J., Gunasekara, A., Melnichouk, O., Maudsley, G., Peressotti, C., Yaffe, M. J., & Minkin, S. (2009) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-09-0107 · Cited by 125
KUO, T. Y., Skedros, J. G., & Bloebaum, R. D. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000059542.90854.ef · Cited by 125
Nyqvist, K. H., Rubertsson, C., Ewald, U., & Sjödén, P.-O. (1996) · Journal of Human Lactation · doi:10.1177/089033449601200318 · Cited by 124
Productivity Loss Due to Presenteeism Among Patients with Arthritis: Estimates from 4 Instruments
ZHANG, W., GIGNAC, M. A. M., BEATON, D., TANG, K., & ANIS, A. H. (2010) · The Journal of Rheumatology · doi:10.3899/jrheum.100123 · Cited by 124
In-chair movement: validity, reliability and implications for measuring sitting discomfort
Fenety, P. A., Putnam, C. A., & Walker, J. M. T. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(00)00003-x · Cited by 124
Schibler, A., Hall, G. L., Businger, F., Reinmann, B., Wildhaber, J. H., Cernelc, M., & Frey, U. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00226002 · Cited by 124
A Comparison of Four Indirect Methods of Assessing Utility Values in Rheumatoid Arthritis
Marra, C. A., Esdaile, J. M., Guh, D., Kopec, J. A., Brazier, J. E., Koehler, B. E., Chalmers, A., & Anis, A. H. (2004) · Medical Care · doi:10.1097/00005650-200411000-00012 · Cited by 123
Pauca, A. L., Kon, N. D., & O’Rourke, M. F. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh121 · Cited by 123
Zhou, L., Ng, H. K., Drautz‐Moses, D. I., Schuster, S. C., Beck, S., Kim, C., Chambers, J. C., & Loh, M. C. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-46875-5 · Cited by 123
Galvagno, S. M., Massey, M. S., Bouzat, P., Vesselinov, R. M., Levy, M. J., Millin, M. G., Stein, D. M., Scalea, T. M., & Hirshon, J. M. (2018) · Prehospital Emergency Care · doi:10.1080/10903127.2018.1489019 · Cited by 122
Collaborators, F. T. M. W. S., Bobrow, K. L., Quigley, M. A., Green, J., Reeves, G. K., & Beral, V (2013) · International Journal of Obesity · doi:10.1038/ijo.2012.76 · Cited by 122
The analysis of ordinal agreement data: beyond weighted kappa
Graham, P., & Jackson, R. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90173-x · Cited by 121
Shariff, M. K., Bird-Lieberman, E. L., O’Donovan, M., Abdullahi, Z., Liu, X., Blazeby, J. M., & Fitzgerald, R. C. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.01.029 · Cited by 121
Corris, P. A., Ellis, D. A., Hawkins, T., & Gibson, G. J. (1987) · Thorax · doi:10.1136/thx.42.4.285 · Cited by 121
Sapin, P. M., Schröder, K. M., Gopal, A. S., Smith, M. D., DeMaria, A. N., & King, D. L. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90869-9 · Cited by 121
Pharmacokineatic Aspects of Measurement of Glomerular Filtration Rate in the Dog: A Review
Heiene, R., & Moe, L. (1998) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.1998.tb02143.x · Cited by 120
Smallest detectable difference in radiological progression.
Lassere, M. N., Boers, M., van der Heijde, D. M. F. M., Boonen, A. E. R. C. H., Edmonds, J. P., Saudan, A., & Verhoeven, A. C. (1999) · PubMed · Cited by 120
Harris lines revisited: Prevalence, comorbidities, and possible etiologies
Papageorgopoulou, C., Suter, S. K., Rühli, F. J., & Siegmund, F. (2011) · American Journal of Human Biology · doi:10.1002/ajhb.21155 · Cited by 120
Comparison of the Timed 25-Foot and the 100-Meter Walk as Performance Measures in Multiple Sclerosis
Phan-Ba, R., Pace, A., Calay, P., Grodent, P., Douchamps, F., Hyde, R., Hotermans, C., Delvaux, V., Hansen, I., Moonen, G., et al. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968310397204 · Cited by 119
Pynsent, P. B. (2001) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.83b6.0830792 · Cited by 121
The relationship of intraocular pressure to intracranial pressure
Lashutka, M. K., Chandra, A. B., Murray, H. N., Phillips, G. S., & Hiestand, B. C. (2004) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2003.12.006 · Cited by 119
Goldblatt, R., Addas, A., Crull, D., Maghrabi, A., Levin, G. G., & Rubinyi, S. L. (2021) · Land · doi:10.3390/land10040410 · Cited by 117
The Agreement between Parent-Reported and Directly Measured Child Language and Parenting Behaviors
Bennetts, S. K., Mensah, F. K., Westrupp, E. M., Hackworth, N. J., & Reilly, S. (2016) · Frontiers in Psychology · doi:10.3389/fpsyg.2016.01710 · Cited by 118
Cooper, S.-M., Baker, J. S., Tong, R. J., Roberts, E., & Hanford, M. A. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2004.013078 · Cited by 118
SleepMonitor: Monitoring Respiratory Rate and Body Position During Sleep Using Smartwatch
Sun, X., Li, Q., Wu, Y., Tang, Y., & Cao, G. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3130969 · Cited by 118
Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
Massaroni, C., Presti, D. L., Formica, D., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19122758 · Cited by 117
REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER
Ingalls, J. G., Krick, J., Carey, S. J., Stauffer, J. R., Lowrance, P. J., Grillmair, C. J., Buzasi, D. L., Deming, D., Diamond-Lowe, H., Evans, T. M., et al. (2016) · The Astronomical Journal · doi:10.3847/0004-6256/152/2/44 · Cited by 117
Clinical Evaluation of a Fully-automatic Segmentation Method for Longitudinal Brain Tumor Volumetry
Meier, R., Knecht, U., Loosli, T., Bauer, S., Slotboom, J., Wiest, R., & Reyes, M. (2016) · Scientific Reports · doi:10.1038/srep23376 · Cited by 116
Metadata
- Authors
- Altman, D. G., & Bland, J. M.
- Affiliations
- Medical Research Council (GB)
- St George's, University of London (GB)
- Venue
- The Statistician
- Publisher
- JSTOR
- Published
- 1983-09
- Volume
- 32
- Issue
- 3
- Pages
- 307
- ISSN
- 0039-0526 (ISSN-L)
- OpenAlex
- W2133750711
- Semantic Scholar
- 029929987c1321e6880234bf0492689a7a379e38
- Cited by
- 4,300
- References
- 19
- Citations by year
- 2026: 73 · 2025: 158 · 2024: 221 · 2023: 230 · 2022: 238 · 2021: 239 · 2020: 245 · 2019: 207 · 2018: 186 · 2017: 174 · 2016: 173 · 2015: 145 · 2014: 165 · 2013: 145 · 2012: 151
- FWCI
- 25.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Royal Statistical Society Series D (The Statistician) (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- method comparison, measurement error, measurement agreement, regression analysis, bias and precision, diagnostic accuracy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.