CoChat

Urinary C-Peptide Creatinine Ratio Is a Practical Outpatient Tool for Identifying Hepatocyte Nuclear Factor 1-α/Hepatocyte Nuclear Factor 4-α Maturity-Onset Diabetes of the Young From Long-Duration Type 1 Diabetes

Open access
Besser, Rachel E.J., Shepherd, Maggie H., McDonald, Timothy J., Shields, Beverley M., Knight, Bridget A., Ellard, Sian, Hattersley, Andrew T. · 2011 · Diabetes Care
Cited by 133

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Hepatocyte nuclear factor 1-α (HNF1A)/hepatocyte nuclear factor 4-α (HNF4A) maturity-onset diabetes of the young (MODY) is frequently misdiagnosed as type 1 diabetes, and patients are inappropriately treated with insulin. Blood C-peptide can aid in the diagnosis of MODY, but practical reasons limit its widespread use. Urinary C-peptide creatinine ratio (UCPCR), a stable measure of endogenous insulin secretion, is a noninvasive alternative. We aimed to compare stimulated UCPCR in adults with HNF1A/4A MODY, type 1 diabetes, and type 2 diabetes. RESEARCH DESIGN AND METHODS: Adults with diabetes for ≥5years, without renal impairment, were studied (HNF1A MODY [n = 54], HNF4A MODY [n = 23], glucokinase MODY [n = 20], type 1 diabetes [n = 69], and type 2 diabetes [n = 54]). The UCPCR was collected in boric acid 120 min after the largest meal of the day and mailed for analysis. Receiver operating characteristic (ROC) curves were used to identify optimal UCPCR cutoffs to differentiate HNF1A/4A MODY from type 1 and type 2 diabetes. RESULTS: UCPCR was lower in type 1 diabetes than HNF1A/4A MODY (median [interquartile range]) (<0.02 nmol/mmol [<0.02 to <0.02] vs. 1.72 nmol/mmol [0.98–2.90]; P < 0.0001). ROC curves showed excellent discrimination (area under curve [AUC] 0.98) and identified a cutoff UCPCR of ≥0.2 nmol/mmol for differentiating HNF1A/4A MODY from type 1 diabetes (97% sensitivity, 96% specificity). UCPCR was lower in HNF1A/4A MODY than in type 2 diabetes (1.72 nmol/mmol [0.98–2.90] vs. 2.47 nmol/mmol [1.4–4.13]); P = 0.007). ROC curves showed a weak distinction between HNF1A/4A MODY and type 2 diabetes (AUC 0.64). CONCLUSIONS: UCPCR is a noninvasive outpatient tool that can be used to discriminate HNF1A and HNF4A MODY from long-duration type 1 diabetes. To differentiate MODY from type 1 diabetes of >5 years’ duration, UCPCR could be used to determine whether genetic testing is indicated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc10-1293

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 133

Metadata

Authors
Besser, R. E. J., Shepherd, M. H., McDonald, T. J., Shields, B. M., Knight, B. A., Ellard, S., & Hattersley, A. T.
Venue
Diabetes Care
Published
2011-01-20
Volume
34
Issue
2
Pages
286-291
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2172115272
Cited by
133
References
6
FWCI
6.39
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Urinary C-Peptide Creatinine Ratio Is a Practical Outpatient Tool for Identifying Hepatocyte Nuclear Factor 1-α/Hepatocyte Nuclear Factor 4-α Maturity-Onset Diabetes of the Young From Long-Duration Type 1 Diabetes. https://app.cochat.ai/papers/10.2337/dc10-1293
The paper
Besser, R. E. J., Shepherd, M. H., McDonald, T. J., Shields, B. M., Knight, B. A., Ellard, S., & Hattersley, A. T. (2011). Urinary C-Peptide Creatinine Ratio Is a Practical Outpatient Tool for Identifying Hepatocyte Nuclear Factor 1-α/Hepatocyte Nuclear Factor 4-α Maturity-Onset Diabetes of the Young From Long-Duration Type 1 Diabetes. Diabetes Care. https://doi.org/10.2337/dc10-1293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.