Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 12 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate a sensor-augmented insulin pump with a low glucose suspend (LGS) feature that automatically suspends basal insulin delivery for up to 2 h in response to sensor-detected hypoglycemia. RESEARCH DESIGN AND METHODS: The LGS feature of the Paradigm Veo insulin pump (Medtronic, Inc., Northridge, CA) was tested for 3 weeks in 31 adults with type 1 diabetes. RESULTS: There were 166 episodes of LGS: 66% of daytime LGS episodes were terminated within 10 min, and 20 episodes lasted the maximum 2 h. LGS use was associated with reduced nocturnal duration ≤2.2 mmol/L in those in the highest quartile of nocturnal hypoglycemia at baseline (median 46.2 vs. 1.8 min/day, P = 0.02 [LGS-OFF vs. LGS-ON]). Median sensor glucose was 3.9 mmol/L after 2-h LGS and 8.2 mmol/L at 2 h after basal restart. CONCLUSIONS: Use of an insulin pump with LGS was associated with reduced nocturnal hypoglycemia in those at greatest risk and was well accepted by patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device shuts off insulin delivery for up to 2 h once the interstitial glucose concentration reaches a preset threshold and reduces the duration of nocturnal hypoglycemia (123).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [123]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device shuts off insulin delivery for up to 2 h once the interstitial glucose concentration reaches a preset threshold and reduces the duration of nocturnal hypoglycemia (123).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [123]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Risk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 617
Self-citationDecreased Epinephrine Responses to Hypoglycemia during Sleep
Jones, T. W., Porter, P., Sherwin, R. S., Davis, E. A., O'Leary, P., Frazer, F., Byrne, G., Stick, S., & Tamborlane, W. V. (1998) · New England Journal of Medicine · doi:10.1056/nejm199806043382303 · Cited by 301
Raccah, D., Sulmont, V., Reznik, Y., Guerci, B., Renard, E., Hanaire, H., Jeandidier, N., & Nicolino, M. (2009) · Diabetes Care · doi:10.2337/dc09-0750 · Cited by 237
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
Monsod, T. P., Flanagan, D. E., Rife, F., Saenz, R., Caprio, S., Sherwin, R. S., & Tamborlane, W. V. (2002) · Diabetes Care · doi:10.2337/diacare.25.5.889 · Cited by 173
Response to Nocturnal Alarms Using a Real-Time Glucose Sensor
Buckingham, B. A., Block, J. M., Burdick, J., Kalajian, A., Kollman, C., Choy, M., Wilson, D. M., & Chase, P. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.440 · Cited by 115
Accuracy of a New Real-Time Continuous Glucose Monitoring Algorithm
Keenan, D. B., Cartaya, R., & Mastrototaro, J. J. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400114 · Cited by 82
Cited by
Items 101–180 of 180
Predictive Low-Glucose Suspend to Prevent Hypoglycemia
Pinsker, J. E., & Dassau, E. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0064 · Cited by 11
Hypoglycemia Prevention Using Low Glucose Suspend Systems
Bequette, B. W. (2014) · Lecture notes in bioengineering · doi:10.1007/978-3-642-54464-4_3 · Cited by 10
de Valk, H. W., Lablanche, S., Bosi, E., Choudhary, P., Silva, J. D., Castañeda, J., Vorrink, L., de Portu, S., & Cohen, O. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0222 · Cited by 9
Self-citationPetrovski, G., Khalaf, F. A., Hussain, K., Campbell, J., & Awwa, A. E. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0510-5 · Cited by 9
Inhaled Formoterol Diminishes Insulin-Induced Hypoglycemia in Type 1 Diabetes
Belfort‐DeAguiar, R., Naik, S., Hwang, J. J., Szepietowska, B., & Sherwin, R. S. (2015) · Diabetes Care · doi:10.2337/dc14-2472 · Cited by 8
The Evolution of Insulin Administration in Type 1 Diabetes
Pinnaro, C. T., & Tansey, M. (2021) · Journal of Diabetes Mellitus · doi:10.4236/jdm.2021.115021 · Cited by 9
Dassau, E., Lowe, C., Barr, C., Atlas, E., & Phillip, M. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02850.x · Cited by 7
Closed-loop insulin delivery in adults with type 1 diabetes
Kumareswaran, K. (2012) · Apollo (University of Cambridge) · doi:10.17863/cam.16644 · Cited by 7
Cengiz, E., Sherr, J. L., WEINZIMER, S. A., & Tamborlane, W. V. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.33 · Cited by 6
21st century diabetes care: a marriage between humans and technology
Murphy, H. R. (2013) · Trends in Endocrinology and Metabolism · doi:10.1016/j.tem.2012.12.006 · Cited by 7
Hypoglycemia at Night: A Cause for Alarm?
Amiel, S. A. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0290 · Cited by 6
Self-citationInsulin Pump Therapy in Type 1 Diabetes-Merging Technology with Diabetes Care
Thabit, H. (2012) · Current Research in Medicine · doi:10.3844/amjsp.2012.93.99 · Cited by 5
Islet cell transplantation: current status in the UK
Choudhary, P., PARROTT, N. R., Birtles, L., & Rutter, M. K. (2012) · Practical Diabetes · doi:10.1002/pdi.1707 · Cited by 5
Self-citationRecurrent severe hypoglycemia in Type 1 diabetes: potential for prevention?
Henriksen, M. M., Due-Andersen, R., Thorsteinsson, B., & Pedersen‐Bjergaard, U. (2014) · Diabetes Management · doi:10.2217/dmt.14.41 · Cited by 5
Thomakos, P., Mitrakou, A., Kepaptsoglou, O., Taraoune, I., Barreto, C., & Zoupas, C. (2019) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-0889-7598 · Cited by 5
Abraham, M. B., Smith, G. J., Nicholas, J. A., Fairchild, J. M., King, B. R., Ambler, G. R., Cameron, F. J., Davis, E. A., Jones, T. W., on Behalf of the PLGM Study Group, et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0205 · Cited by 5
Closing the Loop: Another Step Forward
Weinstock, R. S. (2011) · Diabetes Care · doi:10.2337/dc11-1217 · Cited by 5
Continuous Subcutaneous Insulin Infusion for Managing Diabetes: Women's Health Implications
Hood, D. G. (2012) · Nursing for Women s Health · doi:10.1111/j.1751-486x.2012.01749.x · Cited by 4
Nanotechnological Approach to the Treatment of Diabetes
Ramírez, A., Corro, G., Zehe, A., & Thomas, A. (2018) · American Journal of Medical Sciences and Medicine · doi:10.12691/ajmsm-6-2-1 · Cited by 4
Shah, V. N., Rewers, A. H., & Garg, S. K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00013-2 · Cited by 4
Online Glucose Prediction in Type-1 Diabetes by Neural Network Models
Zecchin, C. (2014) · Padua@research (University of Padova) · Cited by 9
Artificial pancreas: the bridge to a cure for type 1 diabetes
Thabit, H., Hovorka, R., & Evans, M. L. (2012) · European Diabetes Nursing · doi:10.1002/edn.207 · Cited by 6
Self-citationLumb, A. N. (2012) · Springer eBooks · doi:10.1007/978-0-85729-754-9_5 · Cited by 4
Upcoming Devices for Diabetes Management: The Artificial Pancreas as the Hallmark Device
Lee, S. W., & Welsh, J. B. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0303 · Cited by 4
Europe, D. I. A. C. O. R. P. I., costly, W. T. I. N. O., Thus, B. A. V. L., & diabetes., I. C. M. P. T. E. P. H. I. T. E. O. L. R. I. H. –. B. I. T. O. W. A. B. –. T. I. A. U. N. T. R. A. T. D. T. T. M. B. P. W. E. O. N. E. T. T. B. P. A. T. O. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.1515 · Cited by 4
Overview of Currently Available Insulin Delivery Systems
Fried, H. (2024) · Contemporary Endocrinology · doi:10.1007/978-3-031-75352-7_2 · Cited by 4
Cai, Q., Zhao, P., Chen, X., Yu, S., Guo, L., & Pan, Q. (2025) · Aging Medicine · doi:10.1002/agm2.70044 · Cited by 3
Banting Memorial Lecture 2013 A life in balance: wandering the pathways of control
Amiel, S. A. (2013) · Diabetic Medicine · doi:10.1111/dme.12351 · Cited by 3
Self-citationFanelli, C. G., Lucidi, P., Bolli, G. B., & Porcellati, F. (2018) · Endocrinology · doi:10.1007/978-3-319-44433-8_22 · Cited by 3
Modern strategies for management of glycaemia in type 1 diabetes
Neupane, S., & Evans, M. L. (2014) · Medicine · doi:10.1016/j.mpmed.2014.09.006 · Cited by 3
Self-citationManaging hypoglycemia in children: what the clinician needs to know before advising parents
Ly, T. T., & Jones, T. W. (2012) · Diabetes Management · doi:10.2217/dmt.12.73 · Cited by 4
Update on Treatment of Type 1 Diabetes in Childhood
Ludvigsson, J. (2013) · Current Pediatrics Reports · doi:10.1007/s40124-013-0012-x · Cited by 4
Control in Physiology and Medicine
Bequette, B. W. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-411557-6.00002-1 · Cited by 3
Biester, T., Remus, K., Holder, M., Aschemeier, B., Kieninger‐Baum, D., Wadien, T., Kordonouri, O., Danne, T., & Thomas, A. (2017) · Diabetologie und Stoffwechsel · doi:10.1055/s-0043-114867 · Cited by 3
New technical approach to the diabetes therapy
Dovč, K., & Battelino, T. (2020) · Minerva Pediatrics · doi:10.23736/s0026-4946.20.05865-x · Cited by 3
7 th Annual Symposium on Self-Monitoring of Blood Glucose (SMBG), May 8–10, 2014, Helsinki, Finland
Parkin, C. G., Mlinac, A., & Hinzmann, R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0239 · Cited by 2
Chawla, M. S., Chawla, P., Saboo, B., Chawla, R., Gangopadhyay, K. K., Kalra, S., Aravind, S. R., Sinha, B., Shah, T. U., Kesavadev, J., et al. (2022) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2022.102587 · Cited by 2
Papa, G. F. S., Cannarella, R., Finocchiaro, C., Anzaldi, M., Gruttadauria, G., Presti, D. L., Condorelli, R. A., Vignera, S. L., & Calogero, A. E. (2025) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2025.108984 · Cited by 2
Making Progress Toward Closed-Loop Insulin Pump Technology for Patients With Diabetes Mellitus
Garg, S. K., & Tamborlane, W. V. (2012) · Endocrine Practice · doi:10.4158/ep12252.or · Cited by 2
Fanelli, C. G., Lucidi, P., Bolli, G. B., & Porcellati, F. (2019) · Endocrinology · doi:10.1007/978-3-319-27316-7_22-2 · Cited by 2
Chow, E., & Heller, S. R. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch5 · Cited by 2
Chow, E., & Heller, S. R. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8684-8_34 · Cited by 2
Chow, E., & Heller, S. R. (2022) · Springer eBooks · doi:10.1007/978-3-030-90684-9_35 · Cited by 1
Scoping review of subcutaneous glucose monitoring techniques
Hrubá, E., Kubíček, J., & Augustýnek, M. (2025) · Measurement · doi:10.1016/j.measurement.2025.119940 · Cited by 1
Insulinothérapie en boucle fermée : vers le pancréas artificiel ambulatoire
Renard, É., Place, J., Pelletier, M.-É., & Farret, A. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70468-6 · Cited by 1
What is the role of sensor-augmented pump therapy in young children with Type 1 diabetes?
Lawson, M. L. (2012) · Diabetes Management · doi:10.2217/dmt.12.57 · Cited by 1
Лаптев, Д. Н. (2012) · Problems of Endocrinology · doi:10.14341/probl201258370-74 · Cited by 1
Interventional endocrinology: A futuristic perspective
Singla, R., & Singla, S. (2014) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.131221 · Cited by 1
Auf dem Weg zum „Closed-loop“-System: Bestandteile und Schritte
Thomas, A., Heinemann, L., & Freckmann, G. (2014) · Der Diabetologe · doi:10.1007/s11428-013-1127-y · Cited by 1
Thomas, A. (2018) · Diabetes aktuell · doi:10.1055/a-0805-2727 · Cited by 2
Fanelli, C. G., Lucidi, P., Bolli, G. B., & Porcellati, F. (2020) · Endocrinology · doi:10.1007/978-3-030-36694-0_22 · Cited by 2
Pickup, J. C. (2018) · Endocrinology · doi:10.1007/978-3-319-27317-4_22-1 · Cited by 1
Self-citationCanciani, G. N., Stewart, Z. A., & Murphy, H. R. (2017) · Wiley eBooks · doi:10.1002/9781119043805.ch16 · Cited by 1
Keenan, D. B., & Steil, G. M. (2014) · Wiley eBooks · doi:10.1002/9781118873434.ch51
Amiel, S. A. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch7
Self-citationImplantable pumps and artificial and bio‐artificial pancreas system
Tamborlane, W. V., & Palau‐Collazo, M. M. (2015) · Wiley eBooks · doi:10.1002/9781118387658.ch51
Benhamou, P., Debaty, I., Lerouvillois, S., Coulon, A.-L., Quemerais, M.-A., & Halimi, S. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70398-x · Cited by 3
Technologie ter optimalisatie van interventies en behandelresultaten bij kinderen met diabetes
Markowitza, J. T., Harringtona, K. R., & Laffel, L. M. (2014) · Nederlands Tijdschrift voor Diabetologie · doi:10.1007/s12467-014-0022-5
Chevremont, A., Collet-Gaudillat, C., Duvezin-Caubet, P., Franc, S., Gouet, D., Jan, P., Leguerrier, A.-M., Lopez, S., Ozenne, G., Plat, F., et al. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70475-3
Individuelle Therapieziele für Kleinkinder, Kinder und Jugendliche mit Diabetes
Kiess, W., Pfaeffle, R. W., & Kapellen, T. M. (2012) · Der Diabetologe · doi:10.1007/s11428-011-0813-x
Use of liraglutide in type 1 diabetes: implications for management
Simmons, D. S. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00459-3
Preventing severe hypoglycemia in children and adolescents with type 1 diabetes
Ly, T. T. (2013) · UWA Profiles and Research Repository (UWA)
Robust strategies for glucose control in type 1 diabetes
Tomás, A. R. (2015) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/56001
Siegmund, T. (2013) · Info Diabetologie · doi:10.1007/s15034-013-0468-3
Prevention of Hypoglycemia Using the Predicted Low Glucose Suspend System
Chase, H. P. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0119
4. Prevention and Management of Hypoglycemia in the Active Patient with Diabetes
Davis, S. N., & Evans, M. L. (2012) · Translational endocrinology & metabolism · doi:10.1210/team.9781936704200.ch4
Self-citationTauschmann, M., & Hovorka, R. (2016) · Springer eBooks · doi:10.1007/978-3-319-40242-0_14
Miljković, V. (2018) · Биомедицинска истраживања · doi:10.7251/bii1801037b
Trence, D., & Hirsch, I. B. (2015) · Wiley eBooks · doi:10.1002/9781118387658.ch49
Sharifi, A., McAuley, S. A., Horsburgh, J. C., Loh, M., Jenkins, A. J., MacIsaac, R. J., & O'Neal, D. N. (2014)
Bertachi, A. H. (2019) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Fanelli, C. G., Lucidi, P., Bolli, G. B., & Porcellati, F. (2018) · Endocrinology · doi:10.1007/978-3-319-27316-7_22-1 · Cited by 2
Pickup, J. C. (2018) · Endocrinology · doi:10.1007/978-3-319-45015-5_22
Self-citationDassau, E., Lowe, C., Barr, C., Atlas, E., & Phillip, M. (2012) · Wiley eBooks · doi:10.1002/9781118321508.ch4
Controlling Human Physiology via Drugs and Devices
Hahn, J., & Howsmon, D. P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-14081-5.00009-x
Impacto del inicio de la monitorización flash de glucosa en pacientes adultos con diabetes tipo 1
Sahagún, R. J. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/72390
An overview on recent developments in insulin pump therapy with a regional perspective
Muzammil, F. M., shehzad, H., Shriya, S. R., Tayb, T., Iqbal, Y., & Houni, A. E. (2025) · Journal of Research in Clinical Medicine · doi:10.34172/jrcm.025.34767
Management of Acute and Recurrent Hypoglycaemia
McCrimmon, R. J. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch8
Soigner la maladie chronique : quand le travail d'équipement révèle autonomie et attachements
Vaillant, M.-F. (2012) · theses.fr (ABES) · doi:10.70675/4ac51747z9e12z4142za317zf070c804ed62
Metadata
- Authors
- Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A.
- Affiliations
- King's College London (GB)
- Medtronic (United States) (US)
- University of Cambridge (GB)
- Harrogate District Hospital (GB)
- Bournemouth Diabetes and Endocrine Centre, Bournemouth District General Hospital, Bournemouth, U.K.
- Newcastle University (GB)
- Corresponding author
- Choudhary, Pratik
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2011-08-19
- Volume
- 34
- Issue
- 9
- Pages
- 2023-2025
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC3161284
- OpenAlex
- W2071497593
- Cited by
- 175
- References
- 14
- Citations by year
- 2025: 3 · 2024: 4 · 2022: 2 · 2021: 3 · 2020: 7 · 2019: 5 · 2018: 14 · 2017: 12 · 2016: 16 · 2015: 17 · 2014: 24 · 2013: 30 · 2012: 33
- FWCI
- 23.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Diabetes Care (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- insulin pump therapy, low glucose suspend, sensor-augmented pump, type 1 diabetes, nocturnal hypoglycemia, continuous glucose monitoring, hypoglycemia detection
- MeSH terms
- Adult, Circadian Rhythm, Female, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
