The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Real-Time Continuous Glucose Monitoring Significantly Reduces Severe Hypoglycemia in Hypoglycemia-Unaware Patients With Type 1 Diabetes
Open accessAbstract
OBJECTIVE: To evaluate the effect of continuous glucose monitoring (CGM) on the frequency of severe hypoglycemia (SH) in patients with established hypoglycemia unawareness. RESEARCH DESIGN AND METHODS: We conducted a retrospective audit of 35 patients with type 1 diabetes and problematic hypoglycemia unawareness, despite optimized medical therapy (continuous subcutaneous insulin infusion/multiple daily insulin injections), who used CGM for >1 year. RESULTS: Over a 1-year follow-up period, the median rates of SH were reduced from 4.0 (interquartile range [IQR] 0.75–7.25) episodes/patient-year to 0.0 (0.0–1.25) episodes/patient-year (P < 0.001), and the mean (±SD) rates were reduced from 8.1 ± 13 to 0.6 ± 1.2 episodes/year (P = 0.005). HbA1c was reduced from 8.1 ± 1.2% to 7.6 ± 1.0% over the year (P = 0.005). The mean Gold score, measured in 19 patients, did not change: 5.1 ± 1.5 vs. 5.2 ± 1.9 (P = 0.67). CONCLUSIONS: In a specialist experienced insulin pump center, in carefully selected patients, CGM reduced SH while improving HbA1c but failed to restore hypoglycemia awareness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Self-citationHopkins, D., Lawrence, I., Mansell, P., Thompson, G., Amiel, S., Campbell, M., & Heller, S. (2012) · Diabetes Care · doi:10.2337/dc11-1579 · Cited by 265
Self-citationJuvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
Self-citationDavis, S. N., Mann, S., Galassetti, P., Neill, R. A., Tate, D., Ertl, A. C., & Costa, F. (2000) · Diabetes · doi:10.2337/diabetes.49.11.1897 · Cited by 100
Cited by
6. Glycemic Targets: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s006 · Cited by 762
Hypoglycaemia in diabetes mellitus: epidemiology and clinical implications
Frier, B. M. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.170 · Cited by 481
van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M. J., Pillay, K., de Beaufort, C., Craig, M. E., Hanas, R., Acerini, C. L., & Maahs, D. M. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12190 · Cited by 316
Metadata
- Authors
- Choudhary, P., Ramasamy, S., Green, L., Gallen, G., Pender, S., Brackenridge, A., Amiel, S. A., & Pickup, J. C.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2013-11-13
- Volume
- 36
- Issue
- 12
- Pages
- 4160-4162
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2121866362
- Cited by
- 160
- References
- 6
- FWCI
- 16.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.