Recovery of Hypoglycemia Awareness in Long-standing Type 1 Diabetes: A Multicenter 2 × 2 Factorial Randomized Controlled Trial Comparing Insulin Pump With Multiple Daily Injections and Continuous With Conventional Glucose Self-monitoring (HypoCOMPaSS)
Open accessThe DOI matches its Crossref record; 38 of the 40 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether impaired awareness of hypoglycemia (IAH) can be improved and severe hypoglycemia (SH) prevented in type 1 diabetes, we compared an insulin pump (continuous subcutaneous insulin infusion [CSII]) with multiple daily injections (MDIs) and adjuvant real-time continuous glucose monitoring (RT) with conventional self-monitoring of blood glucose (SMBG). RESEARCH DESIGN AND METHODS: A 24-week 2 × 2 factorial randomized controlled trial in adults with type 1 diabetes and IAH was conducted. All received comparable education, support, and congruent therapeutic targets aimed at rigorous avoidance of biochemical hypoglycemia without relaxing overall control. Primary end point was between-intervention difference in 24-week hypoglycemia awareness (Gold score). RESULTS: A total of 96 participants (mean diabetes duration 29 years) were randomized. Overall, biochemical hypoglycemia (≤3.0 mmol/L) decreased (53 ± 63 to 24 ± 56 min/24 h; P = 0.004 [t test]) without deterioration in HbA1c. Hypoglycemia awareness improved (5.1 ± 1.1 to 4.1 ± 1.6; P = 0.0001 [t test]) with decreased SH (8.9 ± 13.4 to 0.8 ± 1.8 episodes/patient-year; P = 0.0001 [t test]). At 24 weeks, there was no significant difference in awareness comparing CSII with MDI (4.1 ± 1.6 vs. 4.2 ± 1.7; difference 0.1; 95% CI −0.6 to 0.8) and RT with SMBG (4.3 ± 1.6 vs. 4.0 ± 1.7; difference −0.3; 95% CI −1.0 to 0.4). Between-group analyses demonstrated comparable reductions in SH, fear of hypoglycemia, and insulin doses with equivalent HbA1c. Treatment satisfaction was higher with CSII than MDI (32 ± 3 vs. 29 ± 6; P = 0.0003 [t test]), but comparable with SMBG and RT (30 ± 5 vs. 30 ± 5; P = 0.79 [t test]). CONCLUSIONS: Hypoglycemia awareness can be improved and recurrent SH prevented in long-standing type 1 diabetes without relaxing HbA1c. Similar biomedical outcomes can be attained with conventional MDI and SMBG regimens compared with CSII/RT, although satisfaction was higher with CSII.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hypoglycaemia unawareness can improve with edu cation, support, and glucose targets that are aimed at avoiding biochemical hypoglycaemia, while maintaining overall metabolic control.107”
From Type 1 diabetes (2018) · cites this paper as [107]
In the citing paper
“People with diabetes who continue to have frequent and severe hypoglycemia and/or impaired awareness of hypoglycemia, despite educational interventions, may benefit from continuous subcutaneous insulin infusion (CSII) therapy or continuous glucose monitoring (CGM) or both (i.e. a sensor augmented pump), to reduce the risk of severe hypoglycemia (44)(45)(46)(47).”
From Hypoglycemia (2018) · cites this paper as [45]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389
Self-citationRisk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Handbook of Psychology and Diabetes
(2013) · Routledge eBooks · doi:10.4324/9781315077369 · Cited by 661
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 617
Research works printed but not linked: 1
- Speight, 2013, Psychometric Validation of a Novel Measure of Impaired Awareness of Hypoglycaemia; the Hypoglycaemia Awareness Questionnaire (HypoA-Q), LB8
Cited by
Items 201–238 of 238
Acute Complications of Diabetes
Hirsch, I. B., & Childs, B. P. (2017) · American Diabetes Association eBooks · doi:10.2337/9781580405690.ch09 · Cited by 1
Insulin pumps: Great devices, but you still have to press the button
Nasr, C. E. (2015) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.82a.15047
Haase, M., Kahle, M., Janert, M., Meier, J. J., & Nauck, M. A. (2017) · Diabetes Obesity and Metabolism · doi:10.1111/dom.12868 · Cited by 1
Biester, T., & Wizemann, E. (2017) · Diabetologie und Stoffwechsel · doi:10.1055/s-0043-100389 · Cited by 1
Effect of real‐time continuous glucose monitoring on hypoglycemia in adult type 1 diabetes patients
Jia, W. (2017) · Journal of Diabetes Investigation · doi:10.1111/jdi.12722
Wizemann, E., & Biester, T. (2018) · Diabetes aktuell · doi:10.1055/a-0618-4826
Walkinshaw, E. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Self-citationProblem solving in type 1 diabetes for primary care nurses–part 2
Morris, D. (2019) · Independent Nurse · doi:10.12968/indn.2019.12.25
Islet Transplantation in Type 1 Diabetes Mellitus With Hypoglycaemic Unawareness
Agarwal, G., & Cross, S. (2020) · Journal of the Nuffield Department of Surgical Sciences · doi:10.37707/jnds.v1i4.74
Speight, J., & Pouwer, F. (2019) · University of Southern Denmark Research Portal (University of Southern Denmark) · Cited by 2
Self-citationContinuous and Intermittent Glucose Monitoring in 2020
Bode, B. W., Battelino, T., & Dovč, K. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.2502
Insulins and Insulin Delivery Devices
Choudhary, P., & Jacob, P. (2022) · doi:10.1093/med/9780198870197.003.0252 · Cited by 1
Fanelli, C. G., Lucidi, P., Bolli, G. B., & Porcellati, F. (2018) · Endocrinology · doi:10.1007/978-3-319-27316-7_22-1 · Cited by 2
Manuscripts Reviewed for the 2014 Yearbook
(2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.1515
1) Progression of the Advanced Technology and Therapy for Diabetes Mellitus
Matsuhisa, M., & Kuroda, A. (2021) · Nihon Naika Gakkai Zasshi · doi:10.2169/naika.110.420
Rotondi, M. A., Wong, O. C. Y., Riddell, M. C., & Perkins, B. A. (2022) · doi:10.2337/figshare.20173937.v1
Rotondi, M. A., Wong, O. C. Y., Riddell, M. C., & Perkins, B. A. (2022) · doi:10.2337/figshare.20173937
Boswell, L., Perea, V., Amor, A. J., Seguí, N., Bellart, J., Roca, D., Giménez, M., Conget, I., & Vinagre, I. (2023) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2022.02.023 · Cited by 18
Hypoglycemia: Diagnosis, Management, and Prevention
Faradji, R. N., Uribe-Wiechers, A. C., & de la Maza, E. S. (2023) · Springer eBooks · doi:10.1007/978-3-031-25519-9_45 · Cited by 2
Hillson, R. (2023) · Practical Diabetes · doi:10.1002/pdi.2462
Iqbal, A., Chow, E., Jones, T. W., & Heller, S. R. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch40
Self-citationNew Technologies for Insulin Administration
Forde, H. E., & Choudhary, P. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch33
Deniz, M. S. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1006990 · Cited by 1
Haak, T., Fritsche, A., Füchtenbusch, M., Gehr, B., Gölz, S., Kröger, J., Siegmund, T., Ziegler, R., Droßel, D., Fuchs, S., et al. (2025) · Die Diabetologie · doi:10.1007/s11428-024-01280-z
(2022) · American Diabetes Association eBooks · doi:10.2337/9781580407700.ch04
Thuraisingam, S., Halliday, J. A., Søholm, U., Holmes‐Truscott, E., Hendrieckx, C., Skinner, T. C., Versace, V. L., & Speight, J. (2025) · Contemporary Clinical Trials Communications · doi:10.1016/j.conctc.2025.101513
Self-citationSøholm, U., Holmes‐Truscott, E., Amiel, S. A., de Galan, B. E., Pedersen‐Bjergaard, U., McCrimmon, R. J., Heller, S. R., Evans, M. L., Mader, J. K., Choudhary, P., et al. (2026) · Diabetic Medicine · doi:10.1111/dme.70231
Self-citationLin, Y. K., Hepworth, E., Lucien, J., Agni, A., Martin-Schwarze, A. M., Newman, S., Marinec, N. S., Aikens, J. E., Spino, C., Pop-Busui, R., et al. (2026) · Contemporary Clinical Trials · doi:10.1016/j.cct.2026.108261
Therapie des Typ-1-Diabetes: Kurzfassung der S3-Leitlinie. Version 5.0, AWMF-Registernummer: 057-013
Haak, T., Fritsche, A., Füchtenbusch, M., Gehr, B., Gölz, S., Kröger, J., Siegmund, T., Ziegler, R., Droßel, D., Fuchs, S., et al. (2026) · Die Diabetologie · doi:10.1007/s11428-026-01467-6
Hayek, A. A., Zahrani, W. M. A., Alotaibi, H. F., Saleh, J. Y., & Dawish, M. A. A. (2026) · Primary care diabetes · doi:10.1016/j.pcd.2026.04.002 · Cited by 1
Why glycemic control remains suboptimal in type 1 diabetes in the era of advanced technologies?
Joubert, M. (2026) · Diabetes & Metabolism · doi:10.1016/j.diabet.2026.101763
Ralston, J. D., Anderson, M. L., Ng, J., Bashir, A., Ehrlich, K. J., Burns-Hunt, D., Cotton, M., Hansell, L. D., Hsu, C., Hunt, H., et al. (2026) · Journal of General Internal Medicine · doi:10.1007/s11606-026-10491-7
Self-citationFacteurs de déséquilibre du diabète de type 1
Joubert, M. (2026) · EMC - Traité de médecine AKOS · doi:10.1016/s1634-6939(26)44170-8
Factores que provocan descompensación en la diabetes tipo 1
Joubert, M. (2026) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(26)52262-1
Digital Health Technologies and Hypoglycaemia
Villard, O., & Renard, É. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_24
Haak, T., Fritsche, A., Füchtenbusch, M., Gehr, B., Gölz, S., Kröger, J., Siegmund, T., Ziegler, R., Droßel, D., Fuchs, S., et al. (2026) · Diabetologie und Stoffwechsel · doi:10.1055/a-2884-8129
Untitled work
Diabetes Canada Clinical Practice Guidelines Expert Committee (n.d.) · Diabetes Canada
Metadata
- Authors
- Little, S. A., Leelarathna, L., Walkinshaw, E., Tan, H. K., Chapple, O., Lubina-Solomon, A., Chadwick, T. J., Barendse, S., Stocken, D. D., Brennand, C., Marshall, S. M., Wood, R., Speight, J., Kerr, D., Flanagan, D., Heller, S. R., Evans, M. L., & Shaw, J. A. M.
- Affiliations
- Newcastle University (GB)
- University of Cambridge (GB)
- University of Sheffield (GB)
- Peninsula College of Medicine and Dentistry (GB)
- Royal Bournemouth Hospital (GB)
- AHP Research, Hornchurch, U.K.
- Deakin University (AU)
- Bournemouth University (GB)
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2014-07-12
- Volume
- 37
- Issue
- 8
- Pages
- 2114-2122
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2098815585
- Cited by
- 237
- References
- 40
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 24 · 2023: 17 · 2022: 22 · 2021: 12 · 2020: 23 · 2019: 28 · 2018: 27 · 2017: 19 · 2016: 22 · 2015: 15 · 2014: 4
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (publishedVersion)
- Deakin Research Online (Deakin University) (submittedVersion)
- Figshare (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- National Institute for Health and Care Research (ACF-2013-24-004)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- impaired awareness of hypoglycemia, type 1 diabetes, insulin pump therapy, multiple daily insulin injections, continuous glucose monitoring, self-monitoring of blood glucose, fear of hypoglycemia, treatment satisfaction, long-standing diabetes, HbA1c, glycemic control, insulin dose reduction
- MeSH terms
- Adolescent, Adult, Aged, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Insulin, Insulin Infusion Systems, Male, Middle Aged, Recurrence, Blood Glucose Self-Monitoring, Patient Satisfaction, Infusions, Subcutaneous, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.