CoChat

Recovery of Hypoglycemia Awareness in Long-standing Type 1 Diabetes: A Multicenter 2 × 2 Factorial Randomized Controlled Trial Comparing Insulin Pump With Multiple Daily Injections and Continuous With Conventional Glucose Self-monitoring (HypoCOMPaSS)

Open access

The DOI matches its Crossref record; 38 of the 40 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine whether impaired awareness of hypoglycemia (IAH) can be improved and severe hypoglycemia (SH) prevented in type 1 diabetes, we compared an insulin pump (continuous subcutaneous insulin infusion [CSII]) with multiple daily injections (MDIs) and adjuvant real-time continuous glucose monitoring (RT) with conventional self-monitoring of blood glucose (SMBG). RESEARCH DESIGN AND METHODS: A 24-week 2 × 2 factorial randomized controlled trial in adults with type 1 diabetes and IAH was conducted. All received comparable education, support, and congruent therapeutic targets aimed at rigorous avoidance of biochemical hypoglycemia without relaxing overall control. Primary end point was between-intervention difference in 24-week hypoglycemia awareness (Gold score). RESULTS: A total of 96 participants (mean diabetes duration 29 years) were randomized. Overall, biochemical hypoglycemia (≤3.0 mmol/L) decreased (53 ± 63 to 24 ± 56 min/24 h; P = 0.004 [t test]) without deterioration in HbA1c. Hypoglycemia awareness improved (5.1 ± 1.1 to 4.1 ± 1.6; P = 0.0001 [t test]) with decreased SH (8.9 ± 13.4 to 0.8 ± 1.8 episodes/patient-year; P = 0.0001 [t test]). At 24 weeks, there was no significant difference in awareness comparing CSII with MDI (4.1 ± 1.6 vs. 4.2 ± 1.7; difference 0.1; 95% CI −0.6 to 0.8) and RT with SMBG (4.3 ± 1.6 vs. 4.0 ± 1.7; difference −0.3; 95% CI −1.0 to 0.4). Between-group analyses demonstrated comparable reductions in SH, fear of hypoglycemia, and insulin doses with equivalent HbA1c. Treatment satisfaction was higher with CSII than MDI (32 ± 3 vs. 29 ± 6; P = 0.0003 [t test]), but comparable with SMBG and RT (30 ± 5 vs. 30 ± 5; P = 0.79 [t test]). CONCLUSIONS: Hypoglycemia awareness can be improved and recurrent SH prevented in long-standing type 1 diabetes without relaxing HbA1c. Similar biomedical outcomes can be attained with conventional MDI and SMBG regimens compared with CSII/RT, although satisfaction was higher with CSII.

Overview

Integrity signals

Registry

Crossref · 10.2337/dc14-0030

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Speight, 2013, Psychometric Validation of a Novel Measure of Impaired Awareness of Hypoglycaemia; the Hypoglycaemia Awareness Questionnaire (HypoA-Q), LB8

Cited by

See all 238

Metadata

Authors
Little, S. A., Leelarathna, L., Walkinshaw, E., Tan, H. K., Chapple, O., Lubina-Solomon, A., Chadwick, T. J., Barendse, S., Stocken, D. D., Brennand, C., Marshall, S. M., Wood, R., Speight, J., Kerr, D., Flanagan, D., Heller, S. R., Evans, M. L., & Shaw, J. A. M.
Affiliations
  • Newcastle University (GB)
  • University of Cambridge (GB)
  • University of Sheffield (GB)
  • Peninsula College of Medicine and Dentistry (GB)
  • Royal Bournemouth Hospital (GB)
  • AHP Research, Hornchurch, U.K.
  • Deakin University (AU)
  • Bournemouth University (GB)
Venue
Diabetes Care
Published
2014-07-12
Volume
37
Issue
8
Pages
2114-2122
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2098815585
Cited by
237
References
40
Citations by year
2026: 11 · 2025: 13 · 2024: 24 · 2023: 17 · 2022: 22 · 2021: 12 · 2020: 23 · 2019: 28 · 2018: 27 · 2017: 19 · 2016: 22 · 2015: 15 · 2014: 4
FWCI
16.09
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (publishedVersion)
  • Deakin Research Online (Deakin University) (submittedVersion)
  • Figshare (submittedVersion)
  • Figshare (submittedVersion, cc-by)
  • Newcastle University ePrints (Newcastle Univesity)
Funders
National Institute for Health and Care Research (ACF-2013-24-004)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
impaired awareness of hypoglycemia, type 1 diabetes, insulin pump therapy, multiple daily insulin injections, continuous glucose monitoring, self-monitoring of blood glucose, fear of hypoglycemia, treatment satisfaction, long-standing diabetes, HbA1c, glycemic control, insulin dose reduction
MeSH terms
Adolescent, Adult, Aged, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Insulin, Insulin Infusion Systems, Male, Middle Aged, Recurrence, Blood Glucose Self-Monitoring, Patient Satisfaction, Infusions, Subcutaneous, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.