Early detection of hypoglycemia in type 1 diabetes using heart rate variability measured by a wearable device
Abstract
OBJECTIVE: Changes in heart rate variability (HRV) occur at the initiation of hypoglycemia due to sympathetic nervous system activity. We investigated the use of HRV detection by a wearable device as an early alert for hypoglycemia. RESEARCH DESIGN AND METHODS: This proof-of-principle study included 23 patients with type 1 diabetes (14 women, mean age 42 ± 11 years). Patients wore a VitalConnect HealthPatch for 5 days. Hypoglycemia was defined as glucose ≤70 mg/dL (≤3.9 mmol/L) by fingerstick measurement. HRV was analyzed in standardized periods before the hypoglycemic event. RESULTS: Sixty-six hypoglycemic events were recorded. Hypoglycemia caused a typical HRV pattern in 36 (55%) of the hypoglycemic events. Eighteen events (27%) showed an atypical pattern. Ten events were unclassified (15%), and two did not display a change in HRV (3%). CONCLUSIONS: Hypoglycemia causes early changes in HRV that can be detected by a wearable device. Measuring real-time HRV seems promising for early hypoglycemia detection.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hypoglycemia causes changes in physiological parameters.
“Hypoglycemia is a frequent and dangerous complication of diabetes (1), causing changes in physiological parameters (2,3).”
From Noninvasive Hypoglycemia Detection in People With Diabetes Using Smartwatch Data (2023) · cites this paper as [2]
Prior work was generated from small cohorts (the largest cohort of 70 individuals), raising questions of the generalizability of their findings.
“Second, prior work was generated from small cohorts (the largest cohort of 70 individuals), that raise questions of the generalizability of their findings5,22–32.”
From Sleep and temperature data from wearable devices support noninvasive detection of diabetes mellitus in a large-scale, retrospective analysis (2026) · cites this paper as [24]
Prior work typically uses less than a day of input.
“First, where prior work typically uses less than a day of input5,22–32, we assess the impact of longitudinal input windows ranging up to multiple weeks and demonstrate improved sensitivity with longer windows (AUROC increases by 0.15 from 1-night to 21-night models, in balanced and imbalanced cohorts).”
From Sleep and temperature data from wearable devices support noninvasive detection of diabetes mellitus in a large-scale, retrospective analysis (2026) · cites this paper as [24]
Cites
Heart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820 · see citing works
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389 · see citing works
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651 · see citing works
International Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608 · see citing works
Short-Term Heart Rate Variability—Influence of Gender and Age in Healthy Subjects
Voss, A., Schroeder, R., Heitmann, A., Peters, A., & Perz, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118308 · Cited by 480 · see citing works
The International Hypoglycaemia Study Group (2016) · Diabetologia · doi:10.1007/s00125-016-4146-6 · Cited by 362 · see citing works
Liao, D., Barnes, R. W., Chambless, L. E., Simpson, R. J., Sorlie, P. D., HEISS, G. M., & The ARIC Investigators (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80260-4 · Cited by 331 · see citing works
Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
Merri, M., Farden, D. C., Mottley, J. G., & Titlebaum, E. L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43621 · Cited by 248 · see citing works
Tanenberg, R. J., Newton, C. A., & Drake, A. J. (2010) · Endocrine Practice · doi:10.4158/ep09260.cr · Cited by 225 · see citing works
Minimizing Hypoglycemia in Diabetes
International Hypoglycaemia Study Group (2015) · Diabetes Care · doi:10.2337/dc15-0279 · Cited by 213 · see citing works
Jaiswal, M., McKeon, K., Comment, N., Henderson, J., Swanson, S., Plunkett, C. D., Nelson, P. W., & Pop‐Busui, R. (2014) · Diabetes Care · doi:10.2337/dc14-0445 · Cited by 69 · see citing works
Janssen, M. M., Snoek, F. J., & Heine, R. J. (2000) · Diabetes Care · doi:10.2337/diacare.23.4.529 · Cited by 57 · see citing works
Cichosz, S. L., Frystyk, J., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814549830 · Cited by 44 · see citing works
Silva, T. P., Rolim, L. C., Filho, C. S., Zimmermann, L. M., Malerbi, F. K., & Dib, S. A. (2016) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2830 · Cited by 28 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160 · see citing works
Noninvasive Hypoglycemia Detection in People With Diabetes Using Smartwatch Data
Lehmann, V., Föll, S., Maritsch, M., van Weenen, E., Kraus, M., Lagger, S., Odermatt, K., Albrecht, C., Fleisch, E., Zueger, T., et al. (2023) · Diabetes Care · doi:10.2337/dc22-2290 · Cited by 47 · see citing works
Towards Wearable-based Hypoglycemia Detection and Warning in Diabetes
Maritsch, M., Föll, S., Lehmann, V., Bérubé, C., Kraus, M., Feuerriegel, S., Kowatsch, T., Züger, T., Stettler, C., Fleisch, E., et al. (2020) · Extended Abstracts of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3334480.3382808 · Cited by 35 · see citing works
Koeneman, M., Olde Bekkink, M., Meijel, L. V., Bredie, S., & de Galan, B. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211007485 · Cited by 11 · see citing works
Self-citationMendez, C., Kaykayoglu, C. A., Bähler, T., Künzler, J., Lizoain, A., Rothenbühler, M., Schmidt, M. H., Laimer, M., & Witthauer, L. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251319800 · Cited by 10 · see citing works
Viswanath, V. K., Navaneethan, S., Burks, J. H., Soltani, S., Kasl, P., Hartogensis, W., Dilchert, S., Hecht, F. M., Mason, A. E., Wang, E. J., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01501-0
- Authors
- Olde Bekkink, M., Koeneman, M., de Galan, B. E., & Bredie, S. J.
- Affiliations
- Department of Internal Medicine, Radboud University Medical Center, Nijmegen, the Netherlands
- Radboud University Medical Center (NL)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2019-03-11
- Volume
- 42
- Issue
- 4
- Pages
- 689-692
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2922249064
- Cited by
- 58
- References
- 14
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 8 · 2023: 12 · 2022: 7 · 2021: 8 · 2020: 9 · 2019: 1
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Funders
- Dutch Diabetes Research Foundation (2016.30.004)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- hypoglycemia, type 1 diabetes, heart rate variability, wearable devices, sympathetic activity, real-time monitoring
- MeSH terms
- Wearable Electronic Devices, Adult, Diabetes Mellitus, Type 1, Female, Heart Rate, Humans, Hypoglycemia, Male, Middle Aged, Early Diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review