Diabeloop DBLG1 Closed-Loop System Enables Patients With Type 1 Diabetes to Significantly Improve Their Glycemic Control in Real-Life Situations Without Serious Adverse Events: 6-Month Follow-up
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To analyze safety and efficacy of the Diabeloop Generation 1 (DBLG1) hybrid closed-loop artificial pancreas system in patients with type 1 diabetes in real-world conditions. RESEARCH DESIGN AND METHODS: After a 1-week run-in period with their usual pump, 25 patients were provided the commercial DBLG1 system. The results are presented on time in range (TIR) and HbA1c over 6 months. RESULTS: The mean (SD; range) age of patients was 43 (13.8; 25–72) years. At baseline, the mean HbA1c and TIR 70–180 mg/dL were, respectively, 7.9% (0.93; 5.6–8.5%) [63 mmol/mol (10; 38–69 mmol/mol)] and 53% (16.4; 21–85%). One patient stopped using the system after 2 months. At 6 months, the mean HbA1c decreased to 7.1% [54 mmol/mol] (P < 0.001) and TIR 70–180 mg/dL increased to 69.7% (P < 0.0001). TIR <70 mg/dL decreased from 2.4 to 1.3% (P = 0.03), and TIR <54 mg/dL decreased from 0.32 to 0.24% (P = 0.42). No serious adverse event was reported during the study. CONCLUSIONS: The ability of the DBLG1 system to significantly improve glycemic control in real-world conditions, without serious adverse events, was confirmed in this follow-up study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Benhamou, P.-Y., Franc, S., Reznik, Y., Thivolet, C., Schaepelynck, P., Renard, E., Guerci, B., Chaillous, L., Lukas-Croisier, C., Jeandidier, N., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30003-2 · Cited by 217
Self-citationOne year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Real-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Pinsker, J. E., Müller, L., Constantin, A., Leas, S., Manning, M., McElwee Malloy, M., Singh, H., & Habif, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0388 · Cited by 147
Cited by
A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Garcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Benhamou, P., Adenis, A., Lebbad, H., Tourki, Y., Heredia, M., Gehr, B., Franc, S., & Charpentier, G. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15008 · Cited by 35
Self-citationChico, A., Navas de Solís, S., Lainez, M., Rius, F., & Cuesta, M. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0449 · Cited by 14
Metadata
- Authors
- Amadou, C., Franc, S., Benhamou, P.-Y., Lablanche, S., Huneker, E., Charpentier, G., & Penfornis, A.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2021-01-11
- Volume
- 44
- Issue
- 3
- Pages
- 844-846
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3119339852
- Cited by
- 59
- References
- 4
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diabeloop DBLG1 Closed-Loop System Enables Patients With Type 1 Diabetes to Significantly Improve Their Glycemic Control in Real-Life Situations Without Serious Adverse Events: 6-Month Follow-up. https://app.cochat.ai/papers/10.2337/dc20-1809
- The paper
- Amadou, C., Franc, S., Benhamou, P.-Y., Lablanche, S., Huneker, E., Charpentier, G., & Penfornis, A. (2021). Diabeloop DBLG1 Closed-Loop System Enables Patients With Type 1 Diabetes to Significantly Improve Their Glycemic Control in Real-Life Situations Without Serious Adverse Events: 6-Month Follow-up. Diabetes Care. https://doi.org/10.2337/dc20-1809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.