Cited by 72Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

Transitioning of people with type 1 diabetes from multiple daily injections and self-monitoring of blood glucose directly to MiniMed 780G advanced hybrid closed-loop system: a two-center, randomized, controlled study

Open access
Matejko, Bartłomiej, Juza, Anna, Kieć-Wilk, Beata, Cyranka, Katarzyna, Krzyżowska, Sabina, Chen, Xiaoxiao, Cohen, Ohad, Da Silva, Julien +2 more·2022·Diabetes Care

Published version of a preprint

Abstract

OBJECTIVE: The aim of this study was to evaluate the outcomes of transitioning to the MiniMed 780G advanced hybrid closed-loop (AHCL) system in adult individuals with type 1 diabetes mellitus (T1DM) naive to continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) technologies. RESEARCH DESIGN AND METHODS: This was a two-center, randomized, controlled, parallel-group trial with evaluation of individuals with T1DM aged 26-60 years managed with multiple daily injections (MDI) and self-monitoring of blood glucose (BGM) with HbA1c <10%. RESULTS: A total of 41 participants were recruited and randomized to either the AHCL (n = 20) or the MDI+BGM (n = 21) group, and 37 participants (mean ± SD age 40.3 ± 8.0 years, duration of diabetes 17.3 ± 12.1 years, BMI 25.1 ± 3.1 kg/m2, HbA1c 7.2 ± 1.0%) completed the study. Time spent with glucose levels in target range increased from 69.3 ± 12.3% at baseline to 85.0 ± 6.3% at 3 months in the AHCL group, while remaining unchanged in the control group (treatment effect 21.5% [95% CI 15.7, 27.3]; P < 0.001). The time with levels below range (<70 mg/dL) decreased from 8.7 ± 7.3% to 2.1 ± 1.7% in the AHCL group and remained unchanged in the MDI+BGM group (treatment effect -4.4% [95% CI -7.4, -2.1]; P < 0.001). Participants from the AHCL group also had significant improvements in HbA1c levels (treatment effect -0.6% [95% CI -0.9, -0.2]; P = 0.005) and in quality of life (QoL) in specific subscales compared with the MDI+BGM group. CONCLUSIONS: People with T1DM naive to CSII and CGM technologies initiating AHCL significantly and safely improved their glycemic control, as well as their QoL and psychological well-being.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc22-0470

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [7]MiniMed 780G, advanced hybrid closed loop system, 2021. Accessed 24 November 2021. Available from https://www.medtronic-diabetes.co.uk/insulin-pump-therapy/minimed-780g-system PMC12925981 41498529
  2. [17]Phillip M, Battelino T. The improvement in quality of life and life expectancy of people with diabetes increasingly depends on the success of innovative people in academia and industry to develop new technologies. Preface. Int J Clin Pract Suppl 2012; 175: 1 22308981

Cited by

Sorted by citations

Authors
Matejko, B., Juza, A., Kieć-Wilk, B., Cyranka, K., Krzyżowska, S., Chen, X., Cohen, O., Da Silva, J., Malecki, M. T., & Klupa, T.
Affiliations
  • Jagiellonian University (PL)
  • University of Rzeszów (PL)
  • 1Department of Metabolic Diseases, Jagiellonian University Medical College, Krakow, Poland
  • Szpital Uniwersytecki w Krakowie (PL)
  • 6Medtronic, Northridge, CA
  • Medtronic (Switzerland) (CH)
  • 7Medtronic International Trading Sàrl, Tolochenaz, Switzerland
Corresponding author
Klupa, Tomasz
Venue
Diabetes Care
Published
2022-08-15
Volume
45
Issue
11
Pages
2628-2635
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W4291972723
Cited by
72
References
30
Citations by year
2026: 10 · 2025: 14 · 2024: 19 · 2023: 26 · 2022: 3
FWCI
11.49
Type
journal article
Language
en
Open access
Locations
  • Diabetes Care (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Jagiellonian University Repository (Jagiellonian University) (submittedVersion, cc-by-nc-nd)
Funders
Medtronic (ERP-2019-12000)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, MiniMed 780G, advanced hybrid closed-loop system, insulin pump therapy, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, time in range, hypoglycemia, quality of life, adults with type 1 diabetes, diabetes technology adoption
MeSH terms
Adult, Blood Glucose, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Quality of Life, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review