Normalization of Glycemia in Diabetics During Meals with Insulin and Glucagon Delivery by the Artificial Pancreas
The DOI matches its Crossref record.
Abstract
An extracorporeal “closed-loop” system has been employed to maintain glycemia in the normal range during consumption of meals in nine insulin-treated diabetics. This artificial pancreas system incorporated continuous blopd glucose monitoring (0.05 ml. per minute, delay time 90 seconds), a computer programed to respond to glycemia, and a hormone delivery system. Intravenous insulin delivery rates were determined by control parameters responsive to both glucose concentration and its rate of change. Because insulin-dependent diabetics often defend themselves poorly against hypoglycemie (in some cases due to inadequate glucagon responses), the instrument was also programed for exogenous glucagon delivery. A priori selection of ideal parameters for insulin and glucagon delivery for each individual is not yet possible. Con sequently, when the parameters were used for the first time on each subject, they were varied over a reasonable range. This approach resulted in a corresponding variety of glycemie responses, the average of which characterized a set of initial parameters that is generally applicable. Appropriate control parameters are presented that successfully prevented hypoglycemie. Glucagon delivery directly related to glycemia appeared sufficient for this purpose, thus obviating the need for dextrose administration. This system provides a technique for complete normalization of blood glucose concentration in the types of diabetics tested, during both fed and interprandial periods. It has yielded insights essential to the development of more sophisticated future devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
“, adults) or specific subjects could be selected or the simulation could be run on the entire cohort; (3) selecting CGM sensor and insulin pump; and (4) selecting a set of outcome metrics.”
BackgroundContinuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
A semiclosed-loop algorithm for the control of blood glucose levels in diabetics
Fisher, M. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68209 · Cited by 271
El-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Slama, G., Klein, J.-C., Delage, A., Ardila, E., Lemaignen, H., Papoz, L., & Tchobroutsky, G. (1981) · Diabetes · doi:10.2337/diab.30.2.101 · Cited by 66
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
The metabolic response to glycemic control by the artificial pancreas in diabetic man
Zinman, B., Stokes, E. F., Albisser, A. M., Hanna, A. K., Minuk, H. L., Stein, A. N., Leibel, B. S., & Marliss, E. B. (1979) · Metabolism · doi:10.1016/0026-0495(79)90190-2 · Cited by 41
Self-citation
Metadata
- Authors
- Marliss, E. B., Murray, F. T., Stokes, E. F., Zinman, B., Nakhooda, A. F., Denoga, A., Leibel, B. S., & Albisser, A. M.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1977-07-01
- Volume
- 26
- Issue
- 7
- Pages
- 663-672
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W1993913148
- Cited by
- 70
- References
- 0
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.