CoChat

Relationship Between the Circadian Rhythms of Blood Pressure and Sympathovagal Balance in Diabetic Autonomic Neuropathy

Spallone, Vincenza, Bernardi, Luciano, Ricordi, Luigi, Soldà, Pierluigi, Maiello, Maria Rosaria, Calciati, Alessandro, Gambardella, Sergio, Fratino, Piero, Menzinger, Guido · 1993 · Diabetes
Cited by 135

The DOI matches its Crossref record.

Abstract

In diabetic autonomic neuropathy, abnormal circadian patterns of blood pressure and sympathovagal balance with reduced fall of blood pressure and prevalence of sympathetic activity during the night have been described. To correlate the abnormalities of blood pressure to those of sympathovagal balance, we simultaneously performed 24-h noninvasive monitoring of blood pressure and ECG in 25 diabetic patients (45.6 ± 13.6 yr of age with a 17.6 ± 9.1 yr duration of diabetes) with various degrees of cardiovascular reflex impairment. Autoregressive power spectrum analysis of RR interval variability was applied to 24-h ECG recordings to obtain for day and night periods the mean power of low- (0.03–0.15 Hz) and high-frequency (0.18–0.40 Hz) components, which are relative markers of sympathetic and vagal activity, respectively, and their ratio (low frequency/high frequency), assumed as index of sympathovagal balance. Diabetic patients showed a lower percentage of day-night change in systolic blood pressure (9 ± 5.48 vs. 11.6 ± 4.78%, P < 0.037), a lower day low frequency (5.9 ± 0.81 vs. 6.62 ± 0.73 In-ms2 P < 0.001), a lower night high frequency (6.06 ± 0.71 vs. 6.52 ± 0.85 In-ms2 P < 0.05), a lower day low frequency:high frequency ratio (1.82 ± 1.77 vs. 3.05 ± 1.82, P < 0.01), and a lower percentage of day-night change in low-frequency:high frequency ratio (– 13.4 ± 109.9 vs. 28.7 ± 29.7%, P < 0.05), when compared with control subjects. Day-night change in low frequency:high frequency ratio correlated to day-night change in systolic blood pressure (r = 0.52, P < 0.01) and diastolic blood pressure (r = 0.48, P < 0.015). In conclusion, in diabetic patients the degree of loss in day-night rhythm of blood pressure is associated with a proportional nocturnal sympathetic predominance. Decreased blood pressure fall combined with relative sympathetic prevalence during the night might represent a risk factor for cardiovascular accidents and could modify the circadian pattern of cardiovascular events in the diabetic population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.42.12.1745

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Spallone, V., Bernardi, L., Ricordi, L., Soldà, P., Maiello, M. R., Calciati, A., Gambardella, S., Fratino, P., & Menzinger, G.
Venue
Diabetes
Published
1993-12-01
Volume
42
Issue
12
Pages
1745-1752
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W4253209220
Cited by
135
References
0
FWCI
2.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.