CoChat

Validation of methods for measurement of insulin secretion in humans in vivo.

Open access
Kjems, L L, Christiansen, E, Vølund, A, Bergman, R N, Madsbad, S · 2000 · Diabetes
Cited by 80

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

To detect and understand the changes in beta-cell function in the pathogenesis of type 2 diabetes, an accurate and precise estimation of prehepatic insulin secretion rate (ISR) is essential. There are two common methods to assess ISR, the deconvolution method (by Eaton and Polonsky)-considered the "gold standard"-and the combined model (by Vølund et al.). The deconvolution method is a 2-day method, which generally requires separate assessment of C-peptide kinetics, whereas the combined model is a single-day method that uses insulin and C-peptide data from a single test of interest. The validity of these mathematical techniques for quantification of insulin secretion have been tested in dogs, but not in humans. In the present studies, we examined the validity of both methods to recover the known infusion rates of insulin and C-peptide mimicking ISR during an oral glucose tolerance test. ISR from both the combined model and the deconvolution method were accurate, i.e., recovery of true ISR was not significantly different from 100%. Furthermore, both maximal and total ISRs from the combined model were strongly correlated to those obtained by the deconvolution method (r = 0.89 and r = 0.82, respectively). These results indicate that both approaches provide accurate assessment of prehepatic ISRs in type 2 diabetic patients and control subjects. A simplified version of the deconvolution method based on standard kinetic parameters for C-peptide (Van Cauter et al.) was compared with the 2-day deconvolution method, and a close agreement was found for the results of an oral glucose tolerance test. We also studied whether C-peptide kinetics are influenced by somatostatin infusion. The decay curves after bolus injection of exogenous biosynthetic human C-peptide, the kinetic parameters, and the metabolic clearance rate were similar whether measured during constant peripheral somatostatin infusion or without somatostatin infusion. Assessment of C-peptide kinetics can be performed without infusion of somatostatin, because the endogenous insulin concentration remains constant. Assessment of C-peptide kinetics with and without infusion of somatostatin results in nearly identical secretion rates for insulin during an oral glucose tolerance test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diabetes.49.4.580

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 80

Metadata

Authors
Kjems, L. L., Christiansen, E., Vølund, A., Bergman, R. N., & Madsbad, S.
Venue
Diabetes
Published
2000-04-01
Volume
49
Issue
4
Pages
580-588
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2159047663
Cited by
80
References
9
FWCI
2.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of methods for measurement of insulin secretion in humans in vivo. https://app.cochat.ai/papers/10.2337/diabetes.49.4.580
The paper
Kjems, L. L., Christiansen, E., Vølund, A., Bergman, R. N., & Madsbad, S. (2000). Validation of methods for measurement of insulin secretion in humans in vivo. Diabetes. https://doi.org/10.2337/diabetes.49.4.580

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.