Continuous Glucose Monitoring in Interstitial Subcutaneous Adipose Tissue and Skeletal Muscle Reflects Excursions in Cerebral Cortex
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) is being explored using several types of glucose sensors. Some are designed for subcutaneous adipose tissue. It is important to determine to which extent these glucose fluctuations in different tissues reflect changes taking place in the central nervous system, where glucose sensing is thought to occur. We studied the ability of subcutaneous adipose interstitial fluid measurements to parallel glucose propagations in blood, muscle, and central nervous system (CNS) during hyper- and hypoglycemia. A subcutaneous CGM system was applied in the CNS, subcutaneous adipose tissue, and skeletal muscle of nine Vietnamese potbellied pigs, and data were compared with frequent sampling in blood. Alterations in glucose levels were induced with intravenous glucose and insulin. During hyperglycemia, no difference was detected in delay between blood and interstitial glucose levels in subcutaneous adipose tissue (18.0 ± 0.8 min), muscle (18.0 ± 0.9 min), and CNS (20.3 ± 1.2 min), respectively. During hypoglycemia, we found no time difference between interstitial parameters in the three tissues. However, the amplitude of glucose changes varied considerably, with a smaller magnitude of glucose change taking place in the brain. The timing of glucose excursions in subcutaneous adipose tissue and muscle reflect excursions in CNS. The reduced magnitude of glucose excursions in the brain suggests that different mechanisms of glucose transport are operative in CNS compared with subcutaneous adipose tissue and muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gudbjörnsdóttir, S., Sjöstrand, M., Strindberg, L., Wahren, J., & Lönnroth, P. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030434 · Cited by 98
Cited by
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Diabetes Mellitus and Blood-Brain Barrier Dysfunction: An Overview
Pooja Naik, L. C. (2014) · Journal of Pharmacovigilance · doi:10.4172/2329-6887.1000125 · Cited by 259
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Self-citationBarendse, S., Singh, H., Frier, B. M., & Speight, J. (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03416.x · Cited by 161
Metadata
- Authors
- Nielsen, J. K., Djurhuus, C. B., Gravholt, C. H., Carus, A. C., Granild-Jensen, J., Ørskov, H., & Christiansen, J. S.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2005-06-01
- Volume
- 54
- Issue
- 6
- Pages
- 1635-1639
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2116930722
- Cited by
- 53
- References
- 1
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring in Interstitial Subcutaneous Adipose Tissue and Skeletal Muscle Reflects Excursions in Cerebral Cortex. https://app.cochat.ai/papers/10.2337/diabetes.54.6.1635
- The paper
- Nielsen, J. K., Djurhuus, C. B., Gravholt, C. H., Carus, A. C., Granild-Jensen, J., Ørskov, H., & Christiansen, J. S. (2005). Continuous Glucose Monitoring in Interstitial Subcutaneous Adipose Tissue and Skeletal Muscle Reflects Excursions in Cerebral Cortex. Diabetes. https://doi.org/10.2337/diabetes.54.6.1635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.