Devices for Insulin Administration
The DOI matches its Crossref record.
Abstract
There is a significant need for revised, safe, and more effective insulin-delivery methods than subcutaneous injections in the treatment of both type I (insulindependent) and type II (non-insulin-dependent) diabetes. The aim of this review is to describe the rationale and methods for better use of injection and infusion devices for intensive insulin therapy and to describe results of animal and human research that will lead to an implantable artificial pancreas. Injection devices, e.g., jet injectors, insulin pens, and access ports, cannot be considered as a major breakthrough in the quest for improved control, although they may improve the patient's comfort. External pumps have benefits over multiple injections and conventional insulin therapy only in specific subgroups of patients, e.g., those with recurrent severe hypoglycemia, but only when used by experienced personnel. The external artificial pancreas (Biostator) is also to be used by experienced personnel for limited clinical and research applications, e.g., surgery of the diabetic patient. The development of an implantable version of the artificial pancreas is linked to progress in the field of reliable long-duration glucose sensors. Finally, programmable implantable insulin pumps, used as an open-loop delivery system, are the most promising alternative to intensive subcutaneous insulin strategies in the short term, although clear evidence of improved safety and efficacy remains to be documented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500
A critical review of mathematical models and data used in diabetology
Boutayeb, A., & Chetouani, A. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-43 · Cited by 126
Implantable insulin pumps. A position statement about their clinical use
Renard, E., & Schaepelynck-Bélicar, P. (2007) · Diabetes & Metabolism · doi:10.1016/j.diabet.2006.10.004 · Cited by 69
Burge, M. R., & Schade, D. S. (1997) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70268-1 · Cited by 48
Metadata
- Authors
- Selam, J.-L., & Charles, M. A.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1990-09-01
- Volume
- 13
- Issue
- 9
- Pages
- 955-979
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1978488317
- Cited by
- 90
- References
- 0
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Devices for Insulin Administration. https://app.cochat.ai/papers/10.2337/diacare.13.9.955
- The paper
- Selam, J.-L., & Charles, M. A. (1990). Devices for Insulin Administration. Diabetes Care. https://doi.org/10.2337/diacare.13.9.955
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.