CoChat

Clinical Trial of Programmable Implantable Insulin Pump For Type I Diabetes

Selam, Jean-Louis, Micossi, Piero, Dunn, Frederick L, Nathan, David M, Implantable Insulin Pump Trial Study Group · 1992 · Diabetes Care
Cited by 92

The DOI matches its Crossref record.

Abstract

Objective: The first step in the evolution of an artificial pancreas is the development of a reliable implantable pump for insulin delivery. Despite recent advances, significant issues remain, including small size of studies and frequent irreversible catheter obstructions. We report safety, feasibility, and efficacy results from 56 patients, representing 73 patient-yr of pump experience, entered into a multicenter trial with a new implantable programmable pump. Research Design and Methods: All patients had insulin-dependent (type 1) diabetes, were 38 ± 8 yr old, and were not prone to severe hypoglycemia. The pump (Infusaid 1000) has a pulsatile mechanism powered by freon-vapor pressure. Its rate is regulated by battery-powered valves, operated via a hand-held programmer. The pump is refilled transcutaneously with 25 ml U100 insulin (Hoechst 21PH) on a monthly basis and has a second septum (side port) proximal to the catheter, which allows flushing the catheter or lavaging the pump unit. The pumps were implanted after 3 mo intensive subcutaneous insulin therapy and catheters were positioned either in the peritoneum (i.p., n = 38) or the superior vena cava (i.v., n = 18). Results: All implanted pumps have functioned safely with no instance of overdelivery or stoppage. The most frequent complications were flow slow downs, presumably due to insulin precipitation within the pump, which occurred in 86% of pumps and were resolved in all but one case by lavaging the pump in situ with alkaline solution. Flow slow downs due to catheter obstruction occurred in 52% of the intravenous catheters but only 21% of the intraperitoneal catheters (P < 0.05) and were resolved in all but two cases by diluent flushing through the sideport. Incidence of severe hypoglycemia decreased from 0.47 before implant to 0.05 episodes/patient-yr after pump implantation (P < 0.001). Mean HbA1c fell from 7.4 ± 1.2% after intensive subcutaneous therapy to 7.1 ± 1.0% 12 mo after implantation. Only 2 patients withdrew from study after recurrent catheter problems, and quality-of-life questionnaires showed improvement in satisfaction with diabetes-specific quality of life when on implantable pump therapy. Conclusions: Insulin therapy with implantable pumps is effective and safe for periods up to 1.7 yr with a decreased risk of severe hypoglycemia than with intensive subcutaneous insulin therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.15.7.877

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
Selam, J.-L., Micossi, P., Dunn, F. L., Nathan, D. M., & Implantable Insulin Pump Trial Study Group
Venue
Diabetes Care
Published
1992-07-01
Volume
15
Issue
7
Pages
877-885
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2020745886
Cited by
92
References
0
FWCI
2.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Trial of Programmable Implantable Insulin Pump For Type I Diabetes. https://app.cochat.ai/papers/10.2337/diacare.15.7.877
The paper
Selam, J.-L., Micossi, P., Dunn, F. L., Nathan, D. M., & Implantable Insulin Pump Trial Study Group. (1992). Clinical Trial of Programmable Implantable Insulin Pump For Type I Diabetes. Diabetes Care. https://doi.org/10.2337/diacare.15.7.877

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.