CoChat

Unchanged Insulin Absorption After 4 Days' Use of Subcutaneous Indwelling Catheters for Insulin Injections

Hanas, S Ragnar, Carlsson, Sten, Frid, Anders, Ludvigsson, Johnny · 1997 · Diabetes Care
Cited by 28

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Since 1985, we have used indwelling catheters (Insuflon, Maersk Medical, Lynge, Denmark; Chronimed, Minnetonka, MN) to lessen pain when injecting insulin. However, some patients experience a rise in blood glucose after using indwelling catheters for a few days. We therefore studied the absorption of 125I-labeled insulin when using indwelling catheters. RESEARCH DESIGN AND METHODS: Five men and five women participated (age 18–25 years, C-peptide negative, HbA1c 9.0 ± 1.0% [mean ± SD, DCA-2000 method], diabetes duration 5–21 [median 9.5] years). After thyroid blockage with potassium iodide, we injected 5IU of 125I-labeled short-acting insulin subcutaneously in the abdomen (“ordinary injection”) and 5 IU on the contralateral side through an indwelling catheter (“catheter injection”). The injection/insertion area was free of lipohyper- and lipohypotrophies. Disappearance rate was measured for 180 min with a gamma camera. The patients injected all premeal injections of short-acting insulin through the same indwelling catheter in the following 4 days. The investigation procedure was repeated day 3 and 5. RESULTS: We found no statistically or clinically (95% CI) significant difference in residual activity of 125I-insulin after 60 min or in time for 50% of the injected depot to disappear (T-50%) among catheter injections on day 1, 3, and 5; ordinary injections on days 1, 3, and 5; or catheter and ordinary injections on days 1, 3, and 5, respectively. HbA1c correlated both to T-50% (r = 0.73, P = 0.016) and residual activity of 125I-insulin after 60 min (r = 0.69, P = 0.028), indicating that patients with a slower absorption will have a less ideal metabolic control when using premeal bolus injections. CONCLUSIONS: We conclude that using indwelling subcutaneous catheters for insulin injections for up to 4 days does not affect the absorption of short-acting insulin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.20.4.487

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hanas, S. R., Carlsson, S., Frid, A., & Ludvigsson, J.
Venue
Diabetes Care
Published
1997-04-01
Volume
20
Issue
4
Pages
487-490
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2068647881
Cited by
28
References
0
FWCI
0.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.