The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Rapid Changes in Postprandial Blood Glucose Produce Concentration Differences at Finger, Forearm, and Thigh Sampling Sites
Open accessAbstract
OBJECTIVE—To compare pre- and postmeal capillary blood glucose concentrations measured at the finger, forearm, and thigh in adults with diabetes. RESEARCH DESIGN AND METHODS—For phase 1, capillary blood glucose concentrations were measured at six time points (premeal and at ∼60, 90, 120, 150, and 180 min postmeal) using a blood glucose monitoring system and technician-obtained samples collected from finger, forearm, and thigh sites of 42 adults with diabetes. The finger samples were also tested with a laboratory instrument. For phase 2, ∼14 weeks later, the testing procedures were repeated with 38 subjects from the original study population. RESULTS—Meter finger results were accurate at all time points. Alternate sites tended to produce lower glucose readings compared to finger readings at times when glucose was increasing rapidly (60 and 90 min postmeal). Forearm-to-finger differences correlated with rates of glucose change (r = 0.56, P < 0.001), as did the thigh-to-finger differences (r = 0.52, P < 0.001). Other factors, such as subject age, BMI, diabetes type, and insulin dependence did not have a significant impact on site differences. When the testing procedures were repeated with the same subjects, the pattern of site differences was consistent, although individual results were variable. CONCLUSIONS—Changes in blood glucose immediately after a meal may be identified at finger sites before detection at forearm or thigh sites. Alternate site testing appears to be a useful option for routine self-monitoring before meals; however, patients and clinicians should recognize that results may be different from fingertip results when glucose levels are changing rapidly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When glucose concentrations are rising or have just risen sharply, fingertip capillary glucose concentrations are greater than those in capillary blood from other sites including forearm, thigh and abdomen (Ellison et al. 2002;Jungheim & Koschinsky, 2002;van der Valk et al. 2002), with variable differences in repeated tests on the same subject (Ellison et al. 2002);”
From Glycaemic index methodology (2005) · cites this paper as Ellison et al. 2002
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The anatomical site from which skin puncture samples are obtained influences results: Use of blood from so-called alternate sites (such as forearm or thigh rather than fingertip) for testing may exhibit a temporal lag between the circulating and measured concentrations of glucose when blood glucose is changing in vivo (117).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [117]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Louie, R. F., Tang, Z., Sutton, D. V., Lee, J. H., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-0257-pocgt · Cited by 178
Kuwa, K., Nakayama, T., Hoshino, T., & Tominaga, M. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00426-0 · Cited by 142
Tanizawa, Y., Matsuda, K., Matsuo, M., Ohta, Y., Ochi, N., Adachi, M., Koga, M., Mizuno, S., Kajita, M., Tanaka, Y., et al. (2000) · Diabetes · doi:10.2337/diabetes.49.1.114 · Cited by 66
Differences between capillary and venous blood glucose during oral glucose tolerance tests
Larsson-Cohn, U. (1976) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517609081941 · Cited by 65
Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm
Jungheim, K., & Koschinsky, T. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1303-a · Cited by 62
Use of an Automated Device for Alternative Site Blood Glucose Monitoring
Fineberg, S. E., Bergenstal, R. M., Bernstein, R. M., Laffel, L. M., & Schwartz, S. L. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1217 · Cited by 59
High Incidence of Maternal Transmission of Diabetes in Obese Uruguayan Children
Pisabarro, R., Recalde, A., & Chaftare, Y. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1303 · Cited by 38
Capillary-venous differences in blood glucose values during the oral glucose tolerance test.
Eriksson, K. F., Fex, G., & Trell, E. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.5.993a · Cited by 23
Response to Jungheim and Koschinsky
McGarraugh, G. (2001) · Diabetes Care · doi:10.2337/diacare.24.7.1304 · Cited by 20
Cited by
Sorted by citations
Items 101–133 of 133
Dukes, J. W., Chen, A. C., & Jovanovic, L. G. (2004) · Humana Press eBooks · doi:10.1007/978-1-59259-787-1_17 · Cited by 3
Postprandial glycemic effect of mulberry leaf extract: a randomized crossover pilot study in Asians
Lee, C. L., Chee, W. S. S., Lee, Y. Y., Singh, H. K. G., & Misra, S. (2025) · Nutrition & Food Science · doi:10.1108/nfs-09-2024-0299 · Cited by 2
Arimoto, K., Sasaki, H., Ogawa, K., Yamasaki, H., Okamoto, K., Furuta, H., Hanabusa, T., Nishi, M., Nakao, T., & Nanjo, K. (2004) · Diabetes Care · doi:10.2337/diacare.27.6.1449 · Cited by 2
Analysis: Glucose Testing of Blood Samples from Alternate Sites—State of Affairs
Peled, N. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.609 · Cited by 2
EFECTOS DE UNA INTERVENCIÓN PSICOLÓGICA EN LOS NIVELES DE GLUCOSA EN PACIENTES CON DIABETES TIPO 2
Campuzano, M. D. L. R., Rodríguez, J. C. G., Rodríguez, A. R., & Quiroz, C. N. N. (2013) · Revista Electrónica de Psicología Iztacala · Cited by 2
Treatment of Type 1 Diabetes Mellitus in Adults
Retnakaran, R. R., & Zinman, B. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-5583-9.00045-9 · Cited by 2
Frontal Regulation of Blood Glucose Levels as a Function of Hostility
Walters, R. P. (2005) · Cited by 2
Cai, Q., Zhao, P., Chen, X., Yu, S., Guo, L., & Pan, Q. (2025) · Aging Medicine · doi:10.1002/agm2.70044 · Cited by 3
Deza, S., Fernández-Montero, A., Calleja, S., Zabalza, N., Arias, M. Á., Gómez, C., Orbegozo, N., Fischer, T., Engelmann-Wadin, S., Blumhardt, P., et al. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0671 · Cited by 1
Contrôle biologique de l’entraînement sportif par spectrométrie IR-TF
Boussaidi, L., Cazorla, G., Guezennec, C. Y., Fontand, E., & Burnat, P. (2008) · Science & Sports · doi:10.1016/j.scispo.2008.03.004 · Cited by 1
Treatment of Type 1 Diabetes Mellitus in Adults
Retnakaran, R. R., & Zinman, B. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-18907-1.00044-5 · Cited by 1
Equivalence of Fasting and Non-Fasting Blood Glucose Readings at the Palm and Fingertip Sites
Owida, H. A., Al-Nabulsi, J., & Khatib, A. O. A. (2022) · International Conference on Information and Communication Systems (ICICS) · doi:10.1109/icics55353.2022.9811230 · Cited by 1
Automonitoraggio glicemico nei pazienti diabetici
Montagnana, M., & Lippi, G. (2013) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-013-0017-z · Cited by 1
A PRACTICAL NONINVASIVE BLOOD GLUCOSE MEASUREMENT SYSTEM USING NEAR-INFRARED SENSORS
Taghizadeh-Behbahani, R., Boostani, R., & Yazdi, M. (2021) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s101623722150040x · Cited by 1
Vincze, G., & Parthan, A. (2004) · Journal of Pharmacy Practice · doi:10.1177/0897190004264815 · Cited by 1
Cribado de diabetes mellitus tipo 2: algo más que la búsqueda de la diabetes ignorada
González-Clemente, J. M. (2004) · Medicina Clínica · doi:10.1016/s0025-7753(04)74451-6 · Cited by 1
Muestra de sangre capilar para el cribado de la diabetes mellitus tipo 2: dedo frente a antebrazo
Fernández, F. J. C., Girón, M. J. I., de Segura, I. L. G., & Aguirre‐Jaime, A. (2004) · Medicina Clínica · doi:10.1016/s0025-7753(04)74452-8 · Cited by 1
Analysis: Glucose Monitoring and Physical Activity: The Present and Future Challenges
Colberg, S. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.681 · Cited by 1
Clinical Usefulness of Glucose Testing from the Forearm in Diabetic Patients
Lee, S.-W., Chon, S., Oh, S., Woo, J., Kim, S. W., Kim, J. W., Kim, Y. S., Paeng, J. R., Koh, G., & Nam, H. H. (2006) · Journal of Korean Endocrine Society · doi:10.3803/jkes.2006.21.4.281 · Cited by 1
Insulin, glucagon, and hypoglycemic drugs
Krans, H. M. J. (2003) · Side effects of drugs annual · doi:10.1016/s0378-6080(03)80049-1 · Cited by 1
Seley, J. J. (2003) · AJN American Journal of Nursing · doi:10.1097/00000446-200303000-00037 · Cited by 1
Metabolic Control Targets for Patients with Type 1 Diabetes in Clinical Practice
María, G., López‐Tinoco, C., Ortego-Rojo, J., & Aguilar‐Diosdado, M. (2011) · InTech eBooks · doi:10.5772/17792
Mansell, K. D., Blackburn, D. F., & Eurich, D. T. (2009) · Canadian Pharmacists Journal / Revue des Pharmaciens du Canada · doi:10.3821/1913-701x-142.6.298
Surveillance du contrôle de la glycémie
Berard, L., Blumer, I. R., Houlden, R. L., Miller, D. B., & Woo, V. C. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.07.037
Medical Management of Preexisting Diabetes in Pregnancy
Trujillo, A. L., Wright, L. A.-C., & Jovanovic, L. G. (2009) · Humana Press eBooks · doi:10.1007/978-1-60327-250-6_17
Parkin, C. G. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700420
Sajjadi, M., Bijari, H., Soltani, M., & Kianmehr, M. (2017) · Quarterly of Horizon of Medical Sciences · doi:10.18869/acadpub.hms.23.1.1
Alternate site testing for diabetes self-care
Miller, V. (2021) · Nursing Made Incredibly Easy! · doi:10.1097/01.nme.0000767272.59341.14 · Cited by 1
Insulin, glucagon, and hypoglycemic drugs
Krans, H. M. J. (2004) · Side effects of drugs annual · doi:10.1016/s0378-6080(04)80049-7
INSULINS AND OTHER HYPOGLYCEMIC DRUGS
(2009) · Elsevier eBooks · doi:10.1016/b978-0-444-53271-8.50008-9
(2006) · Elsevier eBooks · doi:10.1016/b0-44-451005-2/00983-9
(2015) · Elsevier eBooks · doi:10.1016/b978-0-444-53717-1.00395-4
Doi, H., Irie, T., Takenaka, K., Adachi, S., Sakazume, T., Kato, T., & Ito, H. (2026) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632261454296
Metadata
- Authors
- Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L.
- Affiliations
- LifeScan, Milpitas, California
- ORCID
- Horwitz, David L.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2002-06-01
- Volume
- 25
- Issue
- 6
- Pages
- 961-964
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2154078343
- Semantic Scholar
- e98ef81443d8253dc4e47cf37f2bfa46dd424c26
- Cited by
- 133
- References
- 12
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 6 · 2018: 4 · 2017: 3 · 2016: 3 · 2015: 5 · 2014: 1 · 2013: 9 · 2012: 4
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Diabetes Association
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- postprandial blood glucose, capillary blood glucose, forearm, thigh, self-monitoring of blood glucose, meter accuracy, diabetes mellitus
- MeSH terms
- Adult, Blood Glucose, Blood Specimen Collection, Capillaries, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Fingers, Forearm, Humans, Leg, Male, Middle Aged, Regression Analysis, Time Factors, Blood Glucose Self-Monitoring, Reproducibility of Results, Postprandial Period
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review