The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
A Randomized, Prospective Trial Comparing the Efficacy of Continuous Subcutaneous Insulin Infusion With Multiple Daily Injections Using Insulin Glargine
Open accessAbstract
OBJECTIVE—The efficacy of the insulin analogs now available for multiple daily injection (MDI) and continuous subcutaneous insulin infusion (CSII) therapy in type 1 diabetes has not yet been established in pediatric patients. Our principal aim in this short-term study was to compare the efficacy of CSII to MDI with glargine in lowering HbA1c levels in children and adolescents with type 1 diabetes. RESEARCH DESIGN AND METHODS—Thirty-two youth with type 1 diabetes (age 8–21 years) were randomly assigned to receive either MDI treatment with once-daily glargine and premeal/snack insulin aspart or CSII with insulin aspart. Dose titration in both groups was based on home self-monitored blood glucose measurements and monthly HbA1c. HbA1c, total daily insulin dose (TDD), self-monitored blood glucose readings, and adverse events were compared after 16 weeks of therapy. RESULTS—While there was no significant change in the glargine group (HbA1c 8.2% at baseline vs. 8.1% at 16 weeks), youth randomized to CSII had a sharp reduction in HbA1c levels, from 8.1 to 7.2% after 16 weeks of therapy (P < 0.02 vs. baseline and <0.05 vs. glargine group). TDD was unchanged in the glargine group, but significantly dropped with CSII (1.4 units/kg at baseline vs. 0.9 units/kg at 16 weeks, P < 0.01). Both groups had similar basal doses and insulin-to-carbohydrate ratios. Fasting self-monitored blood glucose was similar in both groups, but lunch, dinner, and bedtime readings were significantly lower in the CSII group (P < 0.01). CONCLUSIONS—Lower HbA1c and premeal glucose levels were more achievable in this short-term study with CSII than with glargine-based MDI treatment. CSII is an efficacious treatment to improve metabolic control in youth with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, RCTs that compared insulin pumps and MDI with rapidacting insulin analogs demonstrated a modest improvement in A1C levels in participants on insulin pump therapy (178,179).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [178]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Lepore, M., Pampanelli, S., Fanelli, C., Porcellati, F., Bartocci, L., Di Vincenzo, A., Cordoni, C., Costa, E., Brunetti, P., & Bolli, G. B. (2000) · Diabetes · doi:10.2337/diabetes.49.12.2142 · Cited by 818
Standards of Medical Care for Patients With Diabetes Mellitus
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s33 · Cited by 614
Boland, E. A., Grey, M. J., Oesterle, A., Fredrickson, L. P., & Tamborlane, W. V. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1779 · Cited by 430
Self-citationA Modified Quality-of-Life Measure for Youths: Psychometric Properties
Ingersoll, G. M., & Marrero, D. G. (1991) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572179101700219 · Cited by 325
Weintrob, N., Benzaquen, H., Galatzer, A., Shalitin, S., Lazar, L., Fayman, G., Lilos, P., Dickerman, Z., & Phillip, M. (2003) · PEDIATRICS · doi:10.1542/peds.112.3.559 · Cited by 236
Safety and effectiveness of insulin pump therapy in children and adolescents with type 1 diabetes
Plotnick, L. P., Clark, L. M., Brancati, F. L., & Erlinger, T. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1142 · Cited by 216
Ramsey, B. W., & Boat, T. F. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70301-9 · Cited by 200
Ahern, J. A., Boland, E. A., Doane, R., Ahern, J. J., Rose, P., Vincent, M., & Tamborlane, W. V. (2002) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2002.30103.x · Cited by 174
Self-citation
Cited by
Sorted by citations
Items 201–300 of 373
Fisher, L. K. (2006) · Pediatric Diabetes · doi:10.1111/j.1399-543x.2006.00173.x · Cited by 13
From pumps to prevention: recent advances in the treatment of type 1 diabetes
Sherr, J. L., Cengiz, E., & Tamborlane, W. V. (2009) · Drug Discovery Today · doi:10.1016/j.drudis.2009.06.011 · Cited by 15
Self-citationHuo, L., Deng, W., Lan, L., Li, W., Shaw, J. E., Magliano, D. J., & Ji, L. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.891718 · Cited by 12
“The advantage of pump therapy over MDI have been demonstrated even when MDI includes a long acting insulin analog (glargine) (5, 6).”
BackgroundKaria, D., Nambiar, R., & Arora, M. (2019) · Proceedings of the ... International Conference on Engineering Design · doi:10.1017/dsi.2019.89 · Cited by 12
“Numerous additional studies have extensively documented the benefits of CSII over MDI as an insulin therapy for T1DM patients (Doyle et al., 2004, Retnakaran et al., 2004).”
BackgroundABCD position paper on insulin pumps
Hammond, P. J., Boardman, S., & Greenwood, R. (2006) · Practical Diabetes · doi:10.1002/pdi.1023 · Cited by 12
Factors associated with basal insulin dose in Japanese children and young adult type 1 diabetics
Hashimoto, T., Kawamura, T., Kashihara, Y., Hirose, M., Higashide, T., Tsuruhara, A., Fujimoto, H., Noi, K., & Shintaku, H. (2011) · Journal of Diabetes Investigation · doi:10.1111/j.2040-1124.2011.00171.x · Cited by 11
“Doyle et al.(10) reported that the mean BT ratio was 0.”
BackgroundInfluentialInsulin pump therapy guidelines for China (July 2010)
Mu, Y., & Yin, S. (2011) · Journal of Diabetes · doi:10.1111/j.1753-0407.2011.00174.x · Cited by 11
Optimal Control of Blood Glucose: The Diabetic Patient or the Machine?
Brown, L. R., & Edelman, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001083 · Cited by 13
Ramchandani, N., Ellis, M. K., Jain, S., Bhandari, S., Anhalt, H., Maclaren, N. K., & Ten, S. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400315 · Cited by 11
Bénéfices de l’insulinothérapie par pompe chez les enfants diabétiques de type 1
Hasselmann, C., Bonnemaison, É., Faure, N., Mercat, I., Pépin-Donat, M., Magontier, N., Chantepie, A., & Labarthe, F. (2012) · Archives de Pédiatrie · doi:10.1016/j.arcped.2012.03.051 · Cited by 11
Nuboer, R., & Bruining, G. J. (2006) · Pediatric Diabetes · doi:10.1111/j.1399-543x.2006.00168.x · Cited by 11
Merheb, M. T., Chaiban, J. T., Salti, I., Sammak, R., Choucair, M., & Nasrallah, M. (2019) · International Journal of Diabetes and Metabolism · doi:10.1159/000497653 · Cited by 11
“4 (14-44) 18 (2-28) 12 11 10 9 8 7 6 5 4 3 2 1 M e a n H b A 1 c ( % ) 10”
BackgroundInfluentialde la Fuente, J. S., Berná, V. G., Piquero, J. M. F., Zanuy, M. Á. V., & López-Coterilla, A. H. D. T. (2008) · Revista Clínica Española · doi:10.1157/13115203 · Cited by 12
Gangqiang, G., Chen, H., & Sun, H. (2024) · Journal of Clinical Nursing · doi:10.1111/jocn.17110 · Cited by 10
Almasi, S., Aliparasti, M. R., Aliasgarzadeh, A., Abd‐Nikfarjam, B., Hyöty, H., Knip, M., Feizi, H., Sioofy‐Khojine, A., & Rahnama, B. (2015) · Immunology Letters · doi:10.1016/j.imlet.2015.05.021 · Cited by 10
Moreno-Fernández, J., Gómez, F. J., Gazquez, M., Pedroche, M., García‐Manzanares, Á., Tenías, J. M., Benito, P., & Gomez, I. R. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0033 · Cited by 10
Blair, J., Gregory, J. W., Hughes, D. A., Ridyard, C. H., Gamble, C. L., McKay, A., Didi, M., Thornborough, K., Bedson, E., Awoyale, L., et al. (2015) · Trials · doi:10.1186/s13063-015-0658-5 · Cited by 10
“In other studies the observation period (4 to 6 months) may be too brief to show patient fatigue in the use of this intensive therapy [20,24-26].”
BackgroundUpdate on Preventive Cardiology
Clauss, S. B., & de Ferranti, S. D. (2020) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2020.06.006 · Cited by 10
KANAZAWA, Y., Igarashi, Y., Komiya, K., Sakurai, Y., Shimizu, T., Fujitani, Y., Tanaka, Y., Watada, H., Kawamori, R., & Hirose, T. (2007) · Endocrine Journal · doi:10.1507/endocrj.k07e-035 · Cited by 10
Future Developments in Insulin Pump Therapy
Fisher, L. K., & Halvorson, M. (2006) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721705285644 · Cited by 10
“However, studies have shown that pump therapy has the ability to improve glycemic control and reduce the development of hypoglycemia in pediatric patients with diabetes.(2-8)”
BackgroundDiversity in diabetes: the role of insulin aspart
Heller, S. R., McCance, D. R., Moghissi, E. S., Nazeri, A., & Kordonouri, O. (2011) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.1240 · Cited by 9
“A second 16-week, open-label, randomized, parallelgroup study in 32 children and adolescents with type 1 diabetes demonstrated better glycaemic control with insulin aspart CSII than with insulin aspart plus insulin glargine basal–bolus treatment, but both regimens were similarly well tolerated (Table 1) [26].”
BackgroundQuirós, C., Patrascioiu, I., Giménez, M., Vinagre, I., Vidal, M., Jansà, M., & Conget, I. (2014) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2014.01.003 · Cited by 9
Bashan, E., & Hodish, I. (2012) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2012.03.012 · Cited by 9
Moreno-Fernández, J., Chico, A. I., Martínez‐Brocca, M. A., Beato-Víbora, P. I., Vidal, M., de la Piedra, M. A. C., Quirós, C., Muñoz‐Rodríguez, J. R., SPAIP Registry Study, López, A. A., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0207 · Cited by 10
“2,3 In fact, an additional HbA1c reduction of 5 mmol/mol (0.4”
InfluentialKaragüzel, G., Satılmış, A., Akçurin, S., & Bircan, İ. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.03.007 · Cited by 9
Cogen, F. R., Henderson, C. L., Hansen, J. A., & Streisand, R. M. (2007) · Clinical Pediatrics · doi:10.1177/0009922807303224 · Cited by 9
Sharma, D., Mathur, S., Sharma, B., & Saran, S. (2014) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.129714 · Cited by 9
Counterpoint: Are Insulin Pumps Underutilized in Type 1 Diabetes? No
Schade, D. S., & Valentine, V. (2006) · Diabetes Care · doi:10.2337/dc06-0468 · Cited by 9
“The first trial was performed in youths aged 8–21 years and lasted 4 months (12).”
BackgroundBasal insulin requirement of youth with type 1 diabetes differs according to age
Urakami, T., Kuwabara, R., Habu, M., Okuno, M., Suzuki, J., & Takahashi, S. (2013) · Journal of Diabetes Investigation · doi:10.1111/jdi.12161 · Cited by 8
Quand et comment traiter un patient diabétique par pompe à insuline externe ?
Clavel, S., Guerci, B., Hanaire, H. P., Lassmann-Vague, V., Leroy, R., Loeuille, G., Mantovani, I., Pinget, M., Renard, É., & Tubiana‐Rufi, N. (2009) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(09)71649-9 · Cited by 8
Moreno-Fernández, J., López, L. M., Gómez, F. J., Pinés, P. J., Blanco, B., González, J., López, J., Herránz, S., Roa, C., & Romero, F. J. G. (2020) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2019.10.011 · Cited by 8
Sperling, M. A., Wolfsdorf, J. I., Menon, R. K., Tamborlane, W. V., Maahs, D. M., Battelino, T., & Phillip, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-62520-3.00021-x · Cited by 11
Self-citationZahedifar, R., & Khalaji, A. K. (2022) · Scientific Reports · doi:10.1038/s41598-022-16535-2 · Cited by 9
Gao, G.-Q., Dong, Q.-Y., Li, S.-J., Zhang, Y., Li, W., Du, W., Liang, C., & Wang, Y.-L. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0109 · Cited by 8
“8,11 A study by Torres et al. 12 showed that compared with treatment with insulin glargine once daily and more than three times the amount of preprandial insulin lispro, the requirement of insulin was significantly decreased in type 1 diabetes patients treated with CSII (0.75 – 0.21IU/kg/day vs.…”
InfluentialClissold (2007) · Core evidence · doi:10.2147/ce.s7422 · Cited by 9
“In clinical trials a number of authors commented on the positive impact of insulin glargine on patient wellbeing and its acceptance by patients (Schober et al. 2002; Doyle et al. 2004; Colino et al. 2005; Herman et al. 2005; Home et al. 2005; Bretzel et al. 2006; Eliaschewitz et al. 2006; Meneghini et al. 2006; Chater…”
García, L. P., Iriarte, M. J. G., & Mouriz, M. G. (2015) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2015.06.003 · Cited by 8
Yang, H., Heng, X., Liang, C., Liu, X., Du, W., Li, S., Wang, Y., Dong, Q., Li, W., Pan, Z., et al. (2014) · Journal of International Medical Research · doi:10.1177/0300060514533523 · Cited by 8
NICE guidance on insulin pump therapy: time for a re-appraisal?
Hammond, P. J. (2005) · Practical Diabetes · doi:10.1002/pdi.774 · Cited by 8
Rendell, S., Kosoko-Lasaki, O., Penny, G., Cook, C. T., Sharma, A., Austin, W. P., & Rendell, M. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700235 · Cited by 7
Kanungo, A., Jhingan, A. K., Rn, S., Muruganathan, A., & Das, A. K. (2014) · PubMed · Cited by 7
Yuan, G., Jia, J., Zhang, C., Yu, S., Dong, S., Ye, J., Zhu, T., Tang, B., Qian, W., Wang, D., et al. (2014) · Endocrine Journal · doi:10.1507/endocrj.ej13-0483 · Cited by 7
“Short-term studies with CSII showed that CSII compared with MDI is a more efficient method of improving prompt glucose control and it does not lead to the increase in the insulin dosage [17, 18].”
BackgroundQuirós, C., Patrascioiu, I., Giménez, M., Vinagre, I., Vidal, M., Jansà, M., & Conget, I. (2014) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2014.06.003 · Cited by 7
Association of CTLA-4 Polymorphisms with Type 1 Diabetes in the Egyptian Population
Koeleman, H. M. S. B. (2013) · Journal of Diabetes & Metabolism · doi:10.4172/2155-6156.1000291 · Cited by 8
“5 % [32,33].”
Achievement of metabolic control among children and adolescents with type 1 diabetes in Spain
Rica, I., Delgado, A. M., Gómez-Gila, A. L., Clemente, M., González, I. P., Caimari, M., Cuartero, B. G., & Barrio, R. (2017) · Acta Diabetologica · doi:10.1007/s00592-017-0991-0 · Cited by 7
Type 1 Diabetes in Children and Adolescents
Sikes, K. A., Name, M. A. V., & Tamborlane, W. V. (2018) · Springer eBooks · doi:10.1007/978-3-319-73782-9_31 · Cited by 7
Self-citationPawliński, Ł., Gastoł, J., Fiema, M., Matejko, B., & Kieć‐Wilk, B. (2019) · Endokrynologia Polska · doi:10.5603/ep.a2019.0011 · Cited by 6
“such as a better glycaemic level or lipid profile [13].”
BackgroundAn overview of insulin pump therapy: appropriate use of an expensive resource
Brown, V. (2012) · Journal of Endocrinology Metabolism and Diabetes of South Africa · doi:10.1080/22201009.2012.10872290 · Cited by 6
Experiences of patients with insulin‐treated diabetes in conscript military service
Sane, T., Rautuoja, A., Mäkelä, M., Westerberg, J., & Lehesjoki, M. (2007) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02021.x · Cited by 6
Insulin Pump Class: Back to the Basics of Pump Therapy
Reece, S. W., & Williams, C. L. H. (2014) · Diabetes Spectrum · doi:10.2337/diaspect.27.2.135 · Cited by 6
Demir, G., Altınok, Y. A., Özen, S., Darcan, Ş., & Gökşen, D. (2020) · Journal of Clinical Research in Pediatric Endocrinology · doi:10.4274/jcrpe.galenos.2020.2020.0171 · Cited by 6
Schade, D. S., & Wolpert, H. A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.845 · Cited by 6
High precision innovative micropump for artificial pancreas
Chappel, E., Mefti, S., Lettieri, G.-L., Proennecke, S., & Conan, C. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2036068 · Cited by 6
“INTRODUCTION Since the first human trials of insulin subcutaneous delivery with a pump [1], it has been shown that the insulin pump therapy reduces the number and the incidence of hypoglycemic events for patients with type 1 diabetes mellitus [2-4].”
BackgroundGlycemic Treatment in Type 1 and Type 2 Diabetes
Bloomgarden, Z. T. (2006) · Diabetes Care · doi:10.2337/dc06-zb11 · Cited by 6
García, L. P., Iriarte, M. J. G., & Mouriz, M. G. (2015) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2015.09.001 · Cited by 5
Campbell, F. (2008) · The British Journal of Diabetes · doi:10.1177/1474651408098138 · Cited by 5
Perceptions in Type 1 Diabetes Mellitus with or Without the Use of Insulin Pump: An Online Study
Benioudakis, E. S. (2019) · Current Diabetes Reviews · doi:10.2174/1573399815666190502115754 · Cited by 5
Moreno-Fernández, J., Pazos-Couselo, M., González‐Rodríguez, M., Rozas, P., Delgado‐Rodríguez, M., Aguirre, M., & López, J. M. G. (2018) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2018.11.003 · Cited by 5
O’Connell, M. A., & Cameron, F. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200113 · Cited by 5
Acute complications of insulin pump therapy
Guerci, B. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(06)70009-2 · Cited by 6
Moreno-Fernández, J., Gómez, F. J., Moreno, M. Á. G., & Castano, J. P. (2016) · Journal of Diabetes Research · doi:10.1155/2016/4171789 · Cited by 5
Sperling, M. A., WEINZIMER, S. A., & Tamborlane, W. V. (2008) · Elsevier eBooks · doi:10.1016/b978-141604090-3.50015-6 · Cited by 5
Self-citationTreatment of type 1 diabetes in children and adolescents
Desmangles, J. (2008) · Drug Development Research · doi:10.1002/ddr.20241 · Cited by 5
“Others have reported that patient receiving CSII were better able to cope with their disease [Doyle et al. 2004] and had higher treatment satisfaction [Weintrob et al., 2003] and significantly better ratings of quality of life when compared with patients receiving MDI [Cogen et al., 2007].”
BackgroundResultAchieving effective glycaemic control using an insulin micro-pump
Kelly, P. (2017) · British Journal of Community Nursing · doi:10.12968/bjcn.2017.22.2.66 · Cited by 4
“In order to evaluate its effectiveness in terms of ameliorating blood glucose variability (BGV) and improving HbA1c.”
BackgroundInfluentialToth, G. H. (2005) · Paediatrics & Child Health · doi:10.1093/pch/10.1.28 · Cited by 4
Blair, J., Peak, M., & Gregory, J. W. (2011) · BMJ · doi:10.1136/bmj.d5221 · Cited by 4
Tenreiro, A. M. P., Villar‐Taibo, R., Pazos-Couselo, M., González‐Rodríguez, M., Casanueva, F. F., & López, J. M. G. (2012) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2012.02.005 · Cited by 4
Lichtenberger-Geslin, L., Boudailliez, B., Braun, K., Bach, V., Mercier, A.-M., & Bony-Trifunovic, H. (2013) · Archives de Pédiatrie · doi:10.1016/j.arcped.2012.12.011 · Cited by 4
Tenreiro, A. M. P., Villar‐Taibo, R., Pazos-Couselo, M., González‐Rodríguez, M., Casanueva, F. F., & López, J. M. G. (2012) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2012.04.013 · Cited by 4
National Register of patients with insulin pump treatment in the Czech Republic
Jankovec, Z., Cechurová, D., Krčma, M., Lacigová, S., Žourek, M., & Rušavý, Z. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(06)70017-1 · Cited by 4
A new look at patient selection criteria for continuous subcutaneous insulin infusion (CSII)
Lenhard, M. J. (2006) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(06)70018-3 · Cited by 4
New Technologies for Glucose Monitoring and Insulin Administration
Horwitz, D. L., & Klonoff, D. C. (2016) · Wiley eBooks · doi:10.1002/9781118924853.ch30 · Cited by 4
Aziz, K. M. A., & Othman, A. (2020) · International Journal of Diabetology & Vascular Disease Research · doi:10.19070/2328-353x-2000015e · Cited by 3
Selma, B., Selma, B., Abouaïssa, H., Chouraqui, S., Kadem, H., Mehdeb, D., & Elaffifi, M. (2024) · Iran Journal of Computer Science · doi:10.1007/s42044-023-00170-9 · Cited by 3
“A detailed comparison of the effectiveness of the two therapies was carried out in [8, 9].”
Kesavadev, J., Jain, S. M., Muruganathan, A., & Das, A. K. (2014) · PubMed · Cited by 3
Use of new insulins in children
Regan, F. M., & Dunger, D. B. (2006) · Archives of Disease in Childhood Education & Practice · doi:10.1136/adc.2005.078188 · Cited by 3
Gabbay, M. A. L., & Dib, S. A. (2007) · Arquivos Brasileiros de Endocrinologia & Metabologia · doi:10.1590/s0004-27302007000700022 · Cited by 3
Evolving trends in insulin delivery in pursuit of improvements in diabetes management.
Akhrass, F., Skinner, N., Boswell, K. A., & Travis, L. B. (2010) · Europe PMC (PubMed Central) · Cited by 3
Hartemann, A., & Bourron, O. (2011) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(11)70244-9 · Cited by 3
Type 1 Diabetes in Children and Adolescents
Hu, P., Name, M. A. V., Stephenson, K., Sikes, K. A., & Tamborlane, W. V. (2024) · Springer eBooks · doi:10.1007/978-3-031-66296-6_30 · Cited by 3
Self-citationSoliman, A. T., Omar, M., Rizk, M. M., Awwa, A. E., & AlGhobashy, F. M. (2006) · Journal of Tropical Pediatrics · doi:10.1093/tropej/fmk005 · Cited by 3
Pramlintide in Pediatric Type 1 Diabetes
Fennoy, I. (2009) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.04.065 · Cited by 3
Is continuous subcutaneous insulin infusion still needed
Pickup, J. C. (2007) · Cited by 3
Predictors of the effectiveness of insulin pumps in patients with type 1 diabetes mellitus
Neves, J. C., Neves, C., Neves, C., & Carvalho, D. M. (2021) · Endocrine · doi:10.1007/s12020-021-02837-4 · Cited by 2
Diabetes Care and Education: A Look Backward and Forward
Siminerio, L. M., WANG, Y., & Charron‐Prochownik, D. (2025) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2025.21.1.5 · Cited by 5
Will Long Acting Insulin Analogs Influence the Use of Insulin Pump Therapy in Type 1 Diabetes?
DeVries, J. H. (2005) · Current Diabetes Reviews · doi:10.2174/1573399052952659 · Cited by 2
“Doyle et al. performed a randomized clinical trial in 32 adolescents, age range 8-21 yrs, mean 12.5 ± 3.2 and 13 ± 2.8 in the insulin pump and injection group, respectively [ 31 ].”
MethodInfluentialInsulin Requirements in Relation to Insulin Pump Indications in Type 1 Diabetes
GHIMPEŢEANU, G., Iancu, S., Román, G., & Alionescu, A. (2015) · Notulae Scientia Biologicae · doi:10.15835/nsb.7.3.9653 · Cited by 2
Continuous subcutaneous insulin infusion: experience from a large specialist service
Chellamuthu, P., Lawrence, I., Kitchener, D. L., McNally, P. G., Gregory, R., Jackson, S., Kong, M., Jarvis, J., & Davies, M. J. (2009) · Practical Diabetes · doi:10.1002/pdi.1337 · Cited by 2
Insulin, other hypoglycemic drugs, and glucagon
Page, R. C. (2010) · Side effects of drugs annual · doi:10.1016/s0378-6080(10)32042-3 · Cited by 2
Les nouvelles insulines: intérêts et inconvénients
Sola‐Gazagnes, A., Larger, É., M’Bemba, J., Elgrably, F., & Slama, G. (2006) · Réanimation · doi:10.1016/j.reaurg.2006.09.009 · Cited by 2
Myneni, A., Aldasouqi, S. A., Page, C., Weller, L., Carella, M. J., & Gossain, V. V. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300225 · Cited by 2
L’insulinothérapie en pédiatrie
Beltrand, J., & Robert, J. (2013) · Archives de Pédiatrie · doi:10.1016/s0929-693x(13)71427-1 · Cited by 2
Childhood Obesity and Juvenile Diabetes
Knip, M. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374995-6.10027-1 · Cited by 2
Lassmann-Vague, V., Clavel, S., Guerci, B., Hanaire, H. P., Leroy, R., Mantovani, I., Pinget, M., Renard, É., & Tubiana‐Rufi, N. (2010) · Cited by 2
Aktueller Stand der klassischen Insulinpumpentherapie
Siegmund, T., & Thomas, A. (2017) · Der Diabetologe · doi:10.1007/s11428-017-0205-y · Cited by 2
Manousaki, D., Deladoëy, J., Geoffroy, L., & Olivier, P. (2017) · Frontiers in Endocrinology · doi:10.3389/fendo.2017.00084 · Cited by 2
Therapy of Type 1 Diabetes Mellitus
Cohan, P., & Peters, A. L. (2009) · Springer eBooks · doi:10.1007/978-0-387-09841-8_43 · Cited by 2
Kerr, D. E. (2008) · The British Journal of Diabetes · doi:10.1177/1474651408097727 · Cited by 2
Feasibility of Induced Pluripotent Stem Cell Therapies for Treatment of Type 1 Diabetes
Duffy, C. D., Prugue, C., Glew, R., Smith, T., Howell, C., Choi, G., & Cook, A. D. (2018) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2018.0124 · Cited by 3
“11 Because of their ease of use, many individuals use insulin pumps to replace insulin injections, although insulin pumps only marginally improve blood glucose levels.”
New Technologies for Insulin Administration and Glucose Monitoring
Wolpert, H. A., & Shih, J. L. (2010) · Wiley eBooks · doi:10.1002/9781444324808.ch28 · Cited by 2
A Review of the Management of Implanted Medical Devices for Diabetes: Trends and Directions
Edman, C. F., & Drinan, D. D. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200609 · Cited by 2
Metadata
- Authors
- Doyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V.
- Affiliations
- From the Department of Pediatrics and the Children’s Clinical Research Center, Yale University School of Medicine, New Haven, Connecticut
- Yale University (US)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2004-07-01
- Volume
- 27
- Issue
- 7
- Pages
- 1554-1558
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2138976255
- Cited by
- 373
- References
- 15
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 6 · 2023: 2 · 2022: 9 · 2021: 8 · 2020: 10 · 2019: 13 · 2018: 14 · 2017: 9 · 2016: 15 · 2015: 19 · 2014: 24 · 2013: 20 · 2012: 23
- FWCI
- 17.43
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Yale University
- Novo Nordisk
- National Institutes of Health (5u01hd037251-05)
- National Center for Research Resources (RR06022)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD 37251)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, insulin pump therapy, multiple daily insulin injections, insulin glargine, insulin aspart, glycemic control, HbA1c, total daily insulin dose, self-monitoring of blood glucose, pediatric diabetes, adolescents
- MeSH terms
- Insulin Glargine, Adolescent, Adult, Child, Diabetes Mellitus, Type 1, Drug Administration Schedule, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Insulin Infusion Systems, Blood Glucose Self-Monitoring, Patient Selection, Postprandial Period, Insulin, Long-Acting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review