Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients

Open access
Plank, Johannes, Blaha, Jan, Cordingley, Jeremy, Wilinska, Malgorzata E., Chassin, Ludovic J., Morgan, Cliff, Squire, Stephen, Haluzik, Martin, Kremen, Jaromir, Svacina, Stepan, Toller, Wolfgang, Plasnik, Andreas, Ellmerer, Martin, Hovorka, Roman, Pieber, Thomas R.·2006·Diabetes Care

Abstract

OBJECTIVE—To evaluate a fully automated algorithm for the establishment of tight glycemic control in critically ill patients and to compare the results with different routine glucose management protocols of three intensive care units (ICUs) across Europe (Graz, Prague, and London). RESEARCH DESIGN AND METHODS—Sixty patients undergoing cardiac surgery (age 67 ± 9 years, BMI 27.7 ± 4.9 kg/m2, 17 women) with postsurgery blood glucose levels >120 mg/dl (6.7 mmol/l) were investigated in three different ICUs (20 per center). Patients were randomized to either blood glucose management (target range 80–110 mg/dl [4.4–6.1 mmol/l]) by the fully automated model predictive control (MPC) algorithm (n = 30, 10 per center) or implemented routine glucose management protocols (n = 30, 10 per center). In all patients, arterial glucose was measured hourly to describe the glucose profile until the end of the ICU stay but for a maximum period of 48 h. RESULTS—Compared with routine protocols, MPC treatment resulted in a significantly higher percentage of time within the target glycemic range (% median [min–max]: 52 [17–92] vs. 19 [0–71]) over 0–24 h (P < 0.01). Improved glycemic control with MPC treatment was confirmed in patients remaining in the ICU for 48 h (0–24 h: 50 [17–71] vs. 21 [4–67], P < 0.05, and 24–48 h: 65 [38–96] vs. 25 [8–79], P < 0.05, for MPC [n = 16] vs. routine protocol [n = 13], respectively). Two hypoglycemic events (<54 mg/dl [3.0 mmol/l]) were observed with routine protocol treatment. No hypoglycemic event occurred with MPC. CONCLUSIONS—The data suggest that the MPC algorithm is safe and effective in controlling glycemia in critically ill postsurgery patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.29.02.06.dc05-1689

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 195

Metadata

Authors
Plank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., Toller, W., Plasnik, A., Ellmerer, M., Hovorka, R., & Pieber, T. R.
Venue
Diabetes Care
Published
2006-02-01
Volume
29
Issue
2
Pages
271-276
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2158435758
Cited by
195
References
5
FWCI
17.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients. https://app.cochat.ai/papers/10.2337/diacare.29.02.06.dc05-1689
The paper
Plank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., Toller, W., Plasnik, A., Ellmerer, M., Hovorka, R., & Pieber, T. R. (2006). Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients. Diabetes Care. https://doi.org/10.2337/diacare.29.02.06.dc05-1689

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.