The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients
Open accessAbstract
OBJECTIVE—To evaluate a fully automated algorithm for the establishment of tight glycemic control in critically ill patients and to compare the results with different routine glucose management protocols of three intensive care units (ICUs) across Europe (Graz, Prague, and London). RESEARCH DESIGN AND METHODS—Sixty patients undergoing cardiac surgery (age 67 ± 9 years, BMI 27.7 ± 4.9 kg/m2, 17 women) with postsurgery blood glucose levels >120 mg/dl (6.7 mmol/l) were investigated in three different ICUs (20 per center). Patients were randomized to either blood glucose management (target range 80–110 mg/dl [4.4–6.1 mmol/l]) by the fully automated model predictive control (MPC) algorithm (n = 30, 10 per center) or implemented routine glucose management protocols (n = 30, 10 per center). In all patients, arterial glucose was measured hourly to describe the glucose profile until the end of the ICU stay but for a maximum period of 48 h. RESULTS—Compared with routine protocols, MPC treatment resulted in a significantly higher percentage of time within the target glycemic range (% median [min–max]: 52 [17–92] vs. 19 [0–71]) over 0–24 h (P < 0.01). Improved glycemic control with MPC treatment was confirmed in patients remaining in the ICU for 48 h (0–24 h: 50 [17–71] vs. 21 [4–67], P < 0.05, and 24–48 h: 65 [38–96] vs. 25 [8–79], P < 0.05, for MPC [n = 16] vs. routine protocol [n = 13], respectively). Two hypoglycemic events (<54 mg/dl [3.0 mmol/l]) were observed with routine protocol treatment. No hypoglycemic event occurred with MPC. CONCLUSIONS—The data suggest that the MPC algorithm is safe and effective in controlling glycemia in critically ill postsurgery patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes
Umpierrez, G. E., Isaacs, S. D., Bazargan, N., You, X., Thaler, L. M., & Kitabchi, A. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8341 · Cited by 2,195
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Malmberg, K., Rydén, L., Efendic, S., Herlitz, J., Nicol, P., Waldenstrom, A., Wedel, H., & Welin, L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00126-k · Cited by 1,560
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationNorhammar, A., Tenerz, Å., Nilsson, G., Hamsten, A., Efendíc, S., Rydén, L., & Malmberg, K. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09089-x · Cited by 1,112
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Nguyen, H. B., Corbett, S. W., Steele, R., Banta, J., Clark, R. T., Hayes, S. R., Edwards, J., Cho, T. W., & Wittlake, W. A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000259463.33848.3d · Cited by 555
Perioperative Glycemic Control: An Evidence-based Review
Lipshutz, A. K. M., Gropper, M. A., Warner, D. S., & Warner, M. A. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181948a80 · Cited by 259
Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J. (2009) · Critical Care · doi:10.1186/cc8129 · Cited by 86
“When evaluating reports of experience with computerized insulin infusion protocols, some have shown improved glycemic control with reduced time-to-target, longer time-in-target and lower rates of hypoglycemia [20, 22-35 ].”
BackgroundTight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82
Self-citation
Metadata
- Authors
- Plank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., Toller, W., Plasnik, A., Ellmerer, M., Hovorka, R., & Pieber, T. R.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2006-02-01
- Volume
- 29
- Issue
- 2
- Pages
- 271-276
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2158435758
- Cited by
- 195
- References
- 5
- FWCI
- 17.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients. https://app.cochat.ai/papers/10.2337/diacare.29.02.06.dc05-1689
- The paper
- Plank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., Toller, W., Plasnik, A., Ellmerer, M., Hovorka, R., & Pieber, T. R. (2006). Multicentric, Randomized, Controlled Trial to Evaluate Blood Glucose Control by the Model Predictive Control Algorithm Versus Routine Glucose Management Protocols in Intensive Care Unit Patients. Diabetes Care. https://doi.org/10.2337/diacare.29.02.06.dc05-1689
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.