The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Evaluating the Implementation of the EndoTool Glycemic Control Software System
Open accessAbstract
Purpose.: The purpose of this study was to compare achievement of glycemic control on insulin drips before and after the implementation of EndoTool, a glucose management software system used in a community hospital setting. Methods.: A retrospective chart review was performed of patients on an insulin drip who were managed before and after implementation of the EndoTool software. Fifty patients were selected for each group. Statistical analyses were run to compare metrics gathered between groups. Results.: Patients in the standard care group were on an insulin drip for an average of 23.9 hours compared to 20.9 hours in the EndoTool group (P = 0.38). Hypoglycemia occurred at an average rate of 0.036 events per patient in the standard group and 0.007 events per patient in the EndoTool group (P = 0.17). The average rate of hyperglycemia was 0.358 events per patient in the standard group and 0.283 events per patient in the EndoTool group (P = 0.25). The average time to achieve the blood glucose target was 2.78 and 3.67 hours in the standard and EndoTool groups, respectively (P = 0.27). Total patient values were within target range 45.2% of the time in the standard care group and 47.3% of the time in the EndoTool group (P = 0.71). Conclusion.: Analysis of the implementation of EndoTool in the community hospital setting found no statistically significant differences between groups, although rates of hypo- and hyperglycemia showed a trend toward improved safety in the EndoTool group. These results could be attributed to the conservative parameters the hospital set in the initial phase of EndoTool implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“most hospitals use institutional-based, nurse-driven protocols, with several validated protocols published.1291–1293”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1293]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes
Umpierrez, G. E., Isaacs, S. D., Bazargan, N., You, X., Thaler, L. M., & Kitabchi, A. E. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.3.8341 · Cited by 2,195
Persistent Hyperglycemia is Predictive of Outcome in Critically Ill Trauma Patients
Bochicchio, G. V., Sung, J., Joshi, M., Bochicchio, K., Johnson, S. B., Meyer, W., & Scalea, T. M. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000162141.26392.07 · Cited by 439
Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J. (2009) · Critical Care · doi:10.1186/cc8129 · Cited by 86 · cited 2×
“In an efficacy study, use of EndoTool resulted in a 46% decrease in the total number of blood glucose measurements taken each month and an overall reduction in the total number of minutes spent by nurses dealing with glucose control issues (6).”
MethodResultFogel, S. L., & Baker, C. C. (2013) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2012.12.015 · Cited by 24 · cited 1×
“Studies have shown that, compared to patients with standard paper protocols, those managed with EndoTool have had a 95% reduction in serious hypoglycemic episodes (defined as blood glucose <40 mg/dL) (5,6).”
ResultHarris, C., & Greene, D. (2009) · Nursing Management · doi:10.1097/01.numa.0000351531.55360.ae · Cited by 4 · cited 1×
“A study evaluating the software with postoperative cardiovascular patients had been published in 2009 (9).”
Glucose Control in the Critically Ill Patient Utilizing Computerized Intravenous Insulin Dosing
Crockett, S. E. (2009) · US Endocrinology · doi:10.17925/use.2009.05.1.45 · Cited by 3 · cited 1×
“As an alternative to such paper protocols, computer-guided glucose management systems are now starting to be used to improve glucose management by reducing insulin infusion calculation errors and standardizing therapy (7).”
MethodCharting a winning course with nursing informatics
Graybeal, K. B. (2009) · Nursing Management · doi:10.1097/01.numa.0000363864.92950.f9 · Cited by 2
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Diabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Sly, B., Russell, A. W., & Sullivan, C. (2022) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104596 · Cited by 36
Ekanayake, P. S., Juang, P. S., & Kulasa, K. M. (2020) · Current Diabetes Reports · doi:10.1007/s11892-020-01364-2 · Cited by 21
Euglycemic diabetic ketoacidosis: The paradox of delayed correction of acidosis
Albert, S. G., Shrestha, E., & Wood, E. M. (2023) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2023.102848 · Cited by 6
Metadata
- Authors
- John, S. M., Waters, K. L., & Jivani, K.
- Affiliations
- Philadelphia College of Osteopathic Medicine (US)
- Gwinnett Medical Center (US)
- Corresponding author
- John, Samuel M.
- ORCID
- John, Samuel M.
- Venue
- Diabetes Spectrum
- Publisher
- American Diabetes Association
- Published
- 2018-02-01
- Volume
- 31
- Issue
- 1
- Pages
- 26-30
- ISSN
- 1040-9165 (ISSN-L)
- 1944-7353
- PMC
- PMC5813319
- OpenAlex
- W2767852176
- Cited by
- 15
- References
- 8
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 4
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes Spectrum (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Digital Commons - PCOM (Philadelphia College of Osteopathic Medicine) (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- glycemic control, hypoglycemia, hyperglycemia, community hospitals, diabetes management, software implementation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating the Implementation of the EndoTool Glycemic Control Software System. https://app.cochat.ai/papers/10.2337/ds16-0061
- The paper
- John, S. M., Waters, K. L., & Jivani, K. (2018). Evaluating the Implementation of the EndoTool Glycemic Control Software System. Diabetes Spectrum. https://doi.org/10.2337/ds16-0061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.