CoChat

Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin

Open access
Antfolk, C, Björkman, A, Frank, S, Sebelius, F, Lundborg, G, Rosen, B · 2012 · Journal of Rehabilitation Medicine
Cited by 113

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Lack of sensory feedback is a drawback in today's hand prostheses. We present here a non-invasive simple sensory feedback system, which provides the user of a prosthetic hand with sensory feedback on the arm stump. It is mediated by air in a closed loop system connecting silicone pads on the prosthetic hand with pads on the amputation stump. The silicone pads in a "tactile display" on the amputation stump expand when their corresponding sensor-bulb in the prosthesis is touched, evoking an experience of "real touch". METHODS: Twelve trans-radial amputees and 20 healthy non-amputees participated in the study. We investigated the capacity of the system to mediate detection of touch, discrimination between different levels of pressure and, on the amputees also, the ability to locate touch. RESULTS: The results showed a median touch threshold of 80 and 60 g in amputees and non-amputees, respectively, and 90% and 80% correct answers, respectively, in discrimination between 2 levels of pressure. The amputees located touch (3 sites) correctly in 96% of trials. CONCLUSION: This simple sensory feedback system has the potential to restore sensory feedback in hand amputees and thus it could be a useful tool to enhance prosthesis use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2340/16501977-1001

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 113

Metadata

Authors
Antfolk, C., Björkman, A., Frank, S., Sebelius, F., Lundborg, G., & Rosen, B.
Venue
Journal of Rehabilitation Medicine
Published
2012
Volume
44
Issue
8
Pages
702-707
ISSN
1650-1977 (ISSN-L)
OpenAlex
W2154760458
Cited by
113
References
5
FWCI
3.31
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. https://app.cochat.ai/papers/10.2340/16501977-1001
The paper
Antfolk, C., Björkman, A., Frank, S., Sebelius, F., Lundborg, G., & Rosen, B. (2012). Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. Journal of Rehabilitation Medicine. https://doi.org/10.2340/16501977-1001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.