Will Two Do? Varying Dimensions in Electrocardiography: The PhysioNet/Computing in Cardiology Challenge 2021
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The PhysioNet/Computing in Cardiology Challenge 2021 focused on the identification of cardiac abnormalities from electrocardiograms (ECGs) and assessed the diagnostic potential of reduced-lead ECGs relative to the standard but less-accessible twelve-lead ECG. We sourced 131,155 recordings with clinical diagnoses from seven institutions in four countries, sharing 88,253 annotated recordings publicly and withholding the remaining recordings for validation and testing. We asked the Challenge participants to design working, open-source algorithms for identifying cardiac abnormalities from twelve-lead, six-lead, four-lead, three-lead, and two-lead ECG recordings. By sourcing data from diverse populations, requiring the submission of reusable training code, and designing an evaluation metric specifically for this task, we encouraged the development of generalizable, reproducible, and clinically relevant algorithms for identifying cardiac abnormalities from ECGs. A total of 68 teams submitted a total of 1056 algorithms during the Challenge. Of these, 39 teams were ultimately successful, representing a diversity of approaches from both academia and industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Heart Disease and Stroke Statistics—2021 Update: A Report From the American Heart Association
Virani, S. S., Alonso, A., Aparicio, H. J., Benjamin, E. J., Bittencourt, M. S., Callaway, C. W., Carson, A. P., Chamberlain, A. M., Cheng, S., Delling, F. N., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000950 · Cited by 5,784 · cited 1×
“Cardiovascular disease is a leading cause of death worldwide, but different cardiovascular diseases have different causes, risks, and treatments [5].”
BackgroundPTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315 · cited 1×
“This database contains 21,837 recordings from the PTB-XL database [14].”
MethodClifford, G., Liu, C., Moody, B., Lehman, L.-W., Silva, I., Li, Q., Johnson, A., & Mark, R. (2017) · Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2017.065-469 · Cited by 838 · cited 6×
“We asked the participants to design and implement working, open-source algorithms to automatically identify any cardiac abnormalities present in twelve-lead, six-lead, four-lead, three-lead, and two-lead ECGs recordings.”
BackgroundInfluentialSelf-citationLiu, F., Liu, C., Zhao, L., Zhang, X., Wu, X., Xu, X., Liu, Y., Ma, C., Wei, S., He, Z., et al. (2018) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2018.2442 · Cited by 620 · cited 1×
“This database contains 13,256 recordings from the China Physiological Signal Challenge (CPSC) 2018 [11].”
MethodA 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients
Zheng, J., Zhang, J., Danioko, S., Yao, H., Guo, H., & Rakovski, C. (2020) · Scientific Data · doi:10.1038/s41597-020-0386-x · Cited by 487 · cited 1×
“This database contains 10,247 recordings from Chapman University and Shaoxing People’s Hospital [15].”
MethodSNOMED clinical terms: overview of the development process and project status.
Stearns, M. Q., Price, C., Spackman, K. A., & Wang, A. Y. (2001) · Europe PMC (PubMed Central) · Cited by 448
Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020
Perez Alday, E. A., Gu, A., J Shah, A., Robichaux, C., Ian Wong, A.-K., Liu, C., Liu, F., Bahrami Rad, A., Elola, A., Seyedi, S., et al. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abc960 · Cited by 436
Self-citationOptimal Multi-Stage Arrhythmia Classification Approach
Zheng, J., Chu, H., Struppa, D., Zhang, J., Yacoub, S. M., El-Askary, H., Chang, A., Ehwerhemuepha, L., Abudayyeh, I., Barrett, A., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-59821-7 · Cited by 198 · cited 1×
“This database contains 34,905 recordings from Ningbo First Hospital [16].”
MethodThe centennial of the einthoven electrocardiogram
Kligfield, P. (2002) · Journal of Electrocardiology · doi:10.1054/jelc.2002.37169 · Cited by 85 · cited 1×
“The standard twelve-lead ECG is a widely used, non-invasive tool for monitoring cardiac function and diagnosing cardiac disorders [6].”
MethodClassification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020
Reyna, M. A., Alday, E. A. P., Gu, A., Liu, C., Seyedi, S. S., Rad, A. B., Elola, A., Li, Q., Sharma, A., & Clifford, G. D. (2020) · Computing in cardiology · doi:10.22489/cinc.2020.236 · Cited by 77
Self-citationDrew, B. J., Pelter, M. M., Brodnick, D. E., Yadav, A. V., Dempel, D., & Adams, M. G. (2002) · Journal of Electrocardiology · doi:10.1054/jelc.2002.37150 · Cited by 76
Aldrich, H. R., Hindman, N. B., Hinohara, T., Jones, M. G., Boswick, J. M., Lee, K. L., Bride, W. M., Califf, R. M., & Wagner, G. S. (1987) · The American Journal of Cardiology · doi:10.1016/s0002-9149(87)80062-0 · Cited by 60
Best leads in the standard electrocardiogram for the emergency detection of acute coronary syndrome
Green, M., Ohlsson, M., Forberg, J. L., Björk, J., Edenbrandt, L., & Ekelund, U. E. G. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.12.011 · Cited by 26 · cited 1×
“Subsets of the standard twelve leads can be comparable to the full set of leads in limited contexts, but there is limited evidence that reduced-lead ECGs can capture the wide range of diagnostic information captured by twelve-lead ECGs [7–9].”
Background
Cited by
Applications of Self-Supervised Learning to Biomedical Signals: A Survey
Pup, F. D., & Atzori, M. (2023) · IEEE Access · doi:10.1109/access.2023.3344531 · Cited by 43
Bias Mitigation in Primary Health Care Artificial Intelligence Models: Scoping Review
Sasseville, M., Ouellet, S., Rhéaume, C., Sahlia, M., Couture, V., Després, P., Paquette, J.-S., Darmon, D., Bergeron, F., & Gagnon, M.-P. (2025) · Journal of Medical Internet Research · doi:10.2196/60269 · Cited by 38
Mehari, T., & Strodthoff, N. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3310989 · Cited by 29
“Going beyond this, we compiled an even larger pretraining dataset, All2021 , which includes the Computing in CardiologyChallenge2021[38]trainingsetaswellasthe CODE test set and comprises in total 89080 samples.”
MethodWeimann, K., & Conrad, T. O. F. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3427787 · Cited by 19
“We use public data released as part of the Phys-ioNet/Computing in Cardiology Challenge 2021 [34], [35], [36].”
Method
Metadata
- Authors
- Reyna, M. A., Sadr, N., Alday, E. A. P., Gu, A., Shah, A. J., Robichaux, C., Rad, A. B., Elola, A., Seyedi, S., Ansari, S., Ghanbari, H., Li, Q., Sharma, A., & Clifford, G. D.
- Venue
- 2021 Computing in Cardiology (CinC)
- Publisher
- IEEE
- Published
- 2021-09-13
- Pages
- 1-4
- ISSN
- 2325-887X (ISSN-L)
- OpenAlex
- W4206135956
- Cited by
- 198
- References
- 14
- FWCI
- 76.34
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.